Principles of combining start signals of a set of fault detectors or measuring units of relay protection to increase its sensitivity

Author(s):  
M. Sharygin ◽  
2019 ◽  
Vol 139 ◽  
pp. 01060 ◽  
Author(s):  
Anton Loskutov ◽  
Pavel Pelevin ◽  
Mile Mitrovoc

The issues of increasing the sensitivity and reliability of multi-parameter relay protection by sharing more than one information feature (current module, voltage module and phase, active and reactive power) are considered. In this case, the response parameters of individual one-dimensional measuring fault detectors based on the accumulation of statistical data during simulation in the Matlab / Similink software package are determined. A method for combining the signals of one-dimensional measuring fault detectors to increase the sensitivity of protection is proposed. The reliability of the organization of the logical part of multi-parameter relay protection was estimated using the theory of Markov processes, the principles of “2 out of 3” and “1 out of 2”.


Author(s):  
Aleksandr S. Serebryakov ◽  
Vladimir L. Osokin ◽  
Sergey A. Kapustkin

The article describes main provisions and relations for calculating short-circuit currents and phase currents in a three-phase traction transformer with a star-triangle-11 connection of windings, which feeds two single-phase loads in AC traction networks with a nominal voltage of 25 kilovolts. These transformers provide power to the enterprises of the agro-industrial complex located along the railway line. (Research purpose) The research purpose is in substantiating theoretical equations for digital intelligent relay protection in two-phase short circuits. (Materials and methods) It was found that since the sum of instantaneous currents in each phase is zero, each phase of the transformer works independently. We found that this significantly simplifies the task of analyzing processes with a two-phase short circuit. In this case, the problem of calculating short-circuit currents in the traction network can be simplified by reducing it to the calculation of an ordinary electric circuit with three unknown currents. (Results and discussion) The article describes equations for calculating short-circuit resistances for one phase of the transformer when connecting the secondary winding as a star or a triangle. The currents in the phases of the transformer winding at short circuit for the star-triangle-11 and star-star-with-ground schemes are compared. It was found that when calculating short-circuit currents, there is no need to convert the secondary winding of the traction transformer from a triangle to a star. (Conclusions) It was found that the results of the research can be used in the transition of relay protection systems from electromagnetic relays to modern high-speed digital devices, which will increase the operational reliability of power supply systems for traction and non-traction power consumers.


Sign in / Sign up

Export Citation Format

Share Document