scholarly journals Evaluation of Respiratory Resistance as a Predictor for Oral Appliance Treatment Response in Obstructive Sleep Apnea: A Pilot Study

2021 ◽  
Vol 10 (6) ◽  
pp. 1255
Author(s):  
Hiroyuki Ishiyama ◽  
Masayuki Hideshima ◽  
Shusuke Inukai ◽  
Meiyo Tamaoka ◽  
Akira Nishiyama ◽  
...  

The aim of this study was to determine the utility of respiratory resistance as a predictor of oral appliance (OA) response in obstructive sleep apnea (OSA). Twenty-seven patients with OSA (mean respiratory event index (REI): 17.5 ± 6.5 events/h) were recruited. At baseline, the respiratory resistance (R20) was measured by impulse oscillometry (IOS) with a fitted nasal mask in the supine position, and cephalometric radiographs were obtained to analyze the pharyngeal airway space (SPAS: superior posterior airway space, MAS: middle airway space, IAS: inferior airway space). The R20 and radiographs after the OA treatment were evaluated, and the changes from the baseline were analyzed. A sleep test with OA was carried out using a portable device. The subjects were divided into Responders and Non-responders based on an REI improvement ≥ 50% from the baseline, or REI < 5 after treatment, and the R20 reduction rate between the two groups were compared. The subjects comprised 20 responders and 7 non-responders. The R20 reduction rate with OA in responders was significantly greater than it was in non-responders (14.4 ± 7.9 % versus 2.4 ± 9.8 %, p < 0.05). In responders, SPAS, MAS, and IAS were significantly widened and R20 was significantly decreased with OA (p < 0.05). There was no significant difference in non-responders (p > 0.05). A logistic multiple regression analysis showed that the R20 reduction rate was predictive for OA treatment responses (2% incremental odds ratio (OR), 24.5; 95% CI, 21.5–28.0; p = 0.018). This pilot study confirmed that respiratory resistance may have significant clinical utility in predicting OA treatment responses.

2021 ◽  
Vol 16 (1) ◽  
pp. 404-409
Author(s):  
Souichi Yanamoto ◽  
Saori Harata ◽  
Taro Miyoshi ◽  
Norio Nakamura ◽  
Yuki Sakamoto ◽  
...  

2021 ◽  
Vol 3 (3) ◽  
pp. 01-07
Author(s):  
Guillaume Buiret ◽  
Frederic Chidiac

Objective: Oral appliances are one of the treatments of obstructive sleep apnea hypopnea syndrome. The main objective of the study was to determine the efficacy of the Somnodent® oral appliance on Apnea-Hypopnea Index. The secondary objective was to measure the efficacy on other oxymetric parameters and to determine its tolerance and dropout rate. Methods: Efficacy results of the oral appliances based on the apnea hypopnea index, the oxygen desaturation index and the lower oxygen saturation reduction, appliance complications and dropout rates were retrospectively collected from 25 patients with a moderate to severe obstructive sleep apnea hypopnea syndrome treated by a Somnodent® oral appliance. The procedure was entirely performed by otolaryngologists. Results: The AHI with OA was more significantly reduced in patients with a higher initial apnea hypopnea index and a higher initial body mass index but reduction was not related to age and not proportional to degree of mandibular advancement. The 50%-AHI reduction rate after OA was 55.6%, the AHI ≤5/h rate after OA was 22.2%. The OA significantly reduced the mean apnea-hypopnea index (-14.3/h, p<10-5). No patient had his AHI increased with oral appliance. One patient stopped using OA mainly because of nausea. Conclusions: Somnodent® is an effective and well-tolerated treatment for moderate to severe obstructive sleep apnea hypopnea syndrome.


