Multi-Object Resonant Response Equivalent Static Wind Load of Large-Span Roofs

2011 ◽  
Vol 99-100 ◽  
pp. 1255-1258
Author(s):  
Yu Xue Li ◽  
Qing Shan Yang ◽  
Yu Ji Tian

According to the strain energy equivalent, the resonant response equivalent static wind load of large span roof is derived. It solves the matter that should consider numerous structural response control objects on calculating equivalent static wind load for large span roofs, and establishes relationship with the structural strain energy introduced by fluctuant wind loads. Finally, the method is used to resonant equivalent static wind load analysis of 2008 Beijing Olympic Tennis Center Stadium roof structure. The results illustrate that the method proposed in this paper is effective and the precision is reliable.

2011 ◽  
Vol 99-100 ◽  
pp. 338-341 ◽  
Author(s):  
Yu Xue Li ◽  
Qing Shan Yang ◽  
Yu Ji Tian

Based on strain energy equivalent, the background response equivalent static wind load of large span roof is derived. It solves the matter that should consider numerous structural response control objects on calculating equivalent static wind load of large span roofs, and establishes relationship with the structural strain energy introduced by fluctuant wind loads. Finally, the method is used to background equivalent static wind load analysis of China National Stadium roof structure. The results illustrate that the method proposed in this paper is effective and the precision is reliable.


2013 ◽  
Vol 405-408 ◽  
pp. 1022-1027
Author(s):  
Zi Fen Fang ◽  
Zhi Qiang Zhang ◽  
Fei Liu

The isolation of large-span Steel Truss Roof structure is developed on the basis of base isolation. The isolation of large-span Steel Truss Roof structure is to limit the transmission of wind load effect to the substructure. Based on the engineering background, we mainly discuss using rubber bearing isolation structure wind load effects. This paper will explains and demonstrates the isolation mechanism of Large-span Steel Truss Structure,and than test and verify isolation effect by Calculating through the analysis of wind tunnel tests conducted on the Yancheng financial services center, which the steel truss roof isolation bearings for wind load effect isolation effect.


2014 ◽  
Vol 140 (9) ◽  
pp. 04014061 ◽  
Author(s):  
M. F. Huang ◽  
Wenjuan Lou ◽  
Xiaotao Pan ◽  
C. M. Chan ◽  
Q. S. Li

2018 ◽  
Vol 10 (5) ◽  
pp. 053703 ◽  
Author(s):  
Abhishek Parikh ◽  
Janna Martinek ◽  
Greg Mungas ◽  
Nicholas Kramer ◽  
Guangdong Zhu