scholarly journals The uncemented bipolar hemiarthroplasty for displaced femoral neck fractures: 6-year follow-up of 171 cases

1991 ◽  
Vol 62 (2) ◽  
pp. 115-120 ◽  
Author(s):  
Søren Overgaard ◽  
Tim Toftgaard Jensen ◽  
Gunnar Bonde ◽  
Niels B. Mossing
2021 ◽  
Vol 15 (5) ◽  
pp. 988-991
Author(s):  
Zamir Hussain Tunioi ◽  
Rizwan Ali Jhatiyal ◽  
M Azeem Akhund ◽  
M Kashif Abbasi ◽  
L Das Maheshwari ◽  
...  

Aim: To evaluate the functional outcome of bipolar hemiarthroplasty in intracapsular fracture neck of femur. Study design: Descriptive cross sectional study. Place and duration of study: Department of Orthopaedic Surgery & Traumatology, Peoples Medical University Hospital, Shaheed Benazir Abad from 1st December 2017 to 31st December 2020. Methodology: Sixty six cases of intracapsular femoral neck fractures with age ranging from 50 year to 75 year of either gender who were ambulatory before injury were included; while basicervical, younger than 50 years, with neuromuscular disorder, unfit for surgery, open fracture, bilateral injuries, osteoarthritis of hip, Rheumatoid, Gouty, pathological fractures, bedridden & who did not give consent for study, were excluded from the study. Functional outcome assessed by Harris hip score & data analyzed by SPSS version 23. Results: Twenty six (59.09%) were male and 40 (40.91%) were female with mean age of 64.3±7.77 year. Average time from injury to hospital arrival was 14.7±6.8 hours. Average time from hospitalization to surgery was 4.67±2.23 days. Average time of surgery was 55.67±9.9 minutes. Average hospital stay was 9.7±4.3 days. The average time of follow-up was 18.45±7.63 months. Conclusion: Bipolar implant is safe, effective, reliable, stable and cost effective implant for intracpsular fracture of femoral neck in elderly populace. The 66.66% of patients have satisfactory Harris hip score in follow up duration of 18.45±7.63 months. Keywords: Functional, Outcome, Femoral neck fractures, FNF, Bipolar, Hemiarthroplasty, HHS


KYAMC Journal ◽  
2017 ◽  
Vol 8 (1) ◽  
pp. 10-14
Author(s):  
Md Ashraful Islam ◽  
Md Abdur Rashid ◽  
Md Rafiqul Islam ◽  
Md Masudar Rahman ◽  
Md Asmaul Hossain Khan ◽  
...  

Background: Femoral neck fractures are common in the elderly population. To avoid the poor outcome of internal fixation and for early mobilization, hemiarthroplasty is performed. However, there is inadequate evidence to support the choice between unipolar or bipolar hemiarthroplasty.Objectives: The aim of this study was to compare the outcome of unipolar with the bipolar prosthesis in geriatric patients.Methods: Forty-one patients above 60 years of age and an acute displaced fracture of the femoral neck were randomly allocated to treatment by either unipolar or bipolar hemiarthroplasty, in the Department of Orthopaedics at Khwaja Yunus Ali Medical College and Hospital, Enayetpur, Sirajgonj, Bangladesh in between December 2014 and February 2017. Functional outcome was assessed and compared using Harris hip score and radiological parameters with a follow-up of one year.Results: The two groups of patients with mean age of 67.3 in bipolar group and 75.6 in unipolar group did not differ in their pre-injury characteristics and perioperative parameters. The mean Harris hip score in bipolar and unipolar groups was 86.18±12.18 and 79.79±15.55, respectively (p=0.183); range of motion was 210.63±28.39 and 181.58±37(p=0.015) with bipolar and unipolar groups, respectively. Functional activities were better in the bipolar group. Complications like painful hip, posterior dislocation, periprosthetic fracture and acetabular erosion were encountered in unipolar prostheses.Conclusion: The use of bipolar endoprosthesis in the management of displaced femoral neck fractures in the elderly was associated with better mean Harris hip score and incidence of complications was limited. Hence, bipolar would be a better option in elderly patients with fracture neck of femur.KYAMC Journal Vol. 8, No.-1, Jul 2017, Page 10-14


Sign in / Sign up

Export Citation Format

Share Document