42 Long, Extensive Common Carotid Artery/Internal Carotid Artery Plaque

2006 ◽  
pp. 202-203
2021 ◽  
pp. 153857442199293
Author(s):  
Constantinos Zarmakoupis ◽  
George Galyfos ◽  
Grigorios Tsoukalos ◽  
Panagiota Dalla ◽  
Alexandra Triantafyllou ◽  
...  

This report aims to present a rare case of a common carotid artery (CCA) pseudoaneurysm with a concomitant internal carotid artery (ICA) stenosis that were treated with a hybrid technique. This strategy included the retrograde placement of a CCA covered stent under ICA clamping followed by standardized carotid endarterectomy. The technique will be discussed and compared with other possible treatments.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
G Goudot ◽  
L Khider ◽  
O Pedreira ◽  
J M Poree ◽  
P Julia ◽  
...  

Abstract Background Carotid plaque vulnerability assessment is an important factor in guiding the decision to treat significant carotid stenosis. Ultrafast Ultrasound Imaging (UF) offers the possibility of evaluating local flow velocities over an entire 2D image, allowing access to velocity measurements in contact with the arterial wall and to measure the wall shear stress (WSS). Purpose To evaluate the feasibility of WSS measurement in a prospective series of patients with carotid stenosis. Methods A 7.5 MHz linear probe of an Aixplorer scanner was used. UF acquisitions had 3 tilted plane waves transmits (−10; 0; 10°) and an effective frame rate of 5000Hz. We evaluated the flow velocity in 5 areas of the carotid wall: common carotid artery (1), plaque ascent (2), plaque peak (3), plaque descent (4), internal carotid artery (5) (Figure). WSS was computed with the vector field speed using the following formula, WSS=μ·δn·v with v the blood velocity, n the normal vector to the vessel wall and μ, the blood viscosity, calculated from the hematocrit value for each patient. WSS measurement method was first validated using a laminar flow phantom and known viscosity. And then, 33 patients were then prospectively evaluated, with a median carotid stenosis degree of 80% [75–85]. Results Significant correlation was found between in vitro measurement and the theoretical WSS values (R2=0.95; p<0.001).In patients,the maximum WSS value over the cardiac cycle follows the shape of the plaque with an increase during the ascend, reaching its maximum value of 3.57 Pa [2.47–4.45] at the peak of the plaque, and a fall after passing the peak (0.99 Pa [0.8–1.32]) lower than the WSS values in the non-stenotic areas (1.55 Pa [1.13–1.90] for the common carotid artery) (Table). Table 1 Wall's area Wall shear stress (Pa) Min Max Delta 1. Common carotid artery 0.14 [0.05–0.27] 1.55 [1.13–1.90] 0.73 [0.55–0.96] 2. Plaque's ascent 0.39 [0.24–0.59] 2.63 [1.89–3.28] 1.20 [0.89–1.79] 3. Plaque's peak 0.60 [0.32–0.89] 3.57 [2.47–4.45] 1.78 [1.44–2.46] 4. Plaque's descent 0.16 [0.13–0.22] 0.99 [0.80–1.32] 0.52 [0.34–0.73] 5. Internal carotid artery 0.17 [0.13–0.35] 1.37 [1.04–1.75] 0.72 [0.50–0.87] Results are median [25th–75th percentile]. Figure 1 Conclusion UF provide reliable WSS values. High WSS was present at the peak of the plaque, whereas lowest WSS values were found at the post-stenotic zone. WSS evaluation may help to better characterize the carotid plaque vulnerability.


2012 ◽  
Vol 18 (3) ◽  
pp. 320-325 ◽  
Author(s):  
S. Toyota ◽  
A. Wakayama ◽  
T. Yoshimine

A 54-year-old man with symptomatic internal carotid artery stenosis with absence of the common carotid artery (CCA), who had been treated with surgery and postoperative radiotherapy for tonsillar carcinoma, underwent direct percutaneous carotid artery stenting (CAS). To our knowledge, this is the first report of direct percutaneous carotid artery stenting (CAS) for a patient with absent CCA.


Ultrasound ◽  
2018 ◽  
Vol 26 (2) ◽  
pp. 101-109 ◽  
Author(s):  
Mervyn Alexander McKenna ◽  
Michelle Clare Bonfield ◽  
Teresa Robinson

Introduction Duplex ultrasound is often the sole imaging modality used in diagnosing carotid artery disease. However, the reproducibility and repeatability of scientists in determining the peak systolic velocity and end diastolic velocity of the internal carotid artery and common carotid artery (CCA) is widely debated. Study aim To investigate intra- and inter-operator variability in diagnostic ultrasound of the carotid arteries across a centralised vascular network using a healthy test subject. To identify potential causes of variability and highlight areas for improvement. Methods Fifteen vascular scientists across four hospital Trusts in the Bristol, Bath and Weston vascular network measured the peak systolic velocity and end diastolic velocity of the internal carotid artery and common carotid artery in a subject using a single portable ultrasound machine. A double blind assessment of spectral Doppler images was performed by two vascular clinical scientists for optimal caliper placement, spectral gain and angle correction. Results were compared for intra- and inter-operator variability. Results Initial quality assessment of the Doppler images revealed that three out of 15 scientists produced suboptimal results. Box plot analysis of the common carotid artery and internal carotid artery for each scientist revealed significant variance (ANOVA p < 0.05). However, a Levene’s test revealed no single operator who consistently produced highly variable results ( p = 0.569). Conclusion This study highlights the difficulty in obtaining consistent velocity measurements from a subject. Despite the variability in absolute peak systolic velocity and end diastolic velocity, scientists were generally consistent in obtaining an optimal spectral Doppler trace. Some issues with consistency were, however, identified which were subsequently addressed.


Sign in / Sign up

Export Citation Format

Share Document