Design of ECG Acquisition System Based on Matlab

2013 ◽  
Vol 462-463 ◽  
pp. 1001-1004
Author(s):  
Xue Wang ◽  
Wen Liang Niu ◽  
Yuan Sheng Liu

In order to more accurate detection of ECG signal and cost savings, this paper designed a set of ECG signal acquisition system based on Matlab. The system is composed of hardware and software. Hardware is made up of signal acquisition processing circuit and MPC82G516 microcontroller for AD conversion. The software mainly contains configuring Matlab serial to realize communication with MPC82G516 and uses abundant filter resources of Matlab to remove noise by differential, absolute value, smoothing and threshold selection algorithm of R wave detection, R wave peak provides the basis for calculating the heart rate. This paper uses Matlab friendly user interface for displaying received data to make the data more intuitive and read more easily.

2019 ◽  
Vol 27 (6) ◽  
pp. 1354-1361
Author(s):  
郭 健 GUO Jian ◽  
陈雨行 CHEN Yu-hang ◽  
王丽荣 WANG Li-rong ◽  
韦 阳 WEI Yang ◽  
郭 宇 GUO Yu ◽  
...  

2014 ◽  
Vol 33 (12) ◽  
pp. 3673-3696 ◽  
Author(s):  
Filomila Kafe ◽  
Farooq A. Khanday ◽  
Costas Psychalinos

Author(s):  
Rajeev Kumar Pandey ◽  
Jerry Lin ◽  
Paul C.-P. Chao

Abstract This study presents a time-interleave and low DC drift long-time continuous photoplethysmography (PPG) signal acquisition system to obtain accurate measurement of heart rate (HR) in real-time. Time-interleave functionality is used herein to minimize the mispositioning issue. Intensity tuning and transimpedance amplifier gain tuning is used herein to acquire a high-quality PPG signal. The front-end analog readout circuit is designed and implemented by using T18 process. The experimental result shows that the design readout system has the DC settling time of 1 second after the motion artifact. The measured current sensing range is 30nA–10uA. The estimated signal to noise ratio is 68dB@1Hz. The backend pre-signal processing incorporates a new convolution-based moving average filter, signal quality index estimator, and a peak-through detector. The non-invasive PPG sensor is applied to the wrist artery of the 40 healthy subjects for sensing the pulsation of the blood vessel. During the measurement, the subject did not drink (alcohol), eat, smoke or workout. The Measurement results shows that the heart rate accuracy and standard error are 95%, and 0.37±1.96bpm, respectively.


2005 ◽  
Author(s):  
Lingchuan Zhou ◽  
Anthony Bozier ◽  
Jean-Philippe Blonde ◽  
Michel Kraemer ◽  
Jacques Felblinger ◽  
...  

In this paper, the design of a real-time digital multi--channel ECG signal acquisition system is presented. With the purpose of fabrication towards a simple, compact and low-cost tool for bioelectrical signal processing laboratories, the system is developed to acquire the 12 leads EGC signals and converted to numerical data based on an Arduino module named as Leonardo equipped 12 channels ADC. To observe the EGC waves, the ECG signals are amplified through designed amplifiers with the gain of 60 dB. To reduce the effects from the DC component as well as the baseline wandering and the high frequency noise, the active analog bandpass filter ranged in 0,05 Hz to 100 Hz was designed. The power line noise of 50 Hz also decreased with an active analog bandstop filter with attenuation -38 dB. Under the PC application was built using Labview programing, the low-cost digital ECG signal acquisition system was demonstrated with the requirement of observation in real-time. To clarify the small wave in the digital EGG signal, the limitation of the analog signal processing is improved through the digital filters parameterized in the software to increase the SNR from 1.4 dB to 27.6 dB. Practically, the system is evaluated through a series of experiments on a volunteer person resulting the ECG data is recorded and stored in a TDMS file. Since the system is designed as opened-system, a series of developments towards various applications in biomedical diagnosis based on digital signal analysis techniques is promised to be feasible in the near future.


2020 ◽  
Vol 10 (4) ◽  
pp. 890-897
Author(s):  
Huayu Zhao

To realize the design of mobile phone human movement breathing and electrocardiograph (ECG) signal acquisition system based on Bluetooth transmission, the principle of the generation and detection of ECG and respiratory signal and the guide system of signal acquisition are analyzed. Additionally, the hardware of the system is designed, including the hardware of the signal acquisition system, the design of ADS1292R ECG and respiratory signal acquisition module, the design of the main control chip and the design of the Bluetooth module. Then, the digital filtering processing of the ECG and respiratory signals is completed, including the baseline drift filtering and the suppression of the power frequency interference. The results show that the monitoring system runs well and it can effectively collect ECG and respiratory signals, calculate heart rate and respiratory frequency in real time, and display ECG waveform in real time. To sum up, the monitoring system is of great significance for real-time monitoring of the patient's condition.


Author(s):  
Shila Dhande

The system “LabVIEW based ECG signal acquisition and analysis” is developed to assist patients and doctors in health care. An arrhythmia is an abnormal heart rhythm. It may be so brief that it doesn’t change the overall heart rate, but it can cause the heart rate to be too slow or too fast. When arrhythmias are severe or last long enough, the heart may not be able to pump enough blood to the body. This can cause the patient to feel tired, lightheaded or may make him pass out. It can also cause death. Before treatment, it’s important for the doctor to know where an arrhythmia starts in the heart and whether it’s abnormal. An electrocardiogram (ECG) is often used to diagnose arrhythmias. “LabVIEW based ECG signal acquisition and analysis” is meant to acquire ECG signals from the patient and analyze it to detect and classify its anomalies and abnormalities. This is achieved by extracting amplitudes and durations of parameters of ECG waveform such as P wave, QRS complex, RR interval, and PR durations. These parameters are compared with the normal values to determine the type of abnormality- Tachycardia or Bradycardia. The database of the patient is maintained for further use by the doctor. The objective of LabVIEW based ECG signal acquisition and analysis aims at acquiring and analyzing temporal parameters of ECG signal such as P wave, QRS complex, RR interval, PR durations and amplitudes of the P wave, ST wave, identification of cardiac arrhythmia using LabVIEW. The research work has helped us to explore various features of LabVIEW like signal processing and automated database generation.


Sign in / Sign up

Export Citation Format

Share Document