scholarly journals Effect of an External Urinary Collection Device on Catheter Associated Urinary Tract Infections in Hospitalized Women

Author(s):  
Lindsey Rearigh ◽  
Gayle Gillett ◽  
Adrienne Sy ◽  
Terry Micheels ◽  
Luana Evans ◽  
...  

Abstract External urinary collection devices (EUCDs) may reduce indwelling catheter usage and catheter-associated urinary tract infections (CAUTIs). In this retrospective quasi-experimental study, we demonstrated that EUCD implementation in women was associated with significantly decreased indwelling catheter usage and a trend (P = .10) toward decreased CAUTI per 1,000 patient days.


2020 ◽  
Vol 41 (S1) ◽  
pp. s199-s199
Author(s):  
Lindsey Rearigh ◽  
Mark Rupp ◽  
Trevor Craig Van Schooneveld ◽  
Gayle Gillett ◽  
Adrienne Sy ◽  
...  

Background: Catheter-associated urinary tract infections (CAUTIs) are a common hospital-acquired infection (HAI) resulting in excess morbidity, mortality, and cost. Urine management can be a challenging issue, particularly in women, due to limited options for control of urinary incontinence. Issues with urinary leakage and worry for subsequent skin break down often leads to indwelling catheter insertion. In the spring of 2018, our facility implemented a female external urine collection device (EUCD) in efforts to decrease catheter days and to limit CAUTIs. Methods: Retrospective, 32-month (January 2017–August 2019), quasi-experimental, before-and-after study. Catheter use and CAUTI were defined according to CDC NHSN criteria. Poisson regression was used to model the rate of CAUTI (per 1,000 patient days [PD] and per 1,000 catheter days [CD]) comparing the 14 months prior to EUCD introduction with the 14 months after introduction and allowing a 3-month introduction period. Results: The CAUTI rate did not change significantly. The overall CAUTI rate per 1,000 PD decreased slightly from 0.24 to 0.20 (P = 0.44; model risk, 0.86; 95% CI, 0.58–1.26) whereas the rate per 1,000 CD increased slightly 1.5 to 1.6 (P = 0.76; model risk, 1.06; 95% CI, 0.73-–1.56). The CAUTI rate for men increased from 0.09 to 0.11 per 1,000 PD (P = 0.42; model risk, 1.29) and from 0.99 to 1.55 per 1,000 CD (P = 0.17; model risk, 1.56). For women, the rate of CAUTI decreased from 0.15 to 0.09 per 1,000 PD (P = 0.10; model risk, 0.61) and from 2.12 to 1.65 per 1,000 CD (P = 0.38; model risk, 0.38). A significant decrease in catheter days (CD per 1,000 PD; P < .0001) was observed for all hospitalized patients (from 158.56 to 128.3; model risk, 0.81), for men (from 87.06 to 72.15; model risk, 0.83), and for women (from 71.49 to 56.15; model risk, 0.79). Of 2,347 adverse events, 5 (0.2%) involved perineal skin breakdown and redness. Three events were related to malposition of the ECUD or inappropriate level of suction and 1 event was related to latex allergy and EUCD use. Conclusions: The introduction of a EUCD for women was associated with a significant decrease in indwelling catheter usage. A trend toward a decrease in CAUTI per 1,000 PD for women was observed (P = .10). Additional studies on whether the EUCD is associated with changes in UTI rates (both CAUTIs and noncatheter UTIs) as well as cost implications of EUCD are warranted.Funding: NoneDisclosures: None


2004 ◽  
Vol 171 (4S) ◽  
pp. 24-24 ◽  
Author(s):  
Nabi Ghulam ◽  
Sze M. Yong ◽  
Eng Ong ◽  
Adrian Grant ◽  
Gladys C. McPherson ◽  
...  

2004 ◽  
Vol 171 (4S) ◽  
pp. 23-24
Author(s):  
Jay Khastgir ◽  
Mark Mantle ◽  
Andrew Dickinson

Sign in / Sign up

Export Citation Format

Share Document