Application of Digital Remote Wireless Microphone Technology in Single-Sided Deaf Cochlear Implant Recipients

Author(s):  
Thomas Wesarg ◽  
Yvonne Stelzig ◽  
Dan Hilgert-Becker ◽  
Bj¨orn Kathage ◽  
Konstantin Wiebe ◽  
...  
2019 ◽  
Vol 30 (07) ◽  
pp. 607-618 ◽  
Author(s):  
Thomas Wesarg ◽  
Susan Arndt ◽  
Konstantin Wiebe ◽  
Frauke Schmid ◽  
Annika Huber ◽  
...  

AbstractPrevious research in cochlear implant (CI) recipients with bilateral severe-to-profound sensorineural hearing loss showed improvements in speech recognition in noise using remote wireless microphone systems. However, to our knowledge, no previous studies have addressed the benefit of these systems in CI recipients with single-sided deafness.The objective of this study was to evaluate the potential improvement in speech recognition in noise for distant speakers in single-sided deaf (SSD) CI recipients obtained using the digital remote wireless microphone system, Roger. In addition, we evaluated the potential benefit in normal hearing (NH) participants gained by applying this system.Speech recognition in noise for a distant speaker in different conditions with and without Roger was evaluated with a two-way repeated-measures design in each group, SSD CI recipients, and NH participants. Post hoc analyses were conducted using pairwise comparison t-tests with Bonferroni correction.Eleven adult SSD participants aided with CIs and eleven adult NH participants were included in this study.All participants were assessed in 15 test conditions (5 listening conditions × 3 noise levels) each. The listening conditions for SSD CI recipients included the following: (I) only NH ear and CI turned off, (II) NH ear and CI (turned on), (III) NH ear and CI with Roger 14, (IV) NH ear with Roger Focus and CI, and (V) NH ear with Roger Focus and CI with Roger 14. For the NH participants, five corresponding listening conditions were chosen: (I) only better ear and weaker ear masked, (II) both ears, (III) better ear and weaker ear with Roger Focus, (IV) better ear with Roger Focus and weaker ear, and (V) both ears with Roger Focus. The speech level was fixed at 65 dB(A) at 1 meter from the speech-presenting loudspeaker, yielding a speech level of 56.5 dB(A) at the recipient's head. Noise levels were 55, 65, and 75 dB(A). Digitally altered noise recorded in school classrooms was used as competing noise. Speech recognition was measured in percent correct using the Oldenburg sentence test.In SSD CI recipients, a significant improvement in speech recognition was found for all listening conditions with Roger (III, IV, and V) versus all no-Roger conditions (I and II) at the higher noise levels (65 and 75 dB[A]). NH participants significantly benefited from the application of Roger in noise for higher levels, too. In both groups, no significant difference was detected between any of the different listening conditions at 55 dB(A) competing noise. There was also no significant difference between any of the Roger conditions III, IV, and V across all noise levels.The application of the advanced remote wireless microphone system, Roger, in SSD CI recipients provided significant benefits in speech recognition for distant speakers at higher noise levels. In NH participants, the application of Roger also produced a significant benefit in speech recognition in noise.


2020 ◽  
Vol 31 (04) ◽  
pp. 246-256 ◽  
Author(s):  
Thomas Wesarg ◽  
Yvonne Stelzig ◽  
Dan Hilgert-Becker ◽  
Bjorn Kathage ◽  
Konstantin Wiebe ◽  
...  

