Long-term Outcomes and Complications of the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL

2021 ◽  
Vol 37 (2) ◽  
pp. 126-132
Author(s):  
Agostino S. Vaiano ◽  
Kenneth J. Hoffer ◽  
Antonio Greco ◽  
Andrea Greco ◽  
Giovanni D'Amico ◽  
...  
2021 ◽  
pp. 247412642097887
Author(s):  
Gregg T. Kokame ◽  
Tarin T. Tanji ◽  
Jase N. Omizo

Purpose: We report the longest follow-up to our knowledge of stable scleral fixation of a posterior chamber intraocular lens (PC IOL) with 10-0 polypropylene sutures. Methods: A retrospective review is presented of a case with more than 30 years’ follow-up after performing sutured scleral fixation with 10-0 polypropylene suture using 2 sutures tied together under a scleral flap. One suture was a cow-hitch looped around the haptic, and the other suture was passed through the sclera to create the scleral fixation. Results: The scleral fixation with 10-0 polypropylene suture knots for both haptics of the PC IOL allowed central optic positioning with excellent vision for more than 30 years without suture breakage. Conclusions: Polypropylene sutures for scleral fixation of PC IOLs remained stable for more than 30 years with central positioning of the PC IOL, without exposure of the fixation suture knots through the conjunctiva, and without suture breakage.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Rajesh Sinha ◽  
Mohamed Ibrahime Asif ◽  
Nidhi Kalra ◽  
Mayank Bansal ◽  
Divya Chauhan ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-4
Author(s):  
Yong Un Shin ◽  
Mincheol Seong ◽  
Hee Yoon Cho ◽  
Min Ho Kang

Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman’s knot (SFK). Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.


Author(s):  
G.V. Sorokoletov ◽  
◽  
E.R. Tumanyan ◽  
A.N. Bessarabov ◽  
M.A. Soboleva ◽  
...  

Introduction. The use of phakic intraocular lens (PIOL) for the correction of high ametropia is reflected in the works of both domestic and foreign ophthalmologists. In spite of this, there are very few publications which are devoted to the long-term outcomes of the use of domestically produced models of PIOL such as RSK-1(3) and RSK-3. Purpose. The main aim of this work is to assess the clinical and functional outcomes of the use of domestically produced models of PIOL such as RSK-1(3) and RSK-3. Material and methods. A retrospective analysis of the long-term results of PIOL implants performed at the Fyodorov Eye Microsurgery Federal State Institution was carried out from 1994 to 2001. The analysis involved 122 eyes of 84 patients with high myopia from who were implanted with posterior chamber negative PIOL with two haptic elements (RSK-3) and PIOL with three haptic elements (RSK-1(3). Results. Analysis of the dynamics of postoperative refractive data in compare with preoperative parameters showed us that in all cases there was a significant increase in uncorrected and corrected visual acuity. Long-term outcomes of implantation were found in 25 patients (43 eyes). The average duration of PIOL in the eye was 14.30±1.3 g (from 2 to 30 years). In all cases, the reducing cell density of the corneal epithelium did not exceed 4.0% in the early postoperative period. At the same time, the main complication in the distant postoperative period was the development of subcapsular cataracts. Conclusions. This method of ametropia correction can be recommended to young patients, who are not suitable for keratorefraction interventions. Key words: phakic intraocular lens, high myopia.


2021 ◽  
Vol 37 (7) ◽  
pp. 472-476
Author(s):  
Agostino S. Vaiano ◽  
Kenneth J. Hoffer ◽  
Andrea Greco ◽  
Antonio Greco ◽  
Giovanni D'Amico ◽  
...  

2008 ◽  
Vol 44 (2) ◽  
pp. 93
Author(s):  
Hwang-Gyun Kim ◽  
Chul-Woong Cho ◽  
Jae-Kap Cho ◽  
Yeoung-Geol Park ◽  
Kyung-Chul Yoon

2018 ◽  
Vol 101 (5) ◽  
pp. 652-658 ◽  
Author(s):  
Seyed Javad Hashemian ◽  
Nahid Saiepoor ◽  
Leila Ghiasian ◽  
Hossein Aghai ◽  
Mohammad Ebrahim Jafari ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document