scholarly journals An Efficient Two step Algorithm for Despeckling the Ultrasound Image

The speckle noise presence in ultrasound images is a critical concern in medical image processing. It degrades the important features captured in an image and decreases the physician’s capacity to understand the image accurately. In recent years, numerous techniques have been proposed to de-noise the ultrasound images. In this paper, a new speckle noise removal algorithm has been proposed for medical ultrasound images. Based on the concepts of fuzzy logic and Coefficient of variation, the proposed algorithm first classifies the image area into three different regions such as homogeneous, edge and detail region. Next, average filter, median filter and an adaptive mean filter are employed to partition the unwanted noise from the pixels of different regions. Filter selection depends on the features of a region. The proposed algorithm develops image quality by removing maximum unwanted noise while protecting the important image details

2020 ◽  
Vol 1 (2) ◽  
pp. 71-77
Author(s):  
Rasheed Ihsan ◽  
Saman Almufti ◽  
Ridwan Marqas

Ultrasound imaging helps the doctor to view the tissues and organs in the body's abdominal area with no ionization risks compared to other internal organ examination methods dependent on radiation. It offers highly precise renal imaging of suspected acute kidney diseases. This paper proposes temporary filtering methods to improve ultrasound images from ultrasonic kidney video. The proposed filters focus on the detection and diagnosis of kidney disease by processing consecutive images of the acquired kidney video. Extending the spatial median image filters to temporal dimensions after the picture frames are manually clipped and aligned in MATLAB by image processing Toolbox to suppress speckle noise, and enhance a doctor's diagnostic information quality.


Author(s):  
A. G. Rudnitskii ◽  
M. A. Rudnytska ◽  
L. V. Tkachenko ◽  
E. D. Pechuk

Denoising is an important step in the early stage of signal preprocessing in optoacoustic applications. The efficiency of such modern noise removal methods as wavelet or curvlet filtering depends significantly on the numerical combinations and forms of wavelet transform parameters, and the multidimensional extension of such filters is rather non-trivial. These issues are serious obstacle for using of these highly effective filters in the tasks of optoacoustic reconstruction, especially in real laboratorial or medical practice. The objective of our study was to find the optimal filter, convenient for use in laboratorian and medical practice, when the types of noise are a priori unknown, and the filter settings should not take much time. In the offered work spatial filters which have only one parameter of adjustment - the size of a window are considered. Three-dimensional extensions of such well-established denoising techniques, as mean filter, median filter, their adaptive variants (Wiener spatial filter and modified median filter), as well as iterative truncated arithmetic mean filter were analyzed. The proposed filters were tested on a test set that contains versions of Shepp-Logan's three-dimensional phantom with mixtures of Gaussian and alpha-stable noise, as well as speckle noise. The identification of the best filter for simultaneous suppression of these types of interference was carried out using the theory of fuzzy sets. In our tests, a modified median filter and an iterative truncated arithmetic mean filter were rated as the best choice when the goal is to minimize aberrations when noise is not known a priory.


2020 ◽  
Vol 8 (5) ◽  
pp. 1851-1854

In medical images, medical images are corrupted by different types of noise. It is important to get a precise picture and accurately observe the correspondence. Removing noise from medical images has become a very difficult problem in the field of the medical image. The most well-known noise reduction method, which is usually based on the local statistics of medical images, is efficient because of the noise reduction of medical images. In paper, an efficient and simple method for noise reduction from medical images is presented. The paper proposes a filtering system to combine both the Median filter and Gaussian filter to remove the Speckle noise form Medical and Ultrasound images. The image quality is measured through statistical quantities: Peak signal to noise ratio (PSNR). Experimental results show that the proposed system removes Speckle noise from medical images.


Author(s):  
Prerna Singh ◽  
Ramakrishnan Mukundan ◽  
Rex De Ryke

Speckle noise reduction is an important area of research in the field of ultrasound image processing. Several algorithms for speckle noise characterization and analysis have been recently proposed in the area. Synthetic ultrasound images can play a key role in noise evaluation methods as they can be used to generate a variety of speckle noise models under different interpolation and sampling schemes, and can also provide valuable ground truth data for estimating the accuracy of the chosen methods. However, not much work has been done in the area of modelling synthetic ultrasound images, and in simulating speckle noise generation to get images that are as close as possible to real ultrasound images. An important aspect of simulated synthetic ultrasound images is the requirement for extensive quality assessment for ensuring that they have the texture characteristics and gray-tone features of real images. This paper presents texture feature analysis of synthetic ultrasound images using local binary patterns (LBP) and demonstrates the usefulness of a set of LBP features for image quality assessment. Experimental results presented in the paper clearly show how these features could provide an accurate quality metric that correlates very well with subjective evaluations performed by clinical experts.


Author(s):  
Awais Nazir ◽  
Muhammad Shahzad Younis ◽  
Muhammad Khurram Shahzad

Speckle noise is one of the most difficult noises to remove especially in medical applications. It is a nuisance in ultrasound imaging systems which is used in about half of all medical screening systems. Thus, noise removal is an important step in these systems, thereby creating reliable, automated, and potentially low cost systems. Herein, a generalized approach MFNR (Multi-Frame Noise Removal) is used, which is a complete Noise Removal system using KDE (Kernal Density Estimation). Any given type of noise can be removed if its probability density function (PDF) is known. Herein, we extracted the PDF parameters using KDE. Noise removal and detail preservation are not contrary to each other as the case in single-frame noise removal methods. Our results showed practically complete noise removal using MFNR algorithm compared to standard noise removal tools. The Peak Signal to Noise Ratio (PSNR) performance was used as a comparison metric. This paper is an extension to our previous paper where MFNR Algorithm was showed as a general purpose complete noise removal tool for all types of noises


2016 ◽  
Vol 24 (5) ◽  
pp. 749-760
Author(s):  
Lei Yang ◽  
Jun Lu ◽  
Ming Dai ◽  
Li-Jie Ren ◽  
Wei-Zong Liu ◽  
...  

2017 ◽  
pp. 761-775
Author(s):  
A.S.C.S. Sastry ◽  
P.V.V. Kishore ◽  
Ch. Raghava Prasad ◽  
M.V.D. Prasad

Medical ultrasound imaging has revolutioned the diagnostics of human body in the last few decades. The major drawback of ultrasound medical images is speckle noise. Speckle noise in ultrasound images is because of multiple reflections of ultrasound waves from hard tissues. Speckle noise degrades the medical ultrasound images lessening the visible quality of the image. The aim of this paper is to improve the image quality of ultrasound medical images by applying block based hard and soft thresholding on wavelet coefficients. Medical ultrasound image transformation to wavelet domain uses debauchee's mother wavelet. Divide the approximate and detailed coefficients into uniform blocks of size 8×8, 16×16, 32×32 and 64×64. Hard and soft thresholding on these blocks of approximate and detailed coefficients reduces speckle noise. Inverse transformation to original spatial domain produces a noise reduced ultrasound image. Experiments on medical ultrasound images obtained from diagnostic centers in Vijayawada, India show good improvements to ultrasound images visually. Quality of improved images in measured using peak signal to noise ratio (PSNR), image quality index (IQI), structural similarity index (SSIM).


Sign in / Sign up

Export Citation Format

Share Document