Real-Time Estimation of Total Flow Rate and Flow Profiling in DTS-Instrumented Wells

Author(s):  
C.S. Kabir ◽  
B. Izgec ◽  
A.R. Hasan ◽  
U. Minnesota-Duluth ◽  
X. Wang ◽  
...  
2008 ◽  
Author(s):  
C. Shah Kabir ◽  
Bulent Izgec ◽  
A. Hasan ◽  
Xiaowei Wang ◽  
Jaedong Lee

2008 ◽  
Author(s):  
C. Shah Kabir ◽  
Bulent Izgec ◽  
A. Rashid Hasan ◽  
Xiaowei Wang ◽  
Jaedong Lee

2020 ◽  
pp. 039139882098448
Author(s):  
Shuya Shida ◽  
Toru Masuzawa ◽  
Masahiro Osa

Implantable ventricular assist devices are used in heart failure therapy. These devices require real-time flow rate estimation for effective mechanical circulatory support. We previously developed a flow rate estimation method using the eccentric position of a magnetically levitated impeller to achieve real-time estimation. However, dynamic motion of the levitated impeller can compromise the method’s performance. Therefore, in this study, we investigated the effects of dynamic motion of the levitated impeller on the time resolution and estimation accuracy of the proposed method. The magnetically levitated impeller was axially suspended and radially restricted by the passive stability in a centrifugal blood pump that we developed. The dynamic motions of impeller rotation and whirling were analyzed at various operating conditions to evaluate the reliability of estimation. The vibration response curves of the impeller revealed that the resonant rotational speed was 1300–1400 revolutions per minute (rpm). The blood pump was used as a ventricular assist device with rotational speed (over 1800 rpm) sufficiently higher than the resonant speed. The rotor-dynamic forces on the impeller (0.03–0.14 N) suppressed the whirling motion of the impeller, indicating that the dynamic motion could be stable. Although the temporal responsiveness should be determined based on the trade-offs among the estimation accuracy and time resolution, the real-time estimation capability of the proposed method was confirmed.


2016 ◽  
Author(s):  
Mohammad S. Al-Kadem ◽  
Mohammad S. Al Dabbous ◽  
Ali S. Al Mashhad ◽  
Hassan A. Alsadah ◽  
Dhafer Al Shehri

2020 ◽  
Vol 86 (4) ◽  
pp. 61-65
Author(s):  
M. V. Abramchuk ◽  
R. V. Pechenko ◽  
K. A. Nuzhdin ◽  
V. M. Musalimov

A reciprocating friction machine Tribal-T intended for automated quality control of the rubbing surfaces of tribopairs is described. The distinctive feature of the machine consists in implementation of the forced relative motion due to the frictional interaction of the rubbing surfaces fixed on the drive and conjugate platforms. Continuous processing of the signals from displacement sensors is carried out under conditions of continuous recording of mutual displacements of loaded tribopairs using classical approaches of the theory of automatic control to identify the tribological characteristics. The machine provides consistent visual real time monitoring of the parameters. The MATLAB based computer technologies are actively used in data processing. The calculated tribological characteristics of materials, i.e., the dynamic friction coefficient, damping coefficient and measure of the surface roughness, are presented. The tests revealed that a Tribal-T reciprocating friction machine is effective for real-time study of the aforementioned tribological characteristics of materials and can be used for monitoring of the condition of tribo-nodes of machines and mechanisms.


2013 ◽  
Vol 39 (10) ◽  
pp. 1722
Author(s):  
Zhao-Wei SUN ◽  
Wei-Chao ZHONG ◽  
Shi-Jie ZHANG ◽  
Jian ZHANG

Author(s):  
Svetlana Rudyk ◽  
Sami Al-Khamisi ◽  
Yahya Al-Wahaibi

AbstractFactors limiting foam injection for EOR application are exceptionally low rock permeability and exceedingly high salinity of the formation water. In this regard, foam formation using internal olefin sulfonate is investigated over a wide salinity range (1, 5, 8, 10, and 12% NaCl) through 10 mD limestone. The relationships between pressure drop (dP), apparent viscosity, liquid flow rate, total flow rate, salinity, foam texture, and length of foam drops at the outlet used as an indicator of viscosity are studied. Foaming is observed up to 12% NaCl, compared to a maximum of 8% NaCl in similar core-flooding experiments with 50 mD limestone and 255 mD sandstone. Thus, the salinity limit of foam formation has increased significantly due to the low permeability, which can be explained by the fact that the narrow porous system acts like a membrane with smaller holes. Compared to the increasing dP reported for highly permeable rocks, dP linearly decreases in almost the entire range of gas fraction (fg) at 1–10% NaCl. As fg increases, dP at higher total flow rate is higher at all salinities, but the magnitude of dP controls the dependence of apparent viscosity on total flow rate. Low dP is measured at 1% and 10% NaCl, and high dP is measured at 5, 8, and 12% NaCl. In the case of low dP, the apparent viscosity is higher at higher total flow rate with increasing gas fraction, but similar at two total flow rates with increasing liquid flow rate. In the case of high dP, the apparent viscosity is higher at lower total flow rate, both with an increase in the gas fraction and with an increase in the liquid flow rate. A linear correlation is found between dP or apparent viscosity and liquid flow rate, which defines it as a governing factor of foam flow and can be considered when modeling foam flow.


2021 ◽  
Vol 602 ◽  
pp. 120624
Author(s):  
Reza Kamyar ◽  
David Lauri Pla ◽  
Anas Husain ◽  
Giuseppe Cogoni ◽  
Zilong Wang

Sign in / Sign up

Export Citation Format

Share Document