isolation system
Recently Published Documents


TOTAL DOCUMENTS

2203
(FIVE YEARS 433)

H-INDEX

40
(FIVE YEARS 9)

2022 ◽  
Author(s):  
Arash Rayegani ◽  
Gholamreza Nouri

Abstract The possibility of pounding on isolated structures with surrounding moat walls is one of the concerns in the design of isolation systems, especially in pulse-type near-field earthquakes. This paper puts forward the seismic probability assessment of structures equipped with passive and smart hybrid isolation systems by considering pounding possibilities. This investigation is performed on isolated structures equipped with a high damper rubber bearing (HDRB) considering stiff moat walls around the structure. In the Hybrid isolation system, magnetorheological dampers (MR) are considered an adaptive dissipation energy device along with isolators using an optimized novel interval Type-2 fuzzy logic controller with adaptive red-zone function (IT2FS+RZF) to reduce pounding possibilities. The fragility curves of the building for various cases are determined using IDA analysis, and possible damage costs are evaluated by using exceedance probability in each damage level. This study concludes that the collapse probability of the isolated structures with restrains at the code-based distance is over the acceptable limit of ASCE 7-22. The smart additional damping system with the proposed controller reduces the possible damage cost of the building by about 64% compared to the uncontrolled system and puts the collapse probability of the structure in the acceptable range.


2022 ◽  
Author(s):  
Hideki Uchida ◽  
Tadahito Mizutani ◽  
Susumu Yasuda ◽  
Takao Nakagawa ◽  
Shinsuke Takeuchi ◽  
...  

2022 ◽  
Vol 250 ◽  
pp. 113411
Author(s):  
Ging-Long Lin ◽  
Chi-Chang Lin ◽  
Yi-Huan Li ◽  
Tzu-Ting Lin

2021 ◽  
Vol 30 (4) ◽  
Author(s):  
Kourosh Talebi Jouneghani

The purpose of base isolation is to absorb earthquake energy, prolong the life of the structure, and enable the structure to be similar to a rigid body. However, since resonance can occur due to the closeness of the period of structures to the long period and large velocity pulses of the near field earthquakes, the stability of these buildings greatly reduces, and with the large displacement above isolation level, sometimes, tendency of overturning is created in isolators leading to their destruction. The main objective of this study is to significantly reduce the lateral displacement of base isolation subjected to near field earthquakes. In this research, seismic response calculation has been carried out for five steel moment frame structure with the 3, 5, 8, 11, and 14 stories in two states of with and without stiff core structure and energy dissipaters. The analyses has been done under fourteen scaled records of seven near-source and seven far-source earthquakes. It has been shown that the lateral displacement of base isolation system can be reduced by 87% for low-rise buildings, and 77% for high-rise buildings.


2021 ◽  
Vol 5 (4) ◽  
pp. 217-226
Author(s):  
Yu. A. Zhukov ◽  
E. B. Korotkov ◽  
S. A. Matveev ◽  
N. S. Slobodzyan ◽  
O. V. Shirobokov

The work is devoted to the protection of a spacecraft from the influence of unacceptable internal vibration sources. The urgency of reducing the vibration activity on board the spacecraft to improve the accuracy of the target equipment is indicated. A particular problem of vibration protection of the spacecraft platform from a vibration source – an electric pump unit of a liquid thermal control system – is being solved. The basic requirements for electric pump unit vibration protection have been determined. Possible ways to reduce the level of vibration excited by the electric pump unit on the surface of the spacecraft fixation are considered. Particular attention is paid to such vibration protection methods as damping and vibration isolation, implemented by installing special vibration protection devices between the source (electric pump unit) and the object (spacecraft) – vibration isolators and vibration dampers. The principles of operation of vibration dampers and vibration isolators, the most common materials for vibration dampers are described. Examples of constructive solutions for linear single-axial vibration isolators are considered, recommendations for the use of promising products are developed. Particularemphasis is placed on the use of metal rubber as a material for vibration isolators. With regard to a specific design of electric pump unit, a diagram of the spatial structure of vibration isolation is proposed. Formulas for calculation are given in detail, a mathematical model of the vibration isolation system is developed. The procedure for calculating the parameters of the system has been formed. Based on the model, the maximum possible level of vibration suppression in the mid-frequency region was determined. Minimum required number of operable pixels was identified for monitoring the water surface with sufficient accuracy and reliability.


2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Mhia Md Zaglul Shahadat ◽  
Takeshi Mizuno ◽  
Masaya Takasaki ◽  
Fazlur Rashid ◽  
Yuji Ishino

This paper presents the isolation of vibration through the acceleration feedback of the Kalman filter. In this paper, vibration isolation was analyzed both analytically and experimentally through the estimation of the Kalman filter (KF). A negative stiffness mechanism was used to reduce the level of vibration for the developed dynamic system. The technique of negative stiffness can provide stiffness of infinite level to low stiffness as well as disturbance generated by the ground vibration directly. The performance of an isolation system through a mechanism of negative stiffness was improved by the addition of acceleration feedback. Acceleration was measured using a microelectromechanical (MEMS) type accelerometer instead of traditional servo type accelerometers due to lower cost. However, the output of a microelectromechanical (MEMS) type accelerometer is usually noisy. To avoid this difficulty, an acceleration that was estimated by a Kalman filter was considered in the acceleration feedback instead of directly measured acceleration. The dynamic behaviors of the system were compared for both the Kalman-filtered acceleration and the directly measured acceleration feedback. It is observed that the former has a significant effect on the improvement of the characteristics of the vibration isolation systems than later.


Sign in / Sign up

Export Citation Format

Share Document