scholarly journals Generation of Benchmark Problems for Optimal Design of Water Distribution Systems

Water ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 1637 ◽  
Author(s):  
Ho Min Lee ◽  
Donghwi Jung ◽  
Ali Sadollah ◽  
Do Guen Yoo ◽  
Joong Hoon Kim

Engineering benchmark problems with specific characteristics have been used to compare the performance and reliability of metaheuristic algorithms, and water distribution system design benchmarks are also widely used. However, only a few benchmark design problems have been considered in the research community. Due to the limited set of previous benchmarks, it is challenging to identify the algorithm with the best performance and the highest reliability among a group of algorithms. Therefore, in this study, a new water distribution system design benchmark problem generation method is proposed considering problem size and complexity modifications of a reference benchmark. The water distribution system design benchmark problems are used for performance and reliability comparison among several reported metaheuristic optimization algorithms. The optimal design results are able to quantify the performance and reliability of the compared algorithms which shows each metaheuristic algorithm has its own strengths and weaknesses. Finally, using the proposed method in this study, guidelines are derived for selecting an appropriate metaheuristic algorithm for water distribution system design.

Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 567 ◽  
Author(s):  
Kegong Diao ◽  
Robert Sitzenfrei ◽  
Wolfgang Rauch

Resilient water distribution systems (WDSs) need to minimize the level of service failure in terms of magnitude and duration over its design life when subject to exceptional conditions. This requires WDS design to consider scenarios as close as possible to real conditions of the WDS to avoid any unexpected level of service failure in future operation (e.g., insufficient pressure, much higher operational cost, water quality issues, etc.). Thus, this research aims at exploring the impacts of design flow scenarios (i.e., spatial-variant demand patterns) on water distribution system design and operation. WDSs are traditionally designed by using a uniform demand pattern for the whole system. Nevertheless, in reality, the patterns are highly related to the number of consumers, service areas, and the duration of peak flows. Thus, water distribution systems are comprised of distribution blocks (communities) organized in a hierarchical structure. As each community may be significantly different from the others in scale and water use, the WDSs have spatially variable demand patterns. Hence, there might be considerable variability of real flow patterns for different parts of the system. Consequently, the system operation might not reach the expected performance determined during the design stage, since all corresponding facilities are commonly tailor-made to serve the design flow scenario instead of the real situation. To quantify the impacts, WDSs’ performances under both uniform and spatial distributed patterns are compared based on case studies. The corresponding impacts on system performances are then quantified based on three major metrics; i.e., capital cost, energy cost, and water quality. This study exemplifies that designing a WDS using spatial distributed demand patterns might result in decreased life-cycle cost (i.e., lower capital cost and nearly the same pump operating cost) and longer water ages. The outcomes of this study provide valuable information regarding design and operation of water supply infrastructures; e.g., assisting the optimal design.


Water ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1163
Author(s):  
Mengning Qiu ◽  
Avi Ostfeld

Steady-state demand-driven water distribution system (WDS) solution is the bedrock for much research conducted in the field related to WDSs. WDSs are modeled using the Darcy–Weisbach equation with the Swamee–Jain equation. However, the Swamee–Jain equation approximates the Colebrook–White equation, errors of which are within 1% for ϵ/D∈[10−6,10−2] and Re∈[5000,108]. A formulation is presented for the solution of WDSs using the Colebrook–White equation. The correctness and efficacy of the head formulation have been demonstrated by applying it to six WDSs with the number of pipes ranges from 454 to 157,044 and the number of nodes ranges from 443 to 150,630. The addition of a physically and fundamentally more accurate WDS solution method can improve the quality of the results achieved in both academic research and industrial application, such as contamination source identification, water hammer analysis, WDS network calibration, sensor placement, and least-cost design and operation of WDSs.


2004 ◽  
Vol 2 (3) ◽  
pp. 137-156 ◽  
Author(s):  
M. M. Aral ◽  
J. Guan ◽  
M. L. Maslia ◽  
J. B. Sautner ◽  
R. E. Gillig ◽  
...  

