scholarly journals Combined Operation Analysis of a Saturated Iron-Core Superconducting Fault Current Limiter and Circuit Breaker for an HVDC System Protection

Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7993
Author(s):  
Jae-In Lee ◽  
Van Quan Dao ◽  
Minh-Chau Dinh ◽  
Seok-ju Lee ◽  
Chang Soon Kim ◽  
...  

Recently, in order to overcome the difficulties of interrupting fault currents in multi-terminal direct current systems (MTDC), studies combining a saturated iron-core type superconducting current limiter (SFCL) and a direct current circuit breaker (DCCB) have been conducted. However, the effect of inductance change of the SI-SFCL on the interrupting time of the DCCB during fault has not been studied yet. In this paper, the interrupting time delay caused by the dynamic behavior of the inductance change during the fault current blocking process of the SI-SFCL combined with a DCCB was analyzed through experiments and a new fault detection method considering this phenomenon was proposed. After designing and manufacturing the laboratory-scale SI-SFCL and DCCB, a fault current interrupting test was performed and the inductance change pattern of the SI-SFCL was analyzed. Based on the analysis results, a new fault detection technique was proposed to alleviate the interruption time delay that occurs when applying the combined protection system to a MTDC, and its effectiveness was verified through a simulation. These results will be useful for planning protection coordination strategies when introducing a SI-SFCL in combination with a DCCB in actual MTDC systems.

Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1204
Author(s):  
Gul Ahmad Ludin ◽  
Mohammad Amin Amin ◽  
Hidehito Matayoshi ◽  
Shriram S. Rangarajan ◽  
Ashraf M. Hemeida ◽  
...  

This paper proposes a new and surge-less solid-state direct current (DC) circuit breaker in a high-voltage direct current (HVDC) transmission system to clear the short-circuit fault. The main purpose is the fast interruption and surge-voltage and over-current suppression capability analysis of the breaker during the fault. The breaker is equipped with series insulated-gate bipolar transistor (IGBT) switches to mitigate the stress of high voltage on the switches. Instead of conventional metal oxide varistor (MOV), the resistance–capacitance freewheeling diodes branch is used to bypass the high fault current and repress the over-voltage across the circuit breaker. The topology and different operation modes of the proposed breaker are discussed. In addition, to verify the effectiveness of the proposed circuit breaker, it is compared with two other types of surge-less solid-state DC circuit breakers in terms of surge-voltage and over-current suppression. For this purpose, MATLAB Simulink simulation software is used. The system is designed for the transmission of 20 MW power over a 120 km distance where the voltage of the transmission line is 220 kV. The results show that the fault current is interrupted in a very short time and the surge-voltage and over-current across the proposed breaker are considerably reduced compared to other topologies.


Sign in / Sign up

Export Citation Format

Share Document