scholarly journals Effectiveness of S-O Clip-Assisted Colorectal Endoscopic Submucosal Dissection

2021 ◽  
Vol 11 (1) ◽  
pp. 141
Author(s):  
Haruka Fujinami ◽  
Akira Teramoto ◽  
Saeko Takahashi ◽  
Takayuki Ando ◽  
Shinya Kajiura ◽  
...  

This study aimed to assess the utility of the S-O clip during colorectal endoscopic submucosal dissection (ESD). We conducted a retrospective study on 185 patients who underwent colorectal ESD from January 2015 to January 2020. The patients were divided into two groups: before and after the introduction of the S-O clip. Forty-two patients underwent conventional ESD (CO group) and 29 patients underwent ESD using the S-O clip (SO group). We compared the surgery duration, dissection speed, en bloc resection rate, and complication rate between both groups. Compared with the CO group, the SO group had a significantly shorter surgery duration (70.7 ± 37.9 min vs. 51.2 ± 18.6 min; p = 0.017), a significantly higher dissection speed (15.1 ± 9.0 min vs. 26.3 ± 13.8 min; p < 0.001), a significantly higher en bloc resection rate (80.9% vs. 98.8%; p ≤ 0.001), and a significantly lower perforation rate (4.3% vs. 1.3%). In the right colon, the surgery duration was significantly shorter and the dissection speed was significantly higher in the SO group than in the CO group. Moreover, the rate of en bloc resection improved significantly in the right colon. S-O clip-assisted ESD reduces the procedure time and improves the treatment effects, especially in the right colon.

2018 ◽  
Vol 06 (08) ◽  
pp. E975-E983 ◽  
Author(s):  
Naohisa Yoshida ◽  
Yuji Naito ◽  
Ritsu Yasuda ◽  
Takaaki Murakami ◽  
Ryohei Hirose ◽  
...  

Abstract Background and study aims Severe fibrosis poses a challenge in colorectal endoscopic submucosal dissection (ESD). Recently, the pocket-creation method (PCM) has been developed for overcoming various difficulties of ESD. A specific tapered hood is used for adequate traction in the PCM, and endoscopic operability becomes stable in the pocket. In this study, we investigated the efficacy of the PCM in ESD for cases with severe fibrosis. Patients and methods We retrospectively reviewed 1000 consecutive colorectal ESD cases (April 2006 to January 2017). Since 2016, the PCM was performed in 58 cases. The indications for ESD included (1) tumors ≥ 20 mm in size diagnosed as intramucosal cancer or high-grade dysplasia and part of T1a cancer using magnifying endoscopic examinations and (2) tumors that appeared impossible to resect with endoscopic mucosal resection because of suspected fibrosis. We identified 120 cases with severe fibrosis and compared them to cases without severe fibrosis. Additionally, the 120 severe fibrosis cases were divided into the PCM and non-PCM groups. En bloc resection, procedure time, discontinuation, and complications were analyzed between these 2 groups. Results Among all 1000 ESDs, severe fibrosis and discontinuation rates were 12.0 % (120 cases) and 1.8 % (18 cases), respectively. Regarding the comparison between cases with severe fibrosis and with no severe fibrosis, there were significant differences about en bloc resection rate (78.3 % vs. 95.7 %, P < 0.001), discontinuance rate (12.5 % vs. 0.3 %, P < 0.001), and perforation rate (8.3 % vs. 2.6 %, P = 0.001). Among the 120 cases with severe fibrosis, 21 and 99 cases were in the PCM and non-PCM groups, respectively. The PCM group had a higher en bloc resection rate (95.2 vs. 74.7, P =  0.03), a shorter mean procedure time (min) (79.6 ± 26.5 vs. 118.8 ± 71.0, P = 0.001), and no cases of discontinuation. An analysis of the interobserver agreement for the diagnosis of severe fibrosis among the 3 endoscopists showed kappa values of > 0.6. Conclusions In cases with severe fibrosis, the PCM with ESD improved en bloc resection rates and shortened the procedure time compared to the conventional non-PCM method. Additionally, the PCM reduced the discontinuation rate.


2021 ◽  
Vol 09 (05) ◽  
pp. E653-E658
Author(s):  
Tatsuma Nomura ◽  
Yoshikazu Hayashi ◽  
Takaaki Morikawa ◽  
Masahiro Okada ◽  
Hisashi Fukuda ◽  
...  

