scholarly journals 3D Printed Acetabular Cups for Total Hip Arthroplasty: A Review Article

Metals ◽  
2019 ◽  
Vol 9 (7) ◽  
pp. 729 ◽  
Author(s):  
Dall’Ava ◽  
Hothi ◽  
Di Laura ◽  
Henckel ◽  
Hart

Three-dimensional (3D) printed titanium orthopaedic implants have recently revolutionized the treatment of massive bone defects in the pelvis, and we are on the verge of a change from conventional to 3D printed manufacture for the mass production of millions of off-the-shelf (non-personalized) implants. The process of 3D printing has many adjustable variables, which taken together with the possible variation in designs that can be printed, has created even more possible variables in the final product that must be understood if we are to predict the performance and safety of 3D printed implants. We critically reviewed the clinical use of 3D printing in orthopaedics, focusing on cementless acetabular components used in total hip arthroplasty. We defined the clinical and engineering rationale of 3D printed acetabular cups, summarized the key variables involved in the manufacturing process that influence the properties of the final parts, together with the main limitations of this technology, and created a classification according to end-use application to help explain the controversial and topical issues. Whilst early clinical outcomes related to 3D printed cups have been promising, in-depth robust investigations are needed, partly because regulatory approval systems have not fully adapted to the change in technology. Analysis of both pristine and retrieved cups, together with long-term clinical outcomes, will help the transition to 3D printing to be managed safely.

2019 ◽  
Vol 34 (10) ◽  
pp. 2511-2518 ◽  
Author(s):  
Ivan De Martino ◽  
Vanni Strigelli ◽  
Giorgio Cacciola ◽  
Alex Gu ◽  
Mathias P. Bostrom ◽  
...  

2020 ◽  
Vol 4 (04) ◽  
pp. 155-157
Author(s):  
Michael Newman ◽  
David Hartwright

AbstractThe aim of this study was to assess a large, single-surgeon dataset of uncemented total hip arthroplasties that had been templated using software. This assessment compared preoperative templated predictions with what was implanted with regard to (1) femoral prosthesis size and (2) acetabular cup size. The operation notes for two types of uncemented total hip arthroplasty performed by a single surgeon between January 9, 2008, and March 21, 2019, were assessed. The data were refined so that only those that were fully templated on a correctly calibrated pelvic radiograph were included. This provided a total of 153 cases. The predicted software template was compared with actual implanted component sizes. With regard to the femoral stems, the templating software was exactly correct in 45.75% of cases and was accurate to within one size in 87.59% of cases. With regard to the acetabular component, the templating software was exactly correct in 52.94% of cases and was accurate to within one size (2 mm) in 86.94% of cases. Templating software offers an accurate prediction of the size of uncemented femoral and acetabular components. In addition, the benefits of templating include cognitive rehearsal, insight into potentially challenging aspects of surgery, and highlighting intraoperative issues where there is a large intraoperative deviation from what is templated. This study demonstrates the congruence and reproducibility of templating software when compared with other smaller studies performed in the literature.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Taku Ukai ◽  
Goro Ebihara ◽  
Masahiko Watanabe

Abstract Background This study aims to evaluate postoperative pain and functional and clinical outcomes of anterolateral supine (ALS) and posterolateral (PL) approaches for primary total hip arthroplasty. Materials and methods We retrospectively examined the joints of 110 patients who underwent primary total hip arthroplasty (THA). The ALS group was compared with the PL group using the pain visual analog scale (VAS) and narcotic consumption as pain outcomes. Functional outcomes included postoperative range of motion (ROM) of hip flexion, day on which patients could perform straight leg raising (SLR), day on which patients began using a walker or cane, duration of hospital stay, rate of transfer, and strength of hip muscles. Clinical outcomes included pre and postoperative Harris Hip Scores. Results No significant differences were found in the pain VAS scores or narcotic consumption between the two groups. The PL group could perform SLR earlier than the ALS group (P < 0.01). The ALS group started using a cane earlier (P < 0.01) and had a shorter hospital stay (P < 0.01) than the PL group. Degrees of active ROM of flexion at postoperative day (POD) 1 were significantly lower in the ALS group than in the PL group (P < 0.01). Regarding hip muscle strength, hip flexion was significantly weaker in the ALS group than in the PL group until 1-month POD (P < 0.01). External rotation from 2 weeks to 6 months postoperatively was significantly weaker in the PL group than in the ALS group (P < 0.01). Conclusion The ALS approach was more beneficial than the PL approach because ALS enabled better functional recovery of the strength of external rotation, improved rehabilitation, and involved a shorter hospital stay. Level of Evidence Level IV retrospective observational study.


2021 ◽  
pp. postgradmedj-2021-141135
Author(s):  
Vishal Kumar ◽  
Sandeep Patel ◽  
Vishnu Baburaj ◽  
Rajesh Kumar Rajnish ◽  
Sameer Aggarwal

BackgroundRobot-assisted total hip arthroplasty (THA) is an emerging technology that claims to position implants with very high accuracy. However, there is currently limited data in literature on whether this improved accuracy leads to better long-term clinical outcomes. This systematic review compares the outcomes of THA done with the help of robotic assistance (RA) to those done with conventional manual techniques (MTs).MethodsFour electronic databases were searched for eligible articles that directly compared robot-assisted THA to manual THA and had data on the radiological or clinical outcomes of both. Data on various outcome parameters were collected. Meta-analysis was conducted using a random-effects model with 95% CIs.ResultsA total of 17 articles were found eligible for inclusion, and 3600 cases were analysed. Mean operating time in the RA group was significantly longer than in the MT group. RA resulted in significantly more acetabular cups being placed inside Lewinnek’s and Callanan’s safe zones (p<0.001) and had significantly reduced limb length discrepancy compared with MT. There were no statistically significant differences in the two groups in terms of incidence of perioperative complications, need for revision surgery and long-term functional outcome.ConclusionRA leads to highly accurate implant placement and leads to significantly reduced limb length discrepancies. However, the authors do not recommend robot-assisted techniques for routine THAs due to lack of adequate long-term follow-up data, prolonged surgical times and no significant differences in the rate of complications and implant survivorship compared with conventional MTs.


2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


2018 ◽  
Vol 29 (2) ◽  
pp. 222-225
Author(s):  
William Stickney ◽  
Richard S Yoon ◽  
Jay N Patel ◽  
David S Klein ◽  
George J Haiduekwych ◽  
...  

Introduction: In the revision setting, intrapelvic acetabular components provide a unique set of challenges for the treating surgeon. Retrieval is complicated by complex anatomical relationships within the pelvis and historically, surgeons have used multiple approaches to safely retrieve the cup. Case presentation: We present the case of a 53-year-old female with intrapelvic migration of the acetabular components of her total hip arthroplasty. Patient was treated through a novel, single incision approach with utilisation of an anterior inferior iliac spine (AIIS) osteotomy. Results: An AIIS osteotomy allows for improved visualisation within the pelvis and safe retrieval through a single exposure without compromising the ability to perform definitive, revision reconstruction. At 1-year follow-up, the patient has had no complications related to infection or failure of the implants. Ambulation is performed with the aid of a cane in the community with mild, occasional pain.


Sign in / Sign up

Export Citation Format

Share Document