scholarly journals Analyze The Effects of Helical Baffles Angles Variation On Shell Side Heat Transfer Coefficient And Pressure Drop of Shell And Tube Heat Exchange

2019 ◽  
Vol 2 (1) ◽  
pp. 43-52
Author(s):  
Linta Atina Rahmah ◽  
Devy Setiorini Sa’adiyah ◽  
Sulistijono Sulistijono

E-201-11 is one of the components of heat exchanger which serves to increase the temperature of distillated crude oil before it going into the furnace. The use of segmental baffles on the heat exchanger causes dead zone. The fouling phenomenon that arises from the deposition of the compound content in the service fluid in dead zone can result in leakage of the shell and tube. It affects the performance of heat exchanger and production efficiency. The use of discontinuous helical baffle on the shell side minimizes fouling. Research on the variation of helical baffle angle by using Bell-Delaware method resulted in performance value of heat transfer coefficient and pressure drop on the shell side. Fluid flow behavior on the shell side with helical baffle was analyzed by Computational Fluid Dynamics (CFD). The fluid flow velocity is a factor that affects the value of heat transfer coefficient and pressure drop. Heat exchanger with an angle of 10º have fluid flow velocity of 0,893m/s resulting in the highest heat transfer coefficient and pressure drop value compared to angles of 15º and 20º with values of 585.725W/m²K and 13642.395Pa. The heat exchanger with helical baffle at 10° helix angle presents the best performance among the others variant helical baffles

2007 ◽  
Vol 129 (10) ◽  
pp. 1425-1431 ◽  
Author(s):  
B. Peng ◽  
Q. W. Wang ◽  
C. Zhang ◽  
G. N. Xie ◽  
L. Q. Luo ◽  
...  

Two shell-and-tube heat exchangers (STHXs) using continuous helical baffles instead of segmental baffles used in conventional STHXs were proposed, designed, and tested in this study. The two proposed STHXs have the same tube bundle but different shell configurations. The flow pattern in the shell side of the heat exchanger with continuous helical baffles was forced to be rotational and helical due to the geometry of the continuous helical baffles, which results in a significant increase in heat transfer coefficient per unit pressure drop in the heat exchanger. Properly designed continuous helical baffles can reduce fouling in the shell side and prevent the flow-induced vibration as well. The performance of the proposed STHXs was studied experimentally in this work. The heat transfer coefficient and pressure drop in the new STHXs were compared with those in the STHX with segmental baffles. The results indicate that the use of continuous helical baffles results in nearly 10% increase in heat transfer coefficient compared with that of conventional segmental baffles for the same shell-side pressure drop. Based on the experimental data, the nondimensional correlations for heat transfer coefficient and pressure drop were developed for the proposed continuous helical baffle heat exchangers with different shell configurations, which might be useful for industrial applications and further study of continuous helical baffle heat exchangers. This paper also presents a simple and feasible method to fabricate continuous helical baffles used for STHXs.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.


Author(s):  
Guidong Chen ◽  
Jing Xu ◽  
Ming Zen ◽  
Qiuwang Wang

In order to improve heat transfer performance of conventional segmental baffled shell-and-tube heat exchangers (STHXs), the shell-and-tube heat exchanger with combined helical baffles (CMH-STHX) were invented. In the present study, the CMH-STHX is compared with three other STHXs which were set up with continuous helical baffles (CH-STHX), discontinuous helical baffles (DCH-STHX) and segmental baffles (SG-STHX), by Computational Fluid Dynamics method. The numerical results show that, for the same mass flow rate at the shell side, the overall pressure drop of the CMH-STHX is about 50% and 40% lower than that of SG-STHX and CH-STHX. The heat transfer coefficient of the CMH-STHX is between those of CH-STHX and DCH-STHX and it is 6.3% lower than that of SG-STHX. The heat transfer coefficient under unit pressure drop h/Δp is introduced to evaluate the comprehensive performance of STHXs. The h/Δp of the CMH-STHX is 7.5%, 6.5% and 87.4% higher on average than those of the CH-SHTX, DCH-STHX and SG-STHX. Furthermore, the total heat transfer rate of CMH-STHX is about 25% higher than that of SG-STHX for the same total pressure drop of shell side. Supported by these results, the new heat exchanger (CMH-STHX) may be used to replace the conventional shell-and-tube heat exchanger in industrial applications.


Author(s):  
Yaping Chen ◽  
Ruibing Cao ◽  
Jiafeng Wu ◽  
Cong Dong ◽  
Yanjun Sheng

A set of experiments were conducted on the circumferential overlap trisection helical baffle heat exchangers with inclined angles of 20°, 24°, 28° and 32° single-thread and inclined angle of 32° dual-thread one, and a segmental baffle heat exchanger as a contrast scheme. The cylinder case of the testing heat exchanger is a common shell, while the tube bundle core could be replaced. The shell side heat transfer coefficient ho is obtained by subtract tube-side convection thermal resistance and tube wall conduction resistance from the overall heat transfer coefficient K. The curves of shell side heat transfer coefficient ho, pressure drop Δpo, Nusselt number Nuo, and axial Euler number Euz,o are presented versus axial Reynolds number Rez,o. A comprehensive performance index Nuo/Euz,o is suggested to demonstrate the integral properties of both heat transfer and flow resistance of different schemes, and the curves of Nuo/Euz,o versus Rez,o of the different schemes are presented. The results show that the scheme with inclined angle 20° performs better than other schemes, and the scheme with inclined angle 24° ranks the second, however the segment scheme ranks the last. The curves of Nuo/Euz,o of both schemes with inclined angle 32° of single-thread and dual-thread are almost coincident, even though their heat transfer coefficient and pressure drop curves are quite different. The results indicate also that for the circumferential overlap trisection helical baffle schemes the optimal inclined angle is around 20° instead of around 40° as rated by many literatures for the quadrant helical baffle schemes.