Abstract Background and study aims The pocket-creation method (PCM) facilitates dissection of the central part of a tumor. We previously developed the PCM with clip traction (PCM-CT) to facilitate opening the mucosal pocket, which otherwise could become cumbersome. In the present study, we aimed to examine the feasibility of PCM-CT for colorectal endoscopic submucosal dissection (ESD). Patients and methods PCM-CT was performed on 30 patients with early colorectal tumors from October 2019 to April 2020. PCM-CT allows efficient opening of the mucosal pocket by using the PCM to dissect the center of the lesion and then apply traction with a single clip after making a circumferential mucosal incision. Results The median specimen major axis length, ESD time, ESD speed, and en bloc resection rate were 48 mm, 84 minutes, 20 mm2/min, and 100 % (30/30), respectively. The success rates for the traction clip and median single-clip-traction time were 100 % (30/30) and 1.5 minutes, respectively. Conclusions Colorectal ESD using PCM-CT is a simple and promising method.


2021 ◽  
Vol 10 (11) ◽  
pp. 2511
Author(s):  
Yoshitsugu Misumi ◽  
Kouichi Nonaka

Endoscopic submucosal dissection (ESD) is considered superior to endoscopic mucosal resection as an endoscopic resection because of its higher en bloc resection rate, but it is more difficult to perform. As ESD techniques have become more common, and the range of treatment by ESD has expanded, the number of possible complications has also increased, and endoscopists need to manage them. In this report, we will review the management of critical complications, such as hemorrhage, perforation, and stenosis, and we will also discuss educational methods for acquiring and improving ESD skills.


2019 ◽  
Vol 07 (04) ◽  
pp. E421-E430 ◽  
Author(s):  
Uayporn Kaosombatwattana ◽  
Takeshi Yamamura ◽  
Julajak Limsrivilai ◽  
Masanao Nakamura ◽  
Somchai Leelakusolvong ◽  
...  

Abstract Background and study aims Endoscopic submucosal dissection (ESD) enables en bloc removal of colorectal neoplasms regardless of size. Submucosal fibrosis is a significant factor for technical difficulty and poor outcomes. We assessed the predictive factors for severe submucosal fibrosis and the ESD outcomes. Patients and methods Patients undergoing ESD from January 2006 to September 2017 were retrospectively reviewed. The degree of submucosal fibrosis was classified into three types: no fibrosis (F0), mild fibrosis (F1), and severe fibrosis (F2). F0 and F1 cases were grouped as non-severe fibrosis for comparison with the severe fibrosis group. Predictors of severe submucosal fibrosis and ESD outcomes were evaluated. Results ESD was performed in 524 lesions (60 % male; mean age, 67.8 years). Eighty lesions with severe fibrosis (15.3 %) were observed. The overall en bloc resection rate and curative resection rate were 94.3 % and 77.7 %, respectively. Rates of en bloc resection (91.2 % vs. 94.8 %, P = 0.2) and perforation (7.5 % vs. 5.6 %, P = 0.45) were no different between severe fibrosis and non-severe fibrosis groups. However, incidences of non-curative resection and low resection speed were significantly higher in the severe fibrosis group. Among protruding lesions, tumor height and volume were significantly greater in the severe counterparts. A diameter ≥ 40 mm, endoscopic finding of the tumor beyond fold, and fold convergence were independent risk factors for severe fibrosis. Conclusions Severe submucosal fibrosis is a significant risk factor for non-curative resection and a long procedural time. Tumor size and morphology might help to predict the severity of fibrosis.


