Static Voltage Stability Margin Enhancement Using Shunt Capacitor, SVC and STATCOM

2015 ◽  
Vol 781 ◽  
pp. 288-291 ◽  
Author(s):  
Natakorn Thasnas ◽  
Apirat Siritaratiwat

This paper presents the study of static voltage stability margin enhancement using shunt capacitor, SVC and STATCOM. AC and DC representations of shunt compensation devices are used in the continuation power flow process in static voltage stability study. Various performance measures including PV curves, voltage profiles, and power losses are compared. Placement and sizing techniques of shunt compensation devices are proposed for loading margin enhancement. The study has been carried out on the IEEE 14 bus test system.

2017 ◽  
Vol 5 (10) ◽  
pp. 375-389
Author(s):  
K. Lenin

In this paper, Aeriform Nebula Algorithm (ANA) has been used for solving the optimal reactive power dispatch problem. Aeriform Nebula Algorithm (ANA) is stirred from the deeds of cloud. ANA imitate the creation behavior, modify behavior and expand deeds of cloud. The projected Aeriform Nebula Algorithm (ANA) has been tested on standard IEEE 30 bus test system and simulation results shows clearly about the superior performance of the proposed Aeriform Nebula Algorithm (ANA) in reducing the real power loss and voltage stability has been enhanced.


2014 ◽  
Vol 960-961 ◽  
pp. 1124-1127
Author(s):  
Si Yu Li ◽  
Jia Dong Huang ◽  
Cui Ma

Nowadays, unbalanced loads or nonlinear loads produce a bad effect on the power quality of utility mains. Also, it is necessary for reactive power to be compensated because the most of industrial loads is inductive and make a lagging displacement power factor. Reactive power compensation utilizing STATCOM is one of the most important methods to improve power quality. In this paper, the technical feature of STATCOM is introduced and then a comparison with SVC is made. The effect of STATCOM on static voltage stability in power systems has been studied. Based on PSD-BPA software, effect of STATCOM is determined. Static voltage stability margin enhancement using STATCOM and SVC is compared in the modified IEEE 14-bus test system. Test results show very encouraging result.


2020 ◽  
Vol 5 (12) ◽  
pp. 275-290
Author(s):  
K. Lenin

This paper presents Viral Systems Algorithm (VSA) for solving optimal reactive power problem. VSA have proven to be very efficient when dealing with problems of high complexity. The virus infection expansion corresponds to the feasibility region exploration, and the optimum corresponds to the organism lowest fitness value. Many available algorithms usually present weaknesses and cannot guarantee the optimum output for the problem in a bounded time. Projected Viral Systems Algorithm (VSA) has been tested on standard IEEE 30 bus test system and simulation results show clearly about the superior performance of the proposed Viral Systems Algorithm (VSA) in reducing the real power loss and static voltage stability margin (SVSM) index has been enhanced.


Sign in / Sign up

Export Citation Format

Share Document