Rheology of Liquid Al, Zn and Zn-7wt%Al Systems

2011 ◽  
Vol 690 ◽  
pp. 226-229 ◽  
Author(s):  
Manickaraj Jeyakumar ◽  
Sumanth Shankar

The flow behavior and viscosity of pure aluminum, zinc and Zn-7wt%Al liquids were quantified with the effects of temperature and shear rate by rotational rheometry experiments. These systems exhibited a non-Newtonian, shear thinning and non-thixotropic flow behavior where in the liquid metal viscosity decreases with increasing shear rates. The temperature dependence of viscosity followed the Arrhenius equation. Moreover, at high shear rate regimes the flow resembles a nearly Newtonian behaviour.

2021 ◽  
Vol 15 (3) ◽  
pp. 181-190
Author(s):  
Elif H Ozcan Cetin ◽  
Mehmet S Cetin ◽  
Mustafa B Ozbay ◽  
Hasan C Könte ◽  
Nezaket M Yaman ◽  
...  

Aim: We aimed to assess the association of whole blood with thromboembolic milieu in significant mitral stenosis patients. Methodology & results: We included 122 patients and classified patients into two groups as having thrombogenic milieu, thrombogenic milieu (+), otherwise patients without thrombogenic milieu, thrombogenic milieu (-). Whole blood viscosity (WBV) in both shear rates were higher in thrombogenic milieu (+) group comparing with thrombogenic milieu (-). WBV at high shear rate and WBV at low shear rate parameters were moderately correlated with grade of spontaneous echo contrast. Adjusted with other parameters, WBV parameters at both shear rates were associated with presence of thrombogenic milieu. Discussion & conclusion: We found that extrapolated WBV at both shear rates was significantly associated with the thrombogenic milieu in mitral stenosis. This easily available parameter may provide additional perspective about thrombogenic diathesis.


1989 ◽  
Vol 13 (2) ◽  
pp. 97-102 ◽  
Author(s):  
B. B. Gupta ◽  
L. H. Ding ◽  
M. Y. Jaffrin

1967 ◽  
Vol 40 (5) ◽  
pp. 1483-1491
Author(s):  
Yoshio Ito

Abstract Nonnewtonian flow of poly(dimethyl siloxanes) of various molecular weights has been studied with a short capillary viscosimeter. The experiment covered a wide range of shear rate, from 10−1 to 3×106sec−1. Results were as follows: (1) Flow behavior of the sample changes with the degree of polymerization. For siloxanes with degrees of polymerization less than 1.55×102, flow of the fluid is newtonian throughout the whole range of shear rates; for siloxanes with degrees of polymerization from 3.22×102 to 2.63×103, flow is nonnewtonian at moderate shear rates; it again becomes newtonian at high shear rates. With degrees of polymerization more than 3.31×103, the spiral flow rises to a high shear rate. (2) Plow behavior of the samples is expressed by modifying Shishido's equation proposed for nonnewtonian polymer solutions. (3) When the observed flow curve contains its inflection point, the upper newtonian viscosity can be estimated by a new method proposed here. (4) The relations among the end correction of capillary, the pressure loss, and the shear stress proposed by Shishido for polymer solutions are applicable to poly(dimethy! siloxane) also.


2021 ◽  
Author(s):  
◽  
Stefan Kuczera

<p>A flow phenomena called ‘shear banding’ is often observed for a certain class of complex fluids, namely wormlike micellar solutions. Wormlike micelles are elongated flexible self-assembly structures formed by the aggregation of amphiphiles, which may entangle into a dynamic network above a certain concentration threshold. The entanglement results in the sample having both solid-like (elastic) and liquid-like (viscous) properties, an ambiguity commonly found in complex fluids. Under certain shear conditions, the flow couples with the structure of the micellar network, leading to the formation of (shear) bands with differing viscosity.  The principle goal of this work is to address open questions regarding the temporal and spatial stability of shear banded flow. Shear banding is often studied in cylindrical Couette cells, where the fluid is sheared in a gap between differentially rotating concentric cylinders. For the sake of an accurate description of the flow in such a shear cell, the methodology for a 2D Nuclear Magnetic Resonance (NMR) velocimetry technique (known as PGSE-RARE), which offers high temporal and spatial resolution, is improved and refined. Two main challenges are identified and overcome. The first concerns the fact that the velocity imaging process operates on a Cartesian grid, whereas the flow in the Couette cell is of cylindrical symmetry. Numerical calculations and NMR simulations based on the Bloch equations, as well as experimental evidence, give insight on the appropriate selection of the fluid volume over which velocity information is accumulated and the preferred scheme through which the NMