scholarly journals Sequential Coupling Shows Minor Effects of Fluid Dynamics on Myocardial Deformation in a Realistic Whole-Heart Model

2021 ◽  
Vol 8 ◽  
Author(s):  
Jochen Brenneisen ◽  
Anna Daub ◽  
Tobias Gerach ◽  
Ekaterina Kovacheva ◽  
Larissa Huetter ◽  
...  

Background: The human heart is a masterpiece of the highest complexity coordinating multi-physics aspects on a multi-scale range. Thus, modeling the cardiac function in silico to reproduce physiological characteristics and diseases remains challenging. Especially the complex simulation of the blood's hemodynamics and its interaction with the myocardial tissue requires a high accuracy of the underlying computational models and solvers. These demanding aspects make whole-heart fully-coupled simulations computationally highly expensive and call for simpler but still accurate models. While the mechanical deformation during the heart cycle drives the blood flow, less is known about the feedback of the blood flow onto the myocardial tissue.Methods and Results: To solve the fluid-structure interaction problem, we suggest a cycle-to-cycle coupling of the structural deformation and the fluid dynamics. In a first step, the displacement of the endocardial wall in the mechanical simulation serves as a unidirectional boundary condition for the fluid simulation. After a complete heart cycle of fluid simulation, a spatially resolved pressure factor (PF) is extracted and returned to the next iteration of the solid mechanical simulation, closing the loop of the iterative coupling procedure. All simulations were performed on an individualized whole heart geometry. The effect of the sequential coupling was assessed by global measures such as the change in deformation and—as an example of diagnostically relevant information—the particle residence time. The mechanical displacement was up to 2 mm after the first iteration. In the second iteration, the deviation was in the sub-millimeter range, implying that already one iteration of the proposed cycle-to-cycle coupling is sufficient to converge to a coupled limit cycle.Conclusion: Cycle-to-cycle coupling between cardiac mechanics and fluid dynamics can be a promising approach to account for fluid-structure interaction with low computational effort. In an individualized healthy whole-heart model, one iteration sufficed to obtain converged and physiologically plausible results.

Perfusion ◽  
2021 ◽  
pp. 026765912199854
Author(s):  
Mohammad Javad Ghasemi Pour ◽  
Kamran Hassani ◽  
Morteza Khayat ◽  
Shahram Etemadi Haghighi

Background and objectives: Fluid structure interaction (FSI) is defined as interaction of the structures with contacting fluids. The aortic valve experiences the interaction with blood flow in systolic phase. In this study, we have tried to predict the hemodynamics of blood flow through a normal and stenotic aortic valve in two relaxation and exercise conditions using a three-dimensional FSI method. Methods: The aorta valve was modeled as a three-dimensional geometry including a normal model and two others with 25% and 50% stenosis. The geometry of the aortic valve was extracted from CT images and the models were generated by MMIMCS software and then they were implemented in ANSYS software. The pulsatile flow rate was used for all cases and the numerical simulations were conducted based on a time-dependent domain. Results: The obtained results including the velocity, pressure, and shear stress contours in different systolic time sequences were explained and discussed. The maximum blood flow velocity in relaxation phase was obtained 1.62 m/s (normal valve), 3.78 m/s (25% stenosed valve), and 4.73 m/s (50% stenosed valve). In exercise condition, the maximum velocities are 2.86, 4.32, and 5.42 m/s respectively. The maximum blood pressure in relaxation phase was calculated 111.45 mmHg (normal), 148.66 mmHg (25% stenosed), and 164.21 mmHg (50% stenosed). However, the calculated values in exercise situation were 129.57, 163.58, and 191.26 mmHg. The validation of the predicted results was also conducted using existing literature. Conclusions: We believe that such model are useful tools for biomechanical experts. The further studies should be done using experimental data and the data are implemented on the boundary conditions for better comparison of the results.


2021 ◽  
Vol 11 (2) ◽  
pp. 13-16
Author(s):  
Artur Ovsepyan ◽  
Alexander Smirnov ◽  
Sergey Dydykin ◽  
Yuriy Vasil'ev ◽  
Evgeniy Trunin ◽  
...  

The interaction of the blood flow with the aorta is a complex dynamic event described in biomechanics as the Fluid-structure interaction. In this study we’ve developed a method for creation of a personalized 3D dynamic model of the aortic bulb and arch for the prediction of its mechanical behavior using FSI-analysis. We found that the accuracy of predicting geometric aortic deformities based on FSI modeling is on average 92%.


Author(s):  
Ahmad Moghaddaszade-Kermani ◽  
Peter Oshkai ◽  
Afzal Suleman

Mitral-Septal contact has been proven to be the cause of obstruction in the left ventricle with hypertrophic cardiomyopathy (HC). This paper presents a study on the fluid mechanics of obstruction using two-way loosely coupled fluid-structure interaction (FSI) methodology. A parametric model for the geometry of the diseased left ventricular cavity, myocardium and mitral valve has been developed, using the dimensions extracted from magnetic resonance images. The three-element Windkessel model [1] was modified for HC and solved to introduce pressure boundary condition to the aortic aperture in the systolic phase. The FSI algorithm starts at the beginning of systolic phase by applying the left ventricular pressure to the internal surface of the myocardium to contract the muscle. The displacements of the myocardium and mitral leaflets were calculated using the nonlinear finite element hyperelastic model [2] and subsequently transferred to the fluid domain. The fluid mesh was moved accordingly and the Navier-Stokes equations were solved in the laminar regime with the new mesh using the finite volume method. In the next time step, the left ventricular pressure was increased to contract the muscle further and the same procedure was repeated for the fluid solution. The results show that blood flow jet applies a drag force to the mitral leaflets which in turn causes the leaflet to deform toward the septum thus creating a narrow passage and possible obstruction.