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4138 ◽  
Author(s):  
Yue Sun ◽  
Xinting Wang ◽  
Rui Long ◽  
Fang Yuan ◽  
Kun Yang

In this work, a shell and tube heat exchanger with inclined trefoil-hole baffles (STHX-IT) is proposed, and the numerical simulation is conducted to investigate the flow and heat transfer characteristics. A shell and tube heat exchanger with segmental baffles (STHX-SG) is also studied for the performance comparison. The results show that the heat transfer coefficient and pressure drop of the STHX-IT is averagely lower by 23.89% and 44.19% than those of the STHX-SG, but the heat transfer coefficient per pressure drop is higher by 36.38% on average. Further, the parametric studies of the inclination angle θ, trefoil-hole number n, and baffle cut δ are carried out for the STHX-IT. According to the numerical results, n and δ have more notable influence on shell side performance than θ. In detail, the heat transfer coefficient and pressure drop decrease slightly with θ increasing, and the overall performance is approximately equal; both the heat transfer coefficient and pressure drop decrease with the respective rising of n and δ, but the comprehensive performance shows a growing trend. Considering the synthetic effects of structural parameters, the multi-objective structure optimization using the genetic algorithm combined with the artificial neural networks is fulfilled. As a result, the Pareto front is obtained to characterize the behaviors of the maximum heat transfer rate and minimum pressure drop. The STHX-IT with the θ = 5.38°, n = 6, and δ = 43% is decided as the optimal solution by the TOPSIS method, whose Q/Δp is 2.34 times as much as that of the original STHX-SG.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


Author(s):  
S. V. Sridhar ◽  
R. Karuppasamy ◽  
G. D. Sivakumar

Abstract In this investigation, the performance of the shell and tube heat exchanger operated with tin nanoparticles-water (SnO2-W) and silver nanoparticles-water (Ag-W) nanofluids was experimentally analyzed. SnO2-W and Ag-W nanofluids were prepared without any surface medication of nanoparticles. The effects of volume concentrations of nanoparticles on thermal conductivity, viscosity, heat transfer coefficient, fiction factor, Nusselt number, and pressure drop were analyzed. The results showed that thermal conductivity of nanofluids increased by 29% and 39% while adding 0.1 wt% of SnO2 and Ag nanoparticles, respectively, due to the unique intrinsic property of the nanoparticles. Further, the convective heat transfer coefficient was enhanced because of improvement of thermal conductivity of the two phase mixture and friction factor increased due to the increases of viscosity and density of nanofluids. Moreover, Ag nanofluid showed superior pressure drop compared to SnO2 nanofluid owing to the improvement of thermophysical properties of nanofluid.


Author(s):  
Fadi A. Ghaith ◽  
Ahmed S. Izhar

This paper aims to enhance the thermal performance of an industrial shell-and-tube heat exchanger utilized for the purpose of cooling raw natural gas by means of mixture of Sales gas. The main objective of this work is to provide an optimum and reliable thermal design of a single-shelled finned tubes heat exchanger to replace the existing two- shell and tube heat exchanger due to the space limitations in the plant. A comprehensive thermal model was developed using the effectiveness-NTU method. The shell-side and tube-side overall heat transfer coefficient were determined using Bell-Delaware method and Dittus-Boelter correlation, respectively. The obtained results showed that the required area to provide a thermal duty of 1.4 MW is about 1132 m2 with tube-side and shell-side heat transfer coefficients of 950 W/m2K and 495 W/m2K, respectively. In order to verify the obtained results generated from the mathematical model, a numerical study was carried out using HTRI software which showed a good match in terms of the heat transfer area and the tube-side heat transfer coefficient.


Author(s):  
Shui Ji ◽  
Wenjing Du ◽  
Lin Cheng

Since its appearance in the 80’s of the 20th century, the heat exchanger with helical baffles (HEHBs) has attracted lots of attention. Benefiting from its relatively simple manufacture procedure and low cost, the heat exchanger with overlapped helical baffles receives much concern. However, there are few reports on the influence of the specific overlap size of helical baffles on the shell-side heat transfer performance and fluid friction property. In this paper, numerical investigation on this open issue is carried out by means of numerical method. The emphasis is laid on the relationship between the overlap size of helical baffles and the shell-side performance. Baffles with the shape of a quarter-ellipse are simulated and the heat-transfer oil is selected as the working fluid. Results show that in the condition of same helix angles and same flow rates, 10% increase of the specific overlap size brings an increase of 23–42% on the pressure drop and an increase of 2–8% on the convection heat transfer coefficient; hence the corresponding heat transfer coefficient pre unit pressure drop is decreased by 11–22%. Compared with the continuously overlap configuration, the axially staggered overlap helical baffles can improve the comprehensive performance of HEHBs on the condition of an identical helical pitch, and hence it is favorable for the situation with strict constrain on pressure drop.