scholarly journals A Novel Pulmonary Valve Replacement Surgery Strategy Using Contracting Band for Patients With Repaired Tetralogy of Fallot: An MRI-Based Multipatient Modeling Study

Author(s):  
Han Yu ◽  
Pedro J. del Nido ◽  
Tal Geva ◽  
Chun Yang ◽  
Zheyang Wu ◽  
...  

Patients with repaired Tetralogy of Fallot (ToF), a congenital heart defect which includes a ventricular septal defect and severe right ventricular outflow obstruction, account for the majority of cases with late-onset right ventricle (RV) failure. Current surgery procedures, including pulmonary valve replacement (PVR) with right ventricle remodeling, yield mixed results. PVR with active band insertion was hypothesized to be of clinical usage on improving RV function measured by ejection fraction (EF). In lieu of risky open-heart surgeries and experiments on animal and human, computational biomechanical models were adapted to study the impact of PVR with five band insertion options. Cardiac magnetic resonance (CMR) images were acquired from seven TOF patients before PVR surgery for model construction. For each patient, five different surgery plans combined with passive and active contraction band with contraction ratio of 20, 15, and 10% were studied. Those five plans include three single-band plans with different band locations; one plan with two bands, and one plan with three bands. Including the seven no-band models, 147 computational bi-ventricle models were constructed to simulate RV cardiac functions and identify optimal band plans. Patient variations with different band plans were investigated. Surgery plan with three active contraction bands and band active contraction ratio of 20% had the best performance on improving RV function. The mean ± SD RV ejection fraction value from the seven patients was 42.90 ± 5.68%, presenting a 4.19% absolute improvement or a 10.82% relative improvement, when compared with the baseline models (38.71 ± 5.73%, p = 0.016). The EF improvements from the seven patients varied from 2.87 to 6.01%. Surgical procedures using active contraction bands have great potential to improve RV function measured by ejection fraction for patients with repaired ToF. It is possible to have higher right ventricle ejection fraction improvement with more bands and higher band active contraction ratio. Our findings with computational models need to be further validated by animal experiments before clinical trial could become possible.

Author(s):  
Yuji Tominaga ◽  
Masaki Taira ◽  
Takashi Kido ◽  
Tomomitsu Kanaya ◽  
Kanta Araki ◽  
...  

Abstract OBJECTIVES The clinical significance of persistent end-diastolic forward flow (EDFF) after pulmonary valve replacement (PVR) remains unclear in patients with repaired tetralogy of Fallot. This study aimed to identify the characteristics of these patients and the impact of persistent EDFF on outcomes. METHODS Of 46 consecutive patients who underwent PVR for moderate to severe pulmonary regurgitation between 2003 and 2019, 23 (50%) did not show EDFF before PVR [group (−)]. In the remaining 23 patients with EDFF before PVR, EDFF was diminished after PVR in 13 (28%) [group (+, −)] and persisted in 10 (22%) [group (+, +)]. The following variables were compared between these 3 groups: (i) preoperative right ventricular (RV) and right atrial volumes measured by magnetic resonance imaging, haemodynamic parameters measured by cardiac catheterization and the degree of RV myocardial fibrosis measured by RV biopsy obtained at PVR and (ii) the post-PVR course, development of atrial arrhythmia and need for intervention. RESULTS A high RV end-diastolic pressure, a greater right atrial volume index and a greater RV end-systolic volume index before PVR and a high degree of RV fibrosis were significantly associated with persistent EDFF 1 year after PVR. Persistent EDFF was a significant risk factor for postoperative atrial tachyarrhythmia, and catheter ablation and pacemaker implantation were required more frequently in these patients. CONCLUSIONS Persistent EDFF after PVR could predict a worse prognosis, especially an increased risk of arrhythmia. Close follow-up is required in patients with persistent EDFF for early detection of arrhythmia and prompt reintervention if necessary. Clinical trial registration number Institutional review board of Osaka University Hospital, number 16105


2021 ◽  
Vol 12 (5) ◽  
pp. 616-627
Author(s):  
Alqasem Fuad H. Al Mosa ◽  
Sreenath Madathil ◽  
Pierre-Luc Bernier ◽  
Christo Tchervenkov

Background: Late pulmonary valve replacement following repair of tetralogy of Fallot may become necessary in patients with chronic pulmonary insufficiency. There is limited information on the long-term outcome of these prostheses, which is the focus of this study. Methods: We conducted a retrospective study of patients with repaired tetralogy of Fallot who underwent pulmonary valve replacement from 1990 to 2015 in our institution. We investigated imaging and clinical parameters including mortality and late adverse events (reintervention [surgical or transcatheter]), infective endocarditis, or arrhythmias requiring device implantation or ablation. Results: There were 69 patients divided into 3 groups: Carpentier-Edwards (n = 14), Contegra (n = 40), and pulmonary homograft (n = 15). The mean age at the time of pulmonary valve replacement was 21 ± 12 years. The mean follow-up was 8.5 ± 4.7 years. The mean preoperative and postoperative right ventricular end-diastolic volume index was 210 ± 42 and 120 ± 24 mL/m2, respectively. There were no mortalities. Late adverse events were observed in 23 (33%) patients: 15 (22%) reintervention (surgical or transcatheter), 11 (16%) endocarditis, and 11 (16%) arrhythmias. Overall, 1-, 5-, and 10-year freedom from surgical reintervention was 98.5%, 93.6%, and 79.3%, respectively. The Contegra group had significantly higher pulmonary valve gradients, a higher risk of developing late adverse events compared to Carpentier-Edwards ( P = .046) and pulmonary homograft ( P = .055) in multivariate analysis and increased risk for reintervention in the univariate analysis (hazard ratio: 3.4; 95% CI: 0.92-13; P value.066). Conclusion: Pulmonary valve replacement in patients with repaired tetralogy of Fallot has acceptable short- and intermediate-term outcomes. Contegra prosthesis had a higher risk of late adverse events with higher pulmonary valve gradients.


Sign in / Sign up

Export Citation Format

Share Document