scholarly journals Indirect Reference Intervals Estimated from Hospitalized Population for Thyrotropin and Free Thyroxine

2010 ◽  
Vol 51 (2) ◽  
pp. 124-130 ◽  
Author(s):  
Tamer C. Inal ◽  
Mustafa Serteser ◽  
Abdurrahman Coşkun ◽  
Aysel Özpinar ◽  
Ibrahim Ünsal
2021 ◽  
Vol 53 (04) ◽  
pp. 272-279
Author(s):  
Chaochao Ma ◽  
Xiaoqi Li ◽  
Lixin Liu ◽  
Xinqi Cheng ◽  
Fang Xue ◽  
...  

AbstractThyroid hormone reference intervals are crucial for diagnosing and monitoring thyroid dysfunction during early pregnancy, and the dynamic change trend of thyroid hormones during pregnancy can assist clinicians to assess the thyroid function of pregnant women. This study aims to establish early pregnancy related thyroid hormones models and reference intervals for pregnant women. We established two derived databases: derived database* and derived database#. Reference individuals in database* were used to establish gestational age-specific reference intervals for thyroid hormones and early pregnancy related thyroid hormones models for pregnant women. Individuals in database# were apparently healthy non-pregnant women. The thyroid hormones levels of individuals in database# were compared with that of individuals in database* using nonparametric methods and the comparative confidence interval method. The differences in thyroid stimulating hormone and free thyroxine between early pregnant and non-pregnant women were statistically significant (p<0.0001). The reference intervals of thyroid stimulating hormone, free thyroxine and free triiodothyronine for early pregnant women were 0.052–3.393 μIU/ml, 1.01–1.54 ng/dl, and 2.51–3.66 pg/ml, respectively. Results concerning thyroid stimulating hormone and free thyroxine reference intervals of early pregnancy are comparable with those from other studies using the same detection platform. Early pregnancy related thyroid hormones models showed various change patterns with gestational age for thyroid hormones. Early pregnancy related thyroid hormones models and reference intervals for pregnant women were established, so as to provide accurate and reliable reference basis for the diagnosing and monitoring of maternal thyroid disfunction in early pregnancy.


Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 45
Author(s):  
Fanwen Meng ◽  
Jacqueline Jonklaas ◽  
Melvin Khee-Shing Leow

Clinicians often encounter thyroid function tests (TFT) comprising serum/plasma free thyroxine (FT4) and thyroid stimulating hormone (TSH) measured using different assay platforms during the course of follow-up evaluations which complicates reliable comparison and interpretation of TFT changes. Although interconversion between concentration units is straightforward, the validity of interconversion of FT4/TSH values from one assay platform to another with different reference intervals remains questionable. This study aims to establish an accurate and reliable methodology of interconverting FT4 by any laboratory to an equivalent FT4 value scaled to a reference range of interest via linear transformation methods. As a proof-of-concept, FT4 was simultaneously assayed by direct analog immunoassay, tandem mass spectrometry and equilibrium dialysis. Both linear and piecewise linear transformations proved relatively accurate for FT4 inter-scale conversion. Linear transformation performs better when FT4 are converted from a more accurate to a less accurate assay platform. The converse is true, whereby piecewise linear transformation is superior to linear transformation when converting values from a less accurate method to a more robust assay platform. Such transformations can potentially apply to other biochemical analytes scale conversions, including TSH. This aids interpretation of TFT trends while monitoring the treatment of patients with thyroid disorders.


2021 ◽  
Author(s):  
K Aaron Geno ◽  
Matthew S Reed ◽  
Mark A Cervinski ◽  
Robert D Nerenz

Abstract Introduction Automated free thyroxine (FT4) immunoassays are widely available, but professional guidelines discourage their use in pregnant women due to theoretical under-recoveries attributed to increased thyroid hormone binding capacity and instead advocate the use of total T4 (TT4) or free thyroxine index (FTI). The impact of this recommendation on the classification of thyroid status in apparently euthyroid pregnant patients was evaluated. Methods After excluding specimens with thyroid autoantibody concentrations above reference limits, thyroid-stimulating hormone (TSH), FT4, TT4, and T-uptake were measured on the Roche Cobas® platform in remnant clinical specimens from at least 147 nonpregnant women of childbearing age and pregnant women at each trimester. Split-sample comparisons of FT4 as measured by the Cobas and equilibrium dialysis were performed. Results FT4 decreased with advancing gestational age by both immunoassay and equilibrium dialysis. TSH declined during the first trimester, remained constant in the second, and increased throughout the third, peaking just before delivery. Interpretation of TT4 concentrations using 1.5-times the nonpregnant reference interval classified 13.6% of first trimester specimens below the lower reference limit despite TSH concentrations within trimester-specific reference intervals. Five FTI results from 480 pregnant individuals (about 1.0%) fell outside the manufacturer’s reference interval. Conclusions Indirect FT4 immunoassay results interpreted in the context of trimester-specific reference intervals provide a practical and viable alternative to TT4 or FTI. Declining FT4 and increasing TSH concentrations near term suggest that declining FT4 is not an analytical artifact but represents a true physiological change in preparation for labor and delivery.


2009 ◽  
Vol 42 (7-8) ◽  
pp. 750-753 ◽  
Author(s):  
Rechelle Silvio ◽  
Karly J. Swapp ◽  
Sonia L. La'ulu ◽  
Kara Hansen-Suchy ◽  
William L. Roberts

Author(s):  
George M. Ziegler ◽  
Jonathan L. Slaughter ◽  
Monika Chaudhari ◽  
Herveen Singh ◽  
Pablo J. Sánchez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document