scholarly journals Agreement between Scheimpflug camera and the swept-source optical coherence tomography measurements in keratometry and higher-order aberrations

Author(s):  
Yujin Gim ◽  
Roo Min Jun ◽  
Kyung Eun Han
Cornea ◽  
2020 ◽  
Vol 39 (7) ◽  
pp. 818-822 ◽  
Author(s):  
Ting Zhang ◽  
Yijing Zhou ◽  
Charlotte Aimee Young ◽  
Aiming Chen ◽  
Guangming Jin ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (7) ◽  
pp. e0254832
Author(s):  
Alexander Buckenham Boyle ◽  
Soobin Namkung ◽  
William Shew ◽  
Akilesh Gokul ◽  
Charles N. J. McGhee ◽  
...  

Purpose To assess the agreement and repeatability of horizontal visible iris diameter (HVID) or white-to-white (WTW) measurements between four imaging modalities; combination slit scanning elevation/Placido tomography, infrared biometry, dual rotating scheimpflug camera/Placido tomography, and swept source anterior segment optical coherence tomography (AS-OCT). Methods A prospective study of 35 right eyes of healthy volunteers were evaluated using the Orbscan IIz, IOL Master 700, Galilei G2, and DRI Triton OCT devices. The inter-device agreement and repeatability of HVID/WTW measurements for each device were analysed. Results Mean HVID/WTW values obtained by the Orbscan IIz, IOL Master 700, Galilei G2 and DRI Triton OCT were 11.77 ± 0.40 mm, 12.40 ± 0.43 mm, 12.25 ± 0.42 mm, and 12.42 ± 0.47 mm, respectively. All pairwise comparisons revealed statistically significant differences in mean HVID/WTW measurements (p = <0.01) except for the IOL Master 700—DRI OCT Triton pair (p = 0.56). Mean differences showed that the DRI Triton OCT produced the highest HVID/WTW values, followed by the IOL Master 700, Galilei G2 and Orbscan IIz, respectively. The limits of agreement were large on all device pairs. There was high repeatability for all devices (ICC ≥ 0.980). The highest repeatability was seen in the Galilei G2 (ICC = 0.995) and lowest in the Orbscan IIz (ICC = 0.980). Conclusions The four devices exhibit high repeatability, but should not be used interchangeably for HVID/WTW measurements in clinical practice.


2020 ◽  
Vol 10 (14) ◽  
pp. 4936
Author(s):  
Pingping Jia ◽  
Hong Zhao ◽  
Yuwei Qin

A high-speed, high-resolution swept-source optical coherence tomography (SS-OCT) is presented for focusing lens imaging and a k-domain uniform algorithm is adopted to find the wave number phase equalization. The radius of curvature of the laser focusing lens was obtained using a curve-fitting algorithm. The experimental results demonstrate that the measuring accuracy of the proposed SS-OCT system is higher than the laser confocal microscope. The SS-OCT system has great potential for surface topography measurement and defect inspection of the focusing lens.