scholarly journals Research Regarding Analysis of the Target Safety Standard for Fire Resistance Design and its Mode of Expression - Estimation for the Safety Standard Targeted by the Verification Method for Fire Resistance Performance - Chapter 6 Variations of the Design Fire Source and Fire Behavior of Fully-Developed Fires

2008 ◽  
Vol 27 (3) ◽  
pp. 436-456 ◽  
Author(s):  
Akiko Natori
2012 ◽  
Vol 446-449 ◽  
pp. 1103-1108
Author(s):  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
Soo Young Park

Composite beam using asymmetric H-shaped steel is one of the constructional structures developed in the advanced countries in Europe since early 1990s. The purpose of this study on composite beams where H-shaped steel is partially laid in concrete slabs was to find how to design fire protection and improve fire-resistance to make deep deck plates provide the beams with advantages upon a fire and to improve stiffness in structural aspect. Only lower flange which is directly exposed to a fire was included in fire-resistance design in order to decide optimal fire- protection design condition and test was conducted for spray-coating and paint-coating. In the fire resistance test, web thickness and lower flange thickness were varied to derive the optimum condition for improving fire-resistance performance. It was observed from the test that 90-minute-protection employed to lower flange provided fire resistance for 3 hours. It was also observed that the basic shape resisted fire for 89 minutes, while web reinforcement and lower flange reinforcement provided fire-resistance for 112 and 157 minutes, respectively. The result showed that lower flange reinforcement is the most effective way to improve fire-resistance.


2012 ◽  
Vol 446-449 ◽  
pp. 1298-1306
Author(s):  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
In Hwan Yeo

The temperature of the steel tube of a CFT column rises rapidly upon a fire causing the deterioration of its strength, while the concrete inside of the tube having large heat capacity provides fire-resistance performance. In order to employ CFT columns as fire-resistant structure, it is necessary to conduct studies on the factors exerting influence on structural capacities and the influence associated with each condition. Concrete’s compressive strength, cross-sectional size, axial load ratio and boundary condition are the major factors which are influential in fire-resistance performance. In particular, boundary condition between columns and beams is one of the major factors which decide fire-resistance performance because it exerts influence on load carrying capacity. The result of the test conducted in this study showed that fire-resistance time of 106 minutes was secured in the specimens with clamped ends and that of 89 minutes in those with pinned ends when cross-sectional size was 360 by 360. In the specimens with cross-sectional size of 280 x 280, fire-resistance time of 113 minutes was secured under the condition of clamped ends and that of 78 minutes was secured under the condition of pinned ends.


2011 ◽  
Vol 82 ◽  
pp. 752-757 ◽  
Author(s):  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
Soo Young Park

Composite beam using asymmetric H-shaped steel is one of the constructional structures developed in the advanced countries in Europe since early 1990s. The purpose of this study on composite beams where H-shaped steel is partially laid in concrete slabs was to find how to design fire protection and improve fire-resistance to make deep deck plates provide the beams with advantages upon a fire and to improve stiffness in structural aspect. Only lower flange which is directly exposed to a fire was included in fire-resistance design in order to decide optimal fire- protection design condition and test was conducted for spray-coating and paint-coating. In the fire resistance test, web thickness and lower flange thickness were varied to derive the optimum condition for improving fire-resistance performance. It was observed from the test that 90-minute-protection employed to lower flange provided fire resistance for 3 hours. It was also observed that the basic shape resisted fire for 89 minutes, while web reinforcement and lower flange reinforcement provided fire-resistance for 112 and 157 minutes, respectively. The result showed that lower flange reinforcement is the most effective way to improve fire-resistance.


Sign in / Sign up

Export Citation Format

Share Document