scholarly journals Active Vibration Isolation of a Diesel Generator in a Small Marine Vessel: An Experimental Study

2020 ◽  
Vol 10 (9) ◽  
pp. 3025
Author(s):  
Tiejun Yang ◽  
Lei Wu ◽  
Xinhui Li ◽  
Minggang Zhu ◽  
Michael J. Brennan ◽  
...  

An active vibration isolation system is retrofitted to a diesel generator set in a tugboat to determine the effectiveness of such a system in a realistic practical environment. The system consists of six bespoke inertial actuators chosen to make minimal modifications to the machinery arrangement, and a DSP-based controller. Six accelerometers are collocated with the actuators on the top of six isolators to act as error sensors, and six accelerometers are placed below the isolators to give a measure of the global vibration of the ships structure below the generator set. A hydrophone is also placed in the water to give an indication of the underwater noise due to the generator. The control strategy employed is six-input and six-output decentralized adaptive feedforward control with the reference signal being derived from the signal from an optical tachometer on shaft between the engine and the generator. To suppress the vibration at all the dominant forcing frequencies, an electrical circuit generated the half engine orders required from the measured reference signal. The experimental results show that the combination of the active control system and the passive isolators is effective in reducing the global vibration and the acoustic pressure at the hydrophone position.

2012 ◽  
Vol 150 ◽  
pp. 80-84
Author(s):  
Jin Guang Zhang ◽  
Nan Xiang ◽  
Zuo Chao Xiao ◽  
Guo Ping Ding

Feedforward control method to control vibration in the active vibration isolation system was discussed. By introducing the FIR filter as the feedforward link, using the mean-square deviation of system error as the performance index and utilizing the LMS algorithm to obtain the optimal parameters of controller, the design of adaptive feedforward controller was fulfilled. The simulation results showed that: for the active vibration isolation system with regularly vibration source, adopting adaptive filter method of feedforward control has notable effect. The contrast experiment with using the PID controller further verified the simulation results.


Sign in / Sign up

Export Citation Format

Share Document