scholarly journals Grasping force estimation for prosthetic hands via feature extraction of surface EMG

Author(s):  
Lisha Xu ◽  
Gaoke Zhu ◽  
Xiaogang Duan
2013 ◽  
Vol 433-435 ◽  
pp. 85-92
Author(s):  
Xue Feng Li ◽  
Xiao Gang Duan ◽  
Hua Deng

Through the judgment of slip or not, human make proper adjustment to the grasping force and achieve stable manipulations. To reconstruct this function on a prosthetic hands platform, this paper presents a hybrid slip detect algorithm utilizing the PVDF sensor and FSR sensor. Then a reflex force estimation model is built to quantify the reflex force according to the intensity of slip in the reflex control process. Finally, through comparative experiments, the anti-jamming performance of the hybrid slip detect scheme is tested. A fuzzy controller is used to control the applied force and test the whole reflex control system. The results show that the hybrid slip detect scheme can make accurate judgment and has strong anti-jamming capacity; The output of the reflex force estimation model is accordance with the factual case; And as a whole, the grasping ability of prosthetic hand is substantially enhanced.


Sensors ◽  
2019 ◽  
Vol 20 (1) ◽  
pp. 4 ◽  
Author(s):  
Junghoon Park ◽  
Pilwon Heo ◽  
Jung Kim ◽  
Youngjin Na

This paper presents a fingertip grip force sensor based on custom capacitive sensors for glove-type assistive devices with an open-pad structure. The design of the sensor allows using human tactile sensations during grasping and manipulating an object. The proposed sensor can be attached on both sides of the fingertip and measure the force caused by the expansion of the fingertip tissue when a grasping force is applied to the fingertip. The number of measurable degrees of freedom (DoFs) are the two DoFs (flexion and adduction) for the thumb and one DoF (flexion) for the index and middle fingers. The proposed sensor allows the combination with a glove-type assistive device to measure the fingertip force. Calibration was performed for each finger joint angle because the variations in the expansion of the fingertip tissue depend on the joint angles. The root mean square error (RMSE) for fingertip force estimation ranged from 3.75% to 9.71% after calibration, regardless of the finger joint angles or finger posture.


2019 ◽  
Vol 16 (3) ◽  
pp. 455-467 ◽  
Author(s):  
Sanghyun Kim ◽  
Joowan Kim ◽  
Mingon Kim ◽  
Seungyeon Kim ◽  
Jaeheung Park

2013 ◽  
Vol 13 (9) ◽  
pp. 3302-3311 ◽  
Author(s):  
Zhaojie Ju ◽  
Gaoxiang Ouyang ◽  
Marzena Wilamowska-Korsak ◽  
Honghai Liu

2018 ◽  
Vol 271 ◽  
pp. 124-130 ◽  
Author(s):  
Takashi Takizawa ◽  
Takahiro Kanno ◽  
Ryoken Miyazaki ◽  
Kotaro Tadano ◽  
Kenji Kawashima

Sign in / Sign up

Export Citation Format

Share Document