scholarly journals A Cascade Proportional Integral Derivative Control for a Plate-Heat-Exchanger-Based Solar Absorption Cooling System

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4058
Author(s):  
Yeudiel Garcíadealva ◽  
Roberto Best ◽  
Víctor Hugo Gómez ◽  
Alejandro Vargas ◽  
Wilfrido Rivera ◽  
...  

Automatic proportional integral derivative control techniques are applied in a single-stage solar absorption cooling system, showing 3.8 kW (~1 ton) cooling capacity, with a coefficient of performance of 0.6 and −4.1 °C evaporator cooling temperature. It is built with plate heat exchangers as main components, using ammonia–water as the working mixture fluid and solar collectors as the main source of hot water. Control tuning was verified with a dynamical simulation model for a solution regarding mass flow stability and temperature control in the solar absorption cooling system. The controller improved steady thermodynamic state and time response. According to experimental cooling temperatures, the system could work in ranges of refrigeration or air-conditioning end-uses, whose operation makes this control technique an attractive option to be implemented in the solar absorption cooling system.


2006 ◽  
Vol 17 (3) ◽  
pp. 65-70 ◽  
Author(s):  
V Mittal ◽  
K S Kasana ◽  
N S Thakur

This paper presents modelling and simulation of a solar absorption cooling system. In this paper, the modelling of a solar-powered, single stage, absorption cooling system, using a flat plate collector and water–lithium bromide solution, is done. A computer program has been developed for the absorption system to simulate various cycle configurations with the help of various weather data for the village Bahal, District Bhiwani, Haryana, India. The effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling component are studied. The hot water inlet temperature is found to affect the surface area of some of the system components. Moreover the effect of the reference temperature which is the minimum allowable hot water inlet temperature on the fraction of total load met by non-purchased energy (FNP) and coefficient of performance (COP) is studied and it is found that high reference temperature increases the system COP and decreases the surface area of system components but lower reference temperature gives better results for FNP than high reference temperatures.



2020 ◽  
Vol 112 ◽  
pp. 1-13 ◽  
Author(s):  
J.A. Aguilar-Jiménez ◽  
N. Velázquez-Limón ◽  
R. López-Zavala ◽  
L.A. González-Uribe ◽  
S. Islas ◽  
...  




2010 ◽  
Vol 42 (2) ◽  
pp. 265-272 ◽  
Author(s):  
T. Tsoutsos ◽  
E. Aloumpi ◽  
Z. Gkouskos ◽  
M. Karagiorgas






2020 ◽  
Vol 20 (1) ◽  
pp. 23-29
Author(s):  
Nabeel A. Ghyadh ◽  
Salman H. Hammadi ◽  
Haroun A. K. Shahad