In a recently completed case-control epidemiological study, the New Jersey Department of Health and Senior Services (NJDHSS) with support from the Agency for Toxic Substances and Disease Registry (ATSDR) documented an association between prenatal exposure to a specific contaminated community water source and leukaemia in female children. An important and necessary step in the epidemiological study was the reconstruction of the historical water supply strategy of the water distribution system serving the Dover Township area, New Jersey. The sensitivity of solutions to: (1) pressure and pattern factor constraints, (2) allowable operational extremes of water levels in the storage tanks, and (3) the non-uniqueness of the water supply solution are analysed in detail. The computational results show that the proposed approach yields satisfactory results for the complete set of monthly simulations and sensitivity analyses, providing a consistent approach for identifying the historical water supply strategy of the water distribution system. Sensitivity analyses indicated that the alternative strategy obtained from the revised objective function and the variation of constraints did not yield significantly different water supply characteristics. The overall analysis demonstrates that the progressive optimality genetic algorithm (POGA) developed to solve the optimization problem is an effective and efficient algorithm for the reconstruction of water supply strategies in water distribution systems.


2013 ◽  
Vol 59 (3) ◽  
pp. 183-188 ◽  
Author(s):  
V.M. Siqueira ◽  
H.M.B. Oliveira ◽  
C. Santos ◽  
R.R.M. Paterson ◽  
N.B. Gusmão ◽  
...  

Filamentous fungi in drinking water can block water pipes, can cause organoleptic biodeterioration, and are a source of pathogens. There are increasing reports of the involvement of the organisms in biofilms. This present study describes a sampling device that can be inserted directly into pipes within water distribution systems, allowing biofilm formation in situ. Calcofluor White M2R staining and fluorescent in situ hybridization with morphological analyses using epifluorescent microscopy were used to analyse biofilms for filamentous fungi, permitting direct observation of the fungi. DAPI (4′,6-diamidino-2-phenylindole) was applied to detect bacteria. Filamentous fungi were detected in biofilms after 6 months on coupons exposed to raw water, decanted water and at the entrance of the water distribution system. Algae, yeast, and bacteria were also observed. The role of filamentous fungi requires further investigations.


2019 ◽  
Vol 22 (4) ◽  
pp. 681-690 ◽  
Author(s):  
A. Fiorini Morosini ◽  
O. Caruso ◽  
P. Veltri

Abstract The current paper reports on a case study investigating water distribution system management in emergency conditions when it is necessary to seal off a zone with isolation valves to allow repair. In these conditions, the pressure-driven analysis (PDA) is considered to be the most efficient approach for the analysis of a water distribution network (WDN), as it takes into account whether the head in a node is adequate to ensure service. The topics of this paper are innovative because, until now, previous approaches were based on the analysis of the network behaviour in normal conditions. In emergency conditions, it is possible to measure the reliable functioning of the system by defining an objective function (OF) that helps to choose the optimal number of additional valves in order to obtain adequate system control. The OF takes into account the new network topology by excluding the zone where the broken pipe is located. The results show that the solution did not improve significantly when the number of valves reached a threshold. The procedure applied to other real case studies seems to confirm the efficiency of the methodology even if further examination of other cases in different conditions is necessary.


Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 553 ◽  
Author(s):  
Young Choi ◽  
Joong Kim

This study proposes a multi-objective optimal design approach for water distribution systems, considering mechanical system redundancy under multiple pipe failure. Mechanical redundancy is applied to the system’s hydraulic ability, based on the pressure deficit between the pressure requirements under abnormal conditions. The developed design approach shows the relationships between multiple pipe failure states and system redundancy, for different numbers of pipe-failure conditions (e.g., first, second, third, …, tenth). Furthermore, to consider extreme demand modeling, the threshold of the demand quantity is investigated simultaneously with multiple pipe failure modeling. The design performance is evaluated using the mechanical redundancy deficit under extreme demand conditions. To verify the proposed design approach, an expanded version of the well-known benchmark network is used, configured as an ideal grid-shape, and the multi-objective harmony search algorithm is used as the optimal design approach, considering construction cost and system mechanical redundancy. This optimal design technique could be used to propose a standard for pipe failure, based on factors such as the number of broken pipes, during failure condition analysis for redundancy-based designs of water distribution systems.