Improvement Of Free Convection From Three horizontal Finned Cylinders Fixed Between Two Walls

2018 ◽  
Vol 6 (2) ◽  
pp. 98-114 ◽  
Author(s):  
Hassan K. Abdullah ◽  
Haneen H. Rahman

Improvement of  free convection heat transfer from three finned cylinders arranged at a triangle shape fixed between two walls has been investigated in this study. Three mild steel finned cylinders fixed between two walls from Pyrex glass have been used as a test rig. It has been changed the spacing between the cylinders (X/D=1,2,3 & S/D=2,4,6) and the head orientation of a triangle to the top under constant heat flux values (38, 254, 660, 1268) W/m2 and compare with case of three finned cylinders arranged in vertical array in line fixed between two wall. The experiments are carried for Rayleigh number (Ra) from (15x103 to 14 x104 ) and Prandtl  number from (0.706-0.714 ). The results indicated an increase in Nu with increasing Ra for all cylinders. Furthermore,hx and Nu increased proportionally with the increasing of cylinder spacings for all heat fluxes. Also the experimental results show the case of triangle arrangement is improvement the heat transfer more than case of vertical arrangement. Heat transfer dimensionless correlating equation is also proposed.              Nomeclature: Ax: surface area(m2), T∞: surrounding temperature(k), D: the outer diameter of fin (m), Kf: the thermal conductivity for air at film temperature(W/m.k), hx: Local convection heat transfer(W/m2.k),  Gravitational acceleration(m/s2), I: Electric current (Amp), Nu: Nusselt number, Pr: Prandtl number

Author(s):  
R. Hosseini ◽  
A. Gholaminejad ◽  
M. Alipour

In the present work, natural convection heat transfer is studied experimentally in a concentric annulus with constant heat flux and stationary outer pipe and rotating and insulated inner pipe. The experimental setup used consisted of an annulus with radius ratio of Ro/Ri = 0.253 and length of 2.2m. Heat fluxes of 58, 96.5, 145 and 193W/m2 were applied to the heater in the present study and surface temperature of the outer pipe is measured at 39 points along its length. Average Nusselt number was plotted versus Taylor number. It is observed that Nusselt number slightly decreases up to Taylor number of 4.5E+5.


1961 ◽  
Vol 83 (1) ◽  
pp. 87-93 ◽  
Author(s):  
Floyd W. Larsen ◽  
James P. Hartnett

Free convection heat transfer to water and to mercury in a circular tube closed at the bottom end, open to a cooled reservoir at the top, and heated through the wall with a uniform heat flux, has been investigated with emphasis on the effect of length-to-radius ratio and tube inclination. Dimensionless wall and fluid temperatures are presented for several tube inclinations over a range of imposed dimensionless heat fluxes to a tube of length-to-radius ratio 14.6; these results are compared to earlier measurements in a tube of length-to-radius ratio 21.0. Over the range of the investigation the flow was apparently in fully mixed turbulent motion, as evidenced by the large fluid temperature fluctuations recorded during the tests. Inclination of the tube was found to result in a considerable decrease in temperature fluctuations and a corresponding increase in heat transfer above that observed with the tube axis vertical.


Sign in / Sign up

Export Citation Format

Share Document