scholarly journals Spatial Correlation of Flow Induced Temperature Gradients During Tissue Heating with Vascular Geometry using CT Angiography: Implications for Thermal Therapy

2021 ◽  
Author(s):  
Michael C. Kolios ◽  
Michael D. Sherar ◽  
A. E. Worthington ◽  
D. W. Holdsworth ◽  
J. W. Hunt

Spatial Correlation of Flow Induced Temperature Gradients During Tissue Heating with Vascular Geometry using CT Angiography: Implications for Thermal Therapy

2021 ◽  
Author(s):  
Michael C. Kolios ◽  
Michael D. Sherar ◽  
A. E. Worthington ◽  
D. W. Holdsworth ◽  
J. W. Hunt

Spatial Correlation of Flow Induced Temperature Gradients During Tissue Heating with Vascular Geometry using CT Angiography: Implications for Thermal Therapy


1999 ◽  
Vol 44 (6) ◽  
pp. 1479-1497 ◽  
Author(s):  
Michael C Kolios ◽  
Arthur E Worthington ◽  
David W Holdsworth ◽  
Michael D Sherar ◽  
John W Hunt

2006 ◽  
Vol 175 (4S) ◽  
pp. 554-554
Author(s):  
Lori B. Schlunt ◽  
Jonathan D. Harper ◽  
Dale R. Broome ◽  
Greg Watkins ◽  
Pedro W. Baron ◽  
...  

2010 ◽  
Vol 43 (12) ◽  
pp. 16
Author(s):  
WILLIAM E. GOLDEN ◽  
ROBERT H. HOPKINS
Keyword(s):  

VASA ◽  
2005 ◽  
Vol 34 (4) ◽  
pp. 255-261 ◽  
Author(s):  
Diehm ◽  
Baumgartner ◽  
Silvestro ◽  
Herrmann ◽  
Triller ◽  
...  

Background: Open surgical or endovascular abdominal aortic aneurysm (AAA) relies on precise preprocedual imaging. Purpose of this study was to assess inter- and intraobserver variation of software-supported automated and manual multi row detector CT angiography (MDCTA) in aortoiliac diameter measurements before AAA repair. Patients and methods: Thirty original MDCTA data sets (4 times 2mm collimation) of patients scheduled for endovascular AAA repair were studied on a dedicated software capable of creating two-dimensional reformatted planes orthogonal to the aortoiliac center-line. Measurements were performed twice with a four-week interval between readings. Data were analysed by two blinded readers at random order. Two different measurement methods were performed: reader-assisted freehand wall-to-wall measurement and semi-automatic measurement. Results: Aortoiliac diameters were significantly underestimated by the semi-automatic method as compared to reader-assisted measurements (p < 0.0031). Intraobserver variability of AAA diameter calculation was not significant (p > 0.15) for reader-assisted measurements except for the diameter of the left common iliac artery in reader 2 (p = 0.0045) and it was not significant (p > 0.14) using the semi-automatic method. Interobserver variability was not significant for AAA diameter measurements using the reader-assisted method and for proximal neck analysis with the semi-automatic method (p > 0.27). Relevant interobserver variation was observed for semi-automatic measurement of maximum AAA (p = 0.0007) and iliac artery diameters (p = 0.024). Conclusions: Dedicated MDCTA software provides a useful tool to minimize aortoiliac diameter measurement variation and to improve imaging precision before AAA repair. For reliable AAA diameter analysis the reader-assisted freehand measurement method is recommended to be applied to a set of reformatted CT data as provided by the software used in this study.


Sign in / Sign up

Export Citation Format

Share Document