2010 ◽  
Vol 15 (2) ◽  
pp. 203-208 ◽  
Author(s):  
Ali A. El-Solh ◽  
Binusha Moitheennazima ◽  
Morohunfolu E. Akinnusi ◽  
Paul M. Churder ◽  
Anthony M. Lafornara

2014 ◽  
Vol 155 (18) ◽  
pp. 703-707 ◽  
Author(s):  
Pálma Benedek ◽  
Gabriella Kiss ◽  
Eszter Csábi ◽  
Gábor Katona

Introduction: Treatment of pediatric obstructive sleep apnea syndrome is surgical. The incidence of postoperative respiratory complications in this population is 5–25%. Aim: The aim of the authors was to present the preoperative evaluation and monitoring procedure elaborated in Heim Pál Children Hospital, Budapest. Method: 142 patients were involved in the study. Patient history was obtained and physical examination was performed in all cases. Thereafter, polysomnography was carried out, the severity of the obstructive sleep apnea syndrome was determined, and the patients underwent tonsilloadenotomy. Results: 45 patients with mild, 50 patients with moderate and 47 patients with severe obstructive sleep apnea syndrome were diagnosed. There was no complication in patients with mild disease, while complications were observed in 6 patients in the moderate group and 24 patients in the severe group (desaturation, apnea, stridor, stop breathing) (p<0.000). In patients with severe obstructive sleep apnea syndrome, no significant difference was noted in preoperative apnoea-hypapnea index (p = 0.23) and in nadir oxygen saturation values (p = 0.73) between patients with and without complication. Conclusions: Patients with severe obstructive sleep apnea syndrome should be treated in hospital where pediatric intensive care unit is available. Orv. Hetil., 2014, 155(18), 703–707.


ORL ◽  
2021 ◽  
pp. 1-8
Author(s):  
Lifeng Li ◽  
Demin Han ◽  
Hongrui Zang ◽  
Nyall R. London

<b><i>Objective:</i></b> The purpose of this study was to evaluate the effects of nasal surgery on airflow characteristics in patients with obstructive sleep apnea (OSA) by comparing the alterations of airflow characteristics within the nasal and palatopharyngeal cavities. <b><i>Methods:</i></b> Thirty patients with OSA and nasal obstruction who underwent nasal surgery were enrolled. A pre- and postoperative 3-dimensional model was constructed, and alterations of airflow characteristics were assessed using the method of computational fluid dynamics. The other subjective and objective clinical indices were also assessed. <b><i>Results:</i></b> By comparison with the preoperative value, all postoperative subjective symptoms statistically improved (<i>p</i> &#x3c; 0.05), while the Apnea-Hypopnea Index (AHI) changed little (<i>p</i> = 0.492); the postoperative airflow velocity and pressure in both nasal and palatopharyngeal cavities, nasal and palatopharyngeal pressure differences, and total upper airway resistance statistically decreased (all <i>p</i> &#x3c; 0.01). A significant difference was derived for correlation between the alteration of simulation metrics with subjective improvements (<i>p</i> &#x3c; 0.05), except with the AHI (<i>p</i> &#x3e; 0.05). <b><i>Conclusion:</i></b> Nasal surgery can decrease the total resistance of the upper airway and increase the nasal airflow volume and subjective sleep quality in patients with OSA and nasal obstruction. The altered airflow characteristics might contribute to the postoperative reduction of pharyngeal collapse in a subset of OSA patients.


OTO Open ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 2473974X2198959
Author(s):  
Ahmed Yassin Bahgat

Objective Plasma is formed by creating a high-density energy field within an electrically conductive fluid such as saline. Sometimes ablated bits of tissue get stuck between the electrodes of the wand, obstructing the suction channel. The purpose of this study is to investigate the effect of cooling the irrigating saline during ablation of the hypertrophied tongue base in patients with obstructive sleep apnea. Study Design Prospective randomized controlled trial. Setting An otorhinolaryngology department in Main University hospitals. Methods Sixty adult patients with obstructive sleep apnea and tongue base hypertrophy underwent tongue base ablation surgery. Patients were randomly divided into 2 groups of 30 patients each: cooled saline and room temperature saline. The Coblation wand used was the EVac 70 Xtra HP (Smith & Nephew). Results In this study, a significant difference in operative time (mean ± SD) was seen between groups: 21.2 ± 5.5 minutes in the cold group and 47 ± 9.5 minutes in the control group ( P = .001). The wands in the cold group did not obstruct, while all the wands in the control group were obstructed by tissue clogs with variable degrees, hence wasting more time to clean the wands’ tips. Conclusion Cooling the irrigating saline overcame the problem of wand clogs, and the wand tip did not occlude at all during the procedures, thus saving time lost in wand cleaning and demonstrating a faster and safer surgical procedure. Further studies are needed to identify the hemostatic effect of the cooled saline over the regular one.


Sign in / Sign up

Export Citation Format

Share Document