scholarly journals A new reliable and rapid HPLC method for the simultaneous determination of amoxicillin and sulbactam pivoxil in pharmaceuticals. Application to both assay and dissolution samples

2022 ◽  
Vol 26(1) (26(1)) ◽  
pp. 1140-1152
Author(s):  
Mariela Fernanda RAZUC ◽  
Fernanda Anabel CABRERA ◽  
Mariano Enrique GARRIDO ◽  
María Verónica RAMIREZ RIGO
2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

Author(s):  
Hina Shamshad ◽  
Ali Sayqal ◽  
Jahan Zeb ◽  
Agha Zeeshan Mirza

Abstract A simple, accurate and precise RP-HPLC method was developed for the simultaneous determination of chloroquine, pyrimethamine and cetirizine hydrochloride concentrations in bulk drug and human serum. The assay was performed using a mobile phase of methanol: water (70:30) at pH of 2.8 ± 0.05 on the Purospher C-18 column with UV detection at 230 nm and rosuvastatin used as an internal standard. The retention times observed for chloroquine, pyrimethamine and cetirizine hydrochloride were 3.5, 2.5 and 5.5 minutes, respectively. The method was found to be specific for the assayed drugs showing a linear response in the concentration range of 1–100 μg mL−1 with coefficients of determination values of (r = 0.999). The method was developed and validated according to ICH guidelines. The method was used to monitor the serum samples and was found to be sensitive for therapeutic purposes, showing the potential to be a useful tool for routine analysis in laboratories.


2005 ◽  
Vol 39 (1-2) ◽  
pp. 305-309 ◽  
Author(s):  
Irinel Badea ◽  
Lelia Lazăr ◽  
Dana Moja ◽  
Daniela Nicolescu ◽  
Aurel Tudose

2011 ◽  
Vol 8 (1) ◽  
pp. 340-346 ◽  
Author(s):  
Rajesh M. Kashid ◽  
Santosh G. Singh ◽  
Shrawan Singh

A reversed phase HPLC method that allows the separation and simultaneous determination of the preservatives methyl paraben (M.P.) and propyl paraben (P.P.) is described. The separations were effected by using an initial mobile phase of water: acetonitrile (50:50) on Inertsil C18 to elute P.P. and M.P. The detector wavelength was set at 205 nm. Under these conditions, separation of the two components was achieved in less than 10 min. Analytical characteristics of the separation such as precision, specificity, linear range and reproducibility were evaluated. The developed method was applied for the determination of preservative M.P. and P.P. at concentration of 0.01 mg/mL and 0.1 mg/mL respectively. The method was successfully used for determining both compounds in sucralfate suspension.


Sign in / Sign up

Export Citation Format

Share Document