scholarly journals Maximum deflection of symmetric wall-frame buildings

2013 ◽  
Vol 57 (2) ◽  
pp. 173
Author(s):  
Károly A. Zalka

Currently, prefabricated reinforced concrete structures are widely used for the construction of buildings of various functional purposes. In this regard, has been developed SP 356.1325800.2017 "Frame Reinforced Concrete Prefabricated Structures of Multi-Storey Buildings. Design Rules", which establishes requirements for the calculation and design of precast reinforced concrete structures of frame buildings of heavy, fine-grained and lightweight structural concrete for buildings with a height of not more than 75 m. The structure of the set of rules consists of eight sections and one annex. The document reviewed covers the design of multi-story framed beam structural systems, the elements of which are connected in a spatial system with rigid (partially compliant) or hinged joints and concreting of the joints between the surfaces of the abutting precast elements. The classification of structural schemes of building frames, which according to the method of accommodation of horizontal loads are divided into bracing, rigid frame bracing and framework, is presented. The list of structural elements, such as foundations, columns, crossbars, ribbed and hollow floor slabs and coatings, stiffness elements and external enclosing structures is given; detailed instructions for their design are provided. The scope of the developed set of rules includes all natural and climatic zones of the Russian Federation, except seismic areas with 7 or more points, as well as permafrost zones.


2019 ◽  
Vol 97 ◽  
pp. 04022
Author(s):  
Nikolay Trekin ◽  
Emil Kodysh ◽  
Alexander Bybka ◽  
Alexander Yamalov ◽  
Nikita Konkov

The article provides an analysis and justification of the need to take into account the compliance of discs of overlapping and coatings when calculating frames from precast concrete structures. Previously conducted full-scale experiments showed that the rigidity of the precast overlapping with full filling of the seams, in comparison with the monolithic overlapping, decreases by 3-15 times due to the ductility of the joints. The use of refined computational models of structural solutions for frames, which take into account the compliance of the conjugations of elements, makes it possible to trace possible redistribution of efforts. Such an approach when reconstructing, it is possible to optimally select and calculate the enforcement of structure, and on new designing, to increase reliability and / or improve the economic performance of frame buildings. According to the results of analytical studies, formulas were adopted for the parameters that allow one to take into account the overall compliance of overlapping disks and coatings in computational models of building frames. Numerical studies on the computational model of a frame building made it possible to evaluate the effect of accounting for compliance on the stress-strain state of a multi-storey frame.


2021 ◽  
pp. 875529302098801
Author(s):  
Orlando Arroyo ◽  
Abbie Liel ◽  
Sergio Gutiérrez

Reinforced concrete (RC) frame buildings are a widely used structural system around the world. These buildings are customarily designed through standard code-based procedures, which are well-suited to the workflow of design offices. However, these procedures typically do not aim for or achieve seismic performance higher than code minimum objectives. This article proposes a practical design method that improves the seismic performance of bare RC frame buildings, using only information available from elastic structural analysis conducted in standard code-based design. Four buildings were designed using the proposed method and the prescriptive approach of design codes, and their seismic performance is evaluated using three-dimensional nonlinear (fiber) models. The findings show that the seismic performance is improved with the proposed method, with reductions in the collapse fragility, higher deformation capacity, and greater overstrength. Furthermore, an economic analysis for a six-story building shows that these improvements come with only a 2% increase in the material bill, suggesting that the proposed method is compatible with current project budgets as well as design workflow. The authors also provide mathematical justification of the method.


2020 ◽  
Vol 139 ◽  
pp. 103527 ◽  
Author(s):  
Aydin Shishegaran ◽  
Mohammad Reza Khalili ◽  
Behnam Karami ◽  
Timon Rabczuk ◽  
Arshia Shishegaran

Sign in / Sign up

Export Citation Format

Share Document