A Rare Case of Famotidine-Induced Delirium in a Peritoneal Dialysis Patient

2017 ◽  
Vol 37 (1) ◽  
pp. 118-120 ◽  
Author(s):  
Gary C.W. Chan ◽  
K.M. Lee ◽  
Lorraine P.Y. Kwan ◽  
Maggie M.Y. Mok ◽  
Maggie K.M. Ma ◽  
...  

H2 receptor antagonists are commonly employed to manage gastro-esophageal reflux and peptic ulcer diseases with a very low incidence of side effects. Herein, we report an extremely rare incidence of famotidine-induced acute confusion in a patient with end-stage renal failure. We also discuss the pharmacokinetic properties of famotidine and its interplay with compromised renal function to result in neuropsychiatric manifestations, highlighting the importance of dosage adjustment in individuals with renal insufficiency.

2019 ◽  
Vol 10 (02) ◽  
pp. 324-326 ◽  
Author(s):  
Ching Soong Khoo ◽  
Tze Yuan Tee ◽  
Hui Jan Tan ◽  
Raymond Azman Ali

ABSTRACTWe report a patient with end-stage renal disease on peritoneal dialysis, who developed encephalopathy after receiving a few doses of cefepime. He recovered clinically and electroencephalographically after having discontinued the culprit agent and undergone hemodialysis. This case highlights the importance of promptly recognizing this reversible encephalopathy, which can lead to the avoidance of unnecessary workup, reduce the length of hospital stay, and thereby improve the patients’ outcome.


1988 ◽  
Vol 8 (4) ◽  
pp. 249-252 ◽  
Author(s):  
Joanne M. Bargman ◽  
Andre Breborowicz ◽  
Helen Rodela ◽  
Kostas Sombolos ◽  
Dimitrios G. Oreopoulos

Previous protocols of administration of recombinant human erythropoietin to patients with end-stage renal disease have been by the i.v. route. Because this method would be impractical for the continuous ambulatory peritoneal dialysis patient, we designed an i.p. dosing protocol in uremic rabbits to examine whether significant amounts of this hormone could be absorbed from the peritoneal cavity. Our results demonstrate that almost all of the erythropoietin is absorbed (or adsorbed) during a prolonged dwell when administered undiluted by dialysate.


2014 ◽  
Vol 2014 ◽  
pp. 1-4 ◽  
Author(s):  
Sami Safadi ◽  
Michael Mao ◽  
John J. Dillon

Encephalopathy is a rare side effect of third and fourth generation cephalosporins. Renal failure and preexisting neurological disease are notable risk factors. Recognition is important as discontinuing the offending agent usually resolves symptoms. We present a case of acute encephalopathy in a patient with end stage renal disease (ESRD) treated with peritoneal dialysis (PD) who received intravenous ceftriaxone for peritonitis. This case illustrates the potential severe neurologic effects of cephalosporins, which are recommended by international guidelines as first-line antimicrobial therapy for spontaneous bacterial peritonitis.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xueli Lai ◽  
Mingming Nie ◽  
Xiaodong Xu ◽  
Yuanjie Chen ◽  
Zhiyong Guo

Abstract Background Peritoneal dialysis (PD) is a safe and home-based treatment for end-stage renal disease (ESRD) patients. The direct thermal damage of abdominal organs is very rare. Case presentation We report a peritoneal dialysis patient presented abdominal pain and feculent effluent 3 weeks after he instilled hot dialysis solution. In spite of emergency exploratory laparotomy and active treatment, the patient died of septic shock. Biopsy revealed necrosis and perforation of the intestines. Conclusions Delayed bowel perforation by hot fluid is very rare. Standardized performance is of the first importance for peritoneal dialysis patients.


2021 ◽  
pp. 014556132110002
Author(s):  
Soňa Šikolová ◽  
Dagmar Hošnová ◽  
Klára Perceová ◽  
Michal Bartoš ◽  
Vít Kruntorád ◽  
...  

Bonebridge (BB) is the first active implantation system for bone conduction that is placed fully under the skin. Experience suggests that BB is characterized by low incidence of postoperative complications. This case report presents a rare case of a 16-year-old girl with incidence of emphysema occurring over the implant 1 year after operation. We performed a computed tomography scan that showed pockets of gas above the floating mass transducer so we provided the revision surgery and sealed the artificial opening with fat from the earlobe and fibrin glue. Since that time, no air has collected in the retroauricular area and the implant has been fully functional.


Sign in / Sign up

Export Citation Format

Share Document