Abstract Background Previous research showed benefits of remote wireless technology in bilaterally moderate- to-severe hearing-impaired participants provided with hearing aid(s), cochlear implant(s) (CIs), or bimodal devices as well as in single-sided deaf (SSD) cochlear implant recipients (with CI from Cochlear™) and normal-hearing (NH) participants. Purpose To evaluate the effect of the digital remote wireless microphone system, Roger™, on speech recognition at different levels of multisource noise in SSD CI recipients using MED-EL CI sound processor OPUS 2. Outcomes were assessed as a function of the listening condition (NH only, NH + CI, NH + CIRog, NHRog + CI, and NHRog + CIRog), Roger™ receiver type (Roger™ Focus for NH; Roger™ Xand Roger™ MyLink for CI) and accessory mixing ratio. Study Sample Eleven adult, SSD participants aided with CI from MED-EL. Data Collection and Analysis Speech recognition in noise was assessed in two no-Roger™ conditions, one Roger™ X condition, and two Roger™ MyLink conditions. For the Roger™ X and no-Roger™ conditions, speech recognition was tested at 60.3 dB(A) with the Oldenburg Sentence Test in classroom noise at levels of 55, 65, and 75 dB(A). For the two Roger™ MyLink conditions, speech recognition at 60.3 dB(A) was measured at a noise level of 75 dB(A). Roger™ X was assessed with an accessory mixing ratio of 1:1 (summation of unattenuated microphone and audio accessory input). For Roger™ MyLink, two accessory mixing ratios were investigated, MT (1:1, summation of unattenuated microphone and telecoil input) and T with maximum attenuation of microphone input. Results Speech recognition at higher noise levels (65 and 75 dB(A)) improved significantly with Roger™ in both unilateral use conditions (NH + CIRog and NHRog + CI) as well as bilateral use condition (NHRog + CIRog). Both the bilateral application of Roger™ and the unilateral Roger™ application on the NH ear outperformed the Roger™ application on CI alone. There was no statistically significant effect of type of CI Roger™ receiver (Roger™ X or Roger™ MyLink) and the accessory mixing ratio (MT or T) on speech recognition. Conclusions Speech recognition for distant speakers in multisource noise improved significantly with the application of Roger™ in SSD CI recipients. Both the unilateral Roger™ application on the NH ear or the CI as well as the bilateral Roger™ application can be recommended.


2020 ◽  
Vol 63 (12) ◽  
pp. 4325-4326 ◽  
Author(s):  
Hartmut Meister ◽  
Katrin Fuersen ◽  
Barbara Streicher ◽  
Ruth Lang-Roth ◽  
Martin Walger

Purpose The purpose of this letter is to compare results by Skuk et al. (2020) with Meister et al. (2016) and to point to a potential general influence of stimulus type. Conclusion Our conclusion is that presenting sentences may give cochlear implant recipients the opportunity to use timbre cues for voice perception. This might not be the case when presenting brief and sparse stimuli such as consonant–vowel–consonant or single words, which were applied in the majority of studies.


Author(s):  
Martin Chavant ◽  
Alexis Hervais-Adelman ◽  
Olivier Macherey

Purpose An increasing number of individuals with residual or even normal contralateral hearing are being considered for cochlear implantation. It remains unknown whether the presence of contralateral hearing is beneficial or detrimental to their perceptual learning of cochlear implant (CI)–processed speech. The aim of this experiment was to provide a first insight into this question using acoustic simulations of CI processing. Method Sixty normal-hearing listeners took part in an auditory perceptual learning experiment. Each subject was randomly assigned to one of three groups of 20 referred to as NORMAL, LOWPASS, and NOTHING. The experiment consisted of two test phases separated by a training phase. In the test phases, all subjects were tested on recognition of monosyllabic words passed through a six-channel “PSHC” vocoder presented to a single ear. In the training phase, which consisted of listening to a 25-min audio book, all subjects were also presented with the same vocoded speech in one ear but the signal they received in their other ear differed across groups. The NORMAL group was presented with the unprocessed speech signal, the LOWPASS group with a low-pass filtered version of the speech signal, and the NOTHING group with no sound at all. Results The improvement in speech scores following training was significantly smaller for the NORMAL than for the LOWPASS and NOTHING groups. Conclusions This study suggests that the presentation of normal speech in the contralateral ear reduces or slows down perceptual learning of vocoded speech but that an unintelligible low-pass filtered contralateral signal does not have this effect. Potential implications for the rehabilitation of CI patients with partial or full contralateral hearing are discussed.


2004 ◽  
Vol 14 (2) ◽  
pp. 16-20
Author(s):  
Patricia M. Chute ◽  
Helen C. Buhler
Keyword(s):  

ASHA Leader ◽  
2015 ◽  
Vol 20 (3) ◽  
pp. 28-28
Author(s):  
Lisa Satterfield ◽  
Neela Swanson
Keyword(s):  

ASHA Leader ◽  
2005 ◽  
Vol 10 (17) ◽  
pp. 4-13
Author(s):  
Susan Boswell
Keyword(s):  

ASHA Leader ◽  
2009 ◽  
Vol 14 (14) ◽  
pp. 32-32
Author(s):  
Kellie Rowden-Racette

Sign in / Sign up

Export Citation Format

Share Document