Design and Implementation of Wireless Voltage Monitoring System Based on Zigbee

Author(s):  
Luo Xiaohui

This paper proposed a low cost wireless monitoring system based on ZigBee wireless transmission, and designed a new floating voltage sensor which is suitable for the monitoring of medium voltage and high voltage(MV/HV) public equipment. The system used TI-CC2530 as the controller, proposed a new moving average voltage sensing(MAVS) algorithm by reasonable assumptions, and adopted algorithms to perform the theoretical analysis for the single phase and three-phase voltage. At last, the author carried out a practical experiment on the wireless floating voltage sensor under the voltage up to 30kV, the experimental results showed that the proposed low cost wireless sensor can achieve a good voltage monitoring function, and the error is less than 3%.

2015 ◽  
Vol 135 (3) ◽  
pp. 168-180 ◽  
Author(s):  
Ryota Mizutani ◽  
Hirotaka Koizumi ◽  
Kentaro Hirose ◽  
Kazunari Ishibashi

2013 ◽  
Vol 313-314 ◽  
pp. 1180-1183
Author(s):  
Qi Zhi Fang ◽  
Yong Zhe Ge ◽  
Hong Yu Xu

The elevator monitoring system of elevator is an integrated elevator management platform that can realize fault for alarm, rescuing trapped persons, daily management, quality evaluation and preventing hidden trouble by using C8051f060 MCU as the control core to sensor and collect the elevator operation data, with built-in TCP/IP transport protocol and with HuaWei GTM900C GPRS module to realize all kinds of data monitoring of the elevator, and the transmitting of the data to processing server through the network . This paper mainly introduces the formation of wireless monitoring network system and communication protocol construction, and especially analyzes the function and the system architecture of the wireless communication terminal in real-time monitoring. GPRS can not only satisfy the requirement of real-time elevator monitoring system, with low cost and high reliability but can also effectively avoid a variety of problems that are caused by transmitting the alarm data through cables . This system provides many valuable experiences for the development of unattended system, and it has a broad development prospects.


2014 ◽  
Vol 635-637 ◽  
pp. 1404-1407
Author(s):  
Yuan Xing Zhang ◽  
Fei Li ◽  
Ya Li Shen ◽  
Lei Juan Yang ◽  
Jie Li ◽  
...  

Problems of power quality have been increasingly concerned by the researchers, as the domestic appliances we are usually used are single-phase load, which mainly causes the unbalance of three-phase voltage of power supply. If the induction motor is supplied by three-phase unbalanced voltage, the currents, active and reactive power, efficiency, and losses are affected as the negative-sequence current appears, this paper is emphasized on the induction motor’s characteristics when its’ power supply is three-phase unbalanced voltage by experimental research.


Author(s):  
Kartik Prasad Basu ◽  
Moley Kutty George

Most faults in medium voltage (MV) distribution lines are temporary line to ground (LG) faults. Three-phase auto reclosing (TPAR) is commonly used to remove this fault with temporary disconnection of all the phases. Multi-shot single-phase auto reclosing (SPAR) may also be used to remove the LG fault. But it produces highly unbalanced and low voltage across the load during the reclosure dead time. It is proposed to connect a zigzag winding grounding transformer at the load bus to maintain the 3-phase load voltage when one phase opens during the SPAR. With low value of grounding resistance the 3-phase voltage during the SPAR dead time becomes approximately balanced. Directional over current relays may be used for the protection. Analysis of a MV radial distribution system having a zigzag transformer connected to the remotest load bus is presented with the computation of voltages during the dead time of SPAR.