Ultrasonic C-Scan Imaging: Preliminary Evaluation for Corrosion and Void Detection in Posttensioned Tendons

Author(s):  
Shivprakash Iyer ◽  
Andrea J. Schokker ◽  
Sunil K. Sinha

Corrosion of the nation’s transportation infrastructure is a widespread and costly problem. The most prevalent durability issue in reinforced concrete structures is chloride-induced corrosion of the reinforcing steel. A reliable method of determining grout voids and corrosion levels in posttensioned bridge structures is needed. Traditional techniques of corrosion monitoring (e.g., half-cell potential and corrosion rate measurement) are problematic when used in this type of structure, as are standard nondestructive evaluation (NDE) methods, such as impact echo. C-scan imaging, an ultrasonic technique used primarily in the composites industry for detecting delamination, is examined as a method of evaluating grouted posttensioned tendons. This method exhibits many promising qualities: it can be used for internal or external tendons and on metal or plastic ducts; access to only one side of a specimen is required; strong imaging allows easy interpretation of results; the technique poses no risk to users or the environment; and the method has strong potential for development as a handheld field tool. The C-scan technique may be valuable for the investigation of not only posttensioning applications but other types of reinforced concrete structures as well. Results of preliminary investigations on lab specimens indicate that the C-scan technique holds promise. The ultimate goal of the research is to provide a user-friendly, robust system for the NDE of posttensioned tendons for voids, corrosion, and wire breaks. Recommendations for optimal acquisition and processing techniques as well as for the future development of the equipment as a field tool are proposed.

2013 ◽  
Vol 61 (1) ◽  
pp. 32-37 ◽  
Author(s):  
Guofu Qiao ◽  
Yi Hong ◽  
Tiejun Liu ◽  
Jinping Ou

Purpose – The aim of this paper was to investigate the passive corrosion control and active corrosion protective effect of the reinforced concrete structures by electrochemical chloride removal (ECR) method and inhibitors approach, respectively. Design/methodology/approach – The concentration of aggressive chloride ion distributed from the reinforcing steel to the surface of the concrete cover was analyzed during the ECR processes. Besides, the half-cell potential, the concrete resistance R c , the polarization resistance R p and the capacitance of double layer C dl of the steel/concrete system were used to characterize the electrochemical performance of the concrete prisms. Findings – The effectiveness of ECR could be enhanced by increasing the amplitude of potential or prolonging the time. Inhibitor SBT-ZX(I) could successfully prevent the corrosion development of the reinforcing steel in concrete. Originality/value – The research provides the scientific basis for the practical application of ECR and inhibitors in the field.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Ahmed A. Abouhussien ◽  
Assem A. A. Hassan

Reinforced concrete structures, especially those in marine environments, are commonly subjected to high concentrations of chlorides, which eventually leads to corrosion of the embedded reinforcing steel. The total time to corrosion of such structures may be divided into three stages: corrosion initiation, cracking, and damage periods. This paper evaluates, both empirically and experimentally, the expected time to corrosion of reinforced concrete structures. The tested reinforced concrete samples were subjected to ten alternative curing techniques, including hot, cold, and normal temperatures, prior to testing. The corrosion initiation, cracking, and damage periods in this investigation were experimentally monitored by an accelerated corrosion test performed on reinforced concrete samples. Alternatively, the corrosion initiation time for counterpart samples was empirically predicted using Fick’s second law of diffusion for comparison. The results showed that the corrosion initiation periods obtained experimentally were comparable to those obtained empirically. The corrosion initiation was found to occur at the first jump of the current measurement in the accelerated corrosion test which matched the half-cell potential reading of around −350 mV.


2021 ◽  
Vol 302 ◽  
pp. 02018
Author(s):  
Jagadeesh Bhattarai ◽  
Madan Somai ◽  
Nirmal Acharya ◽  
Ajaya Giri ◽  
Akash Roka ◽  
...  

Widespread applications of reinforced concrete structures have been practiced since the 20th century because of their excellent properties despite their early corrosion degradation. For the control of such a problem, a design strategy of corrosion-resistant environments of the reinforced concrete structures is highly desirable for extending of a lifetime. The present research work was focused to investigate the effects of the green plant extract-based inhibitors from Vitex negundo and Catharanthus roseus leaves, and one waterproofing chemical (PtS) for controlling the corrosion susceptibility of concrete rebar using a half-cell potential method following the ASTM C876-91 standard. Both plant extracts have good anti-corrosion properties, and hence could be applied as green concrete additives to increase the corrosion resistance of the steel reinforcing bars. The anti-corrosion performance of the steel rebars in concrete is remarkably higher with the additions of 1000 and 2000 ppm plant extracts than the additions of waterproofing chemicals used, based on the shifting of corrosion potential (ϕcorr.) values to a more positive direction than −126 mV (SCE). The results agreed that both the plant extracts could be promising for the formulation of effective, ecofriendly anti-corrosion additives to delay the corrosion susceptibility of the concrete infrastructures.


Sign in / Sign up

Export Citation Format

Share Document