scholarly journals The Effect of Shank-Space on the Thermal Performance of Shallow Vertical U-Tube Ground Heat Exchangers

Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 602 ◽  
Author(s):  
Christopher Vella ◽  
Simon Paul Borg ◽  
Daniel Micallef

One parameter that may affect the performance of a ground source heat pump is the shank-space, the center-to-center distance between the two branches of a vertical U-tube used in a ground heat exchanger. A 3D steady-state computational fluid dynamics (CFD) model of a U-tube ground heat exchanger was used to investigate the influence of varying shank-space on the thermal performance of two isolated vertical shallow U-tubes, one 20 m deep and the other 40 m deep, given that most existing research focuses on systems making use of deeper boreholes. The models adopt an innovative approach, whereby the U-junction at the bottom of the U-tube is eliminated, thus facilitating the computational process. The results obtained show that, although the temperature drop across the U-tube varies for different shank-spaces and is lowest and highest for the closest and the widest shank-spaces, respectively, this temperature drop is not linear with increases in shank-space, and the thermal performance improvement drastically diminishes with increasing shank-space. This indicates that, for shallow U-tubes, the temperature drop is more dependent on the length of the pipework.

Author(s):  
Hakan Demir ◽  
Ahmet Koyun ◽  
S¸. O¨zgu¨r Atayılmaz

The most important part of a ground source heat pump (GSHP) is the ground heat exchanger (GHE) that consists of pipes buried in the soil and is used for transferring heat between the soil and the heat exchanger of the ground source heat pump. Soil composition, thermal properties and water content affect the length of ground heat exchanger. Another parameter affects the size of the ground heat exchanger is the shape. There are two basic ground heat exchanger configurations: vertical U-tube and horizontal parallel pipe. There are plenty of works on ground source heat pumps and ground heat exchangers in the literature. Most of the works on ground heat exchangers are based on the heat transfer in the soil and temperature distribution around the coil. Some of the works for thermo-economic optimization of thermal systems are based on thermodynamic cycles. This study covers comparative thermo-economical analysis of horizontal parallel pipe and vertical u-tube ground heat exchangers. An objective function has been defined based on heating capacity, investment and energy consumption costs of ground heat exchanger. Investment and energy consumption costs were taken into account as total cost in the objective function. The effects of the soil thermal conductivity, number of pipes, thermal capacity of ground heat exchanger, pipe diameter and the burial depth on the objective function were examined. The main disadvantage of U-tube ground heat exchanger is higher borehole cost that makes installation cost higher than parallel pipe ground heat exchanger. To make reference functions equal for both type of ground heat exchangers, the borehole cost must be under 20 $/m (now 55 $/m) for a given heating or cooling capacity. The performance of ground heat exchangers depends on the soil characteristics especially the soil thermal conductivity.


2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2014 ◽  
Vol 945-949 ◽  
pp. 2820-2824 ◽  
Author(s):  
Li Bai ◽  
Peng Xuan Wang

For the case of ground-source heat pump in severe cold regions in winter, the heat transfer situation of the ground and ground heat exchanger was dynamically simulated according to the statistics of a project in Changchun to analysis the change of the ground heat, which provided references for the initial design and operation and management of the ground-coupled heat pump in severe cold regions.


Author(s):  
Jalaluddin ◽  
Akio Miyara ◽  
Rustan Tarakka ◽  
Andi Amijoyo Mochtar ◽  
IR Muhammad Anis

Sign in / Sign up

Export Citation Format

Share Document