2012 ◽  
Vol 153 (21) ◽  
pp. 824-833
Author(s):  
Gábor Balogh jr. ◽  
Zsolt Dubravcsik ◽  
Attila Szepes ◽  
László Madácsy

Endoscopic submucosal dissection is a promising new endoscopic technique for en block resection of early, superficial, flat, and laterally spreading gastrointestinal neoplasms. The primary aims of this prospective study were to summarize the first Hungarian experience with endoscopic submucosal dissection, and to compare the experimental in vivo procedures in pigs with the human application of this technique in two academic centers. Methods: The ex vivo Erlangen pig model was used until initial competence was achieved. Thereafter 15 endoscopic submucosal dissection procedures were performed in up to 5 sessions in living pigs under general anesthesia. After submucosal injection with saline Fujinone ball tip, a Flush knife was used with a transparent hood for circumferential incision and submucosal dissection. The following variables were analyzed: specimen size, complete and en bloc resection rate, total duration of the procedure, and complications. Furthermore, between 2009 and 2012, 14 endoscopic submucosal dissections were carried out in humans; 1 duodenal, 3 gastric and 10 colorectal interventions were performed due to large laterally spreading intramucosal neoplasms. The specimen size, en bloc resection rate, total duration of the procedure and complications were next analyzed. Results: 87% complete resection rate, 29.4±19.5 cm2 specimen size and 136.2±26.8 min of procedure duration were achieved in the live pig models. Nontransmural damages of the muscular layer occurred in 3/15 (20%) cases which were successfully closed with hemoclips, except in one pig that died due to fatal esophageal perforation. All bleedings were easily managed with hot biopsy forceps coagulation and hemoclips without hemodynamic instability. In humans, endoscopic submucosal dissection was accomplished with an 11/14 (79%) en block resection rate, with average resected specimen size of 11.56±4.9 cm2 and with 157±55 min of operating time. Two cases of bleeding and 2 cases of perforation occurred (14%), all of which were managed endoscopically. After 1.5 year of average follow up, local recurrence occurred in one case only. In addition, due to the 3 incomplete resections and unsuccessful endoscopic submucosal dissection, surgical intervention was required in 4 cases altogether. Conclusions: This study demonstrates the first Hungarian experience with endoscopic submucosal dissection. Training in live pig models could help endoscopists to overcome the learning curve and minimize the risk of complications before starting the procedure in humans. Reduction in the resection time and low risk of complications, especially bleeding, could be achieved by the application of a flush knife. Orv. Hetil., 2012, 153, 824–833.


Endoscopy ◽  
2018 ◽  
Vol 51 (02) ◽  
pp. 152-160 ◽  
Author(s):  
Enrique Pérez-Cuadrado-Robles ◽  
Christophe Snauwaert ◽  
Tom Moreels ◽  
Anne Jouret-Mourin ◽  
Pierre Deprez ◽  
...  

Abstract Background There are limited data regarding the risk factors and consequences of conversion to endoscopic mucosal resection (rescue EMR) during colorectal endoscopic submucosal dissection (ESD) in Western centers. Methods This was a retrospective analysis of a prospectively collected database, from which 225 consecutive ESDs performed between 2013 and 2017 were selected. Of the included patients, 39 (18.6 %) required rescue EMR. Pre- and per-procedure characteristics were evaluated to determine the features associated with the need for rescue EMR. Outcomes and complications were also assessed. Results 210 patients were included, with median tumor size of 40 mm (range 20 – 110) and most tumors being in a non-rectal location (66.2 %). When compared with full ESD, rescue EMR was significantly associated with lower rates of en bloc resection (43.6 % vs. 100 %) and complete resection (R0 status; 28.2 % vs. 88.9 %), and with a higher rate of recurrence (5.1 % vs. 0 %) and more need for surgery (15.4 % vs. 3.5 %). In multivariable analysis, non-lifting (adjusted odds ratio [ORa] 3.06, 95 % confidence interval [CI] 1.23 – 7.66; P = 0.02), nongranular-type laterally spreading tumor (LST-NG; ORa 2.56, 95 %CI 1.10 – 5.99; P = 0.03), and difficult retroflexion (OR 3.22, 95 %CI 1.01 – 10.28; P = 0.049) were independent risk factors associated with conversion to rescue EMR, while tumor size and location were not. Conclusions During ESD, the presence of poor lifting, LST-NG morphology, and a difficult retroflexed approach were factors associated with the need to convert to rescue EMR. Conversion to rescue EMR remains a valuable strategy.


2019 ◽  
Vol 07 (09) ◽  
pp. E1187-E1191 ◽  
Author(s):  
Taiji Yoshimoto ◽  
Hiroshi Takihara ◽  
Tomoatsu Yoshihara ◽  
Taro Inoue ◽  
Kohei Ishibashi ◽  
...  

Abstract Background and study aims Although colorectal endoscopic submucosal dissection (ESD) has enabled high en bloc resection rates regardless of tumor size, colorectal ESD is still a challenging procedure. We developed a novel device called the Nelaton Attachment, which allows endoscopists to manipulate the ESD knives using two fingers of their left hand while holding the endoscope with their right hand. We retrospectively investigated the efficacy and safety of the Nelaton Attachment for colorectal ESD. We compared efficacy and safety between Nelaton Attachment and non-Nelaton Attachment groups, and also conducted an ex vivo experiment to evaluate the effect of the Nelaton Attachment. Patients and methods We retrospectively reviewed 36 consecutive patients with 37 colorectal tumors who had undergone ESD at Kishiwada Tokushukai Hospital and Naritatomisato Tokushukai Hospital between April 2016 and September 2018. The Nelaton Attachment was used for 22 of the 37 colorectal ESDs. In the ex vivo experiment, endoscopists inserted and withdrew an ESD knife 2 cm using two fingers of their left hand with and without the Nelaton Attachment. Results Median procedure time was significantly shorter in the Nelaton Attachment group (38 min [range 6 – 195 min]) compared to the non-Nelaton Attachment group (75 min [range 17 – 198 min]; P = 0.030). Median time to complete the ex vivo experiment five times was significantly faster with the Nelaton Attachment than without the Nelaton Attachment (P = 0.001). Conclusions Use of the Nelaton Attachment for colorectal ESD is feasible and safe, and may facilitate colorectal ESD procedures.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Henrik Thorlacius ◽  
Noryia Uedo ◽  
Ervin Toth

Objectives. Endoscopic submucosal dissection (ESD) is an effective method for en bloc removal of large colorectal tumors in Japan, but this technique is not yet widely established in western countries. The purpose here was to report the experience of implementing colorectal ESD in Sweden.Methods. Twenty-nine patients with primarily nonmalignant and early colorectal neoplasms considered to be too difficult to remove en bloc with EMR underwent ESD. Five cases of invasive cancer underwent ESD due to high comorbidity excluding surgical intervention or as an unexpected finding.Results. The median age of the patients was 74 years. The median tumor size was 26 mm (range 11–89 mm). The median procedure time was 142 min (range 57–291 min). En bloc resection rate was 72% and the R0 resection rate was 69%. Two perforations occurred amounting to a perforation rate of 6.9%. Both patients with perforation could be managed conservatively. One bleeding occurred during ESD but no postoperative bleeding was observed.Conclusion. Our data confirms that ESD is an effective method for en bloc resection of large colorectal adenomas and early cancers. This study demonstrates that implementation of colorectal ESD is feasible in Sweden after proper training, careful patient selection, and standardization of the ESD procedure.


2020 ◽  
Author(s):  
Ting Fan ◽  
Qi Sun ◽  
Shouli Cao ◽  
Xiangshan Fan ◽  
Qin Huang ◽  
...  

Abstract Background: Endoscopic submucosal dissection (ESD) has been accepted as a standard treatment for early gastric cardiac cancer (EGCC). Here, we investigate the clinical outcomes of the EGCC patients who underwent ESD in different indications. Methods: From January 2011 to October 2019, we enrolled 502 EGCC lesions from 495 patients which were resected by ESD at our center. We retrospectively analyzed the short-term and long-term clinical outcomes among different indication groups. Results: The number of the patients in the absolute indication (AI), expanded indication (EI) and beyond the expanded indication (BEI) groups was 265, 137 and 93, respectively. The en bloc resection rate was 100%, 100% and 98.9% ( P =0.185). The complete resection rate was 99.3%, 98.5% and 74.5%, respectively ( P <0.001). During a median follow-up of 48.1 months, the lymph node metastasis rate was 0%, 0% and 2.3% ( P <0.001). The distant metastasis rate was 0.4%, 0% and 2.3% ( P =0.150). The five-year disease-specific survival rate in the BEI group was 96.6% ( P =0.016), compared to 99.6% in the AI group and 100% in the EI group. Conclusion: The efficacy for ESD patients in EI group was almost equal to the AI group. Patients in the BEI group showed generally favorable clinical outcomes and needed to be carefully checked after ESD. ESD may be an optional treatment for patients unsuitable for gastrectomy.


Sign in / Sign up

Export Citation Format

Share Document