Experimental Study on Technical Difficulties of Botswana First Circulating Fluidized Bed Boiler during Loading Process

2013 ◽  
Vol 721 ◽  
pp. 357-362
Author(s):  
Guang Zeng ◽  
Sen Lin Zhao ◽  
Lai Wei ◽  
Run Ze Huang ◽  
Modiri Badirwang

For study of technical difficulties that make Botswana first CFB (Circulating Fluidized Bed) boiler can’t reach full load at beginning of loading process, first experiments were carried out as awful experimental cases to analyze influencing factors; Second experiments were carried out as tentative experimental cases to select useful solutions; Third experiments were carried out as targeted experimental cases to execute chose solutions. Results indicate that one prominent difficulty during CFB boiler reaching full load is that boiler operation bed temperature was too high which was a comprehensive effect with some other influencing factors. CFB boiler bed temperature MFT (Main Fuel Trip) set point slight increasing, grain size changing of both start-up material and feeding coal, limestone injecting, fluidizing air of seal pot and FBHE appropriate controlling and FBHE (Fluid Bed Heat Exchanger) gradually start working are taken simultaneously, all these effective solutions solve the technical difficulties and accelerate the boiler reach full load, but attentions still need to be paid for the boiler stable operation permanently in future.

2014 ◽  
Vol 989-994 ◽  
pp. 256-259
Author(s):  
Jian Meng Yang ◽  
Bi Zheng Wang ◽  
Wei Wang

For study on SO2 and NO emission characteristics of circulating fluidized bed boiler experiments were carried out in a 300MW circulating fluidized bed boiler. In these experiments, the variables were the amount of limestone and bed temperature. While conducting the test, the reasons for the changes in emission were analyzed, and some advices about combustion adjustment were proposed.


2019 ◽  
Vol 118 ◽  
pp. 02011
Author(s):  
Su Pan ◽  
Yu Pengfeng ◽  
Linbo Liu ◽  
Han Jing ◽  
Xiao Shen

The coal as fired, with unidentified characteristics of the coal gangue, was burned on a 300MW circulating fluidized bed unit. The equipment of the coal conveying system was damaged and the boiler operation was unstable. In response to the problems, the coal quality data and storage conditions of the coal were examined and the site was spot-checked to evaluate the coal quality characteristics. At the same time, the typical representative parameters of the coal handling system and boiler operation were selected. According to the analysis of coal quality and coal storage, the coal quality fluctuates greatly and the uniformity of particle size distribution is poor. There is actually the coal gangue with hard texture and hard to grind in the coal pile. The coal gangue will have adverse effects on the fine screening machine, fine crusher and other equipment. After burned this type of coal, the fluidized quality of the boiler bed is degraded to make an impact on the safe and stable operation of the boiler. It is recommended that the coal should be screened and then burned into the furnace to ensure safe and stable operation of the boiler.


2014 ◽  
Vol 1070-1072 ◽  
pp. 1764-1768
Author(s):  
Zhan Guo Li ◽  
Zhen Ning Zhao ◽  
Zhi Qiang Wen

Based on the aspects of thermal properties, resistance properties, air Leakage Control and boiler output adaptability, the operation modes and their impact of a quad-sector rotary airheater adopted by a 330MWe circulating fluidized bed boiler are analyzed by tests. And the operation methods of Leakage Control System are concluded. In order to improve the reliability of rotary airheater with main and auxiliary motors, recommendations for improvement are extended.


Author(s):  
Zhengshun Wu ◽  
Hanping Chen ◽  
Dechang Liu ◽  
Jie Wang ◽  
Chuangzhi Wu ◽  
...  

The operation performance of circulating fluidized bed combustion (CFBC) boiler was studied in this paper. The experimental results indicate that the load of CFB boiler has linear relation with bed temperature and bed material height of operation. By multiple regression analysis, the relation of the load of CFB boiler with bed temperature and bed material height of operation can be expressed as a formula. The suitable temperature and the bed material height corresponding to the load of CFB boiler can be found using the formula; the problem of the boiler to be blindly operated can be reduced in practice.


Sign in / Sign up

Export Citation Format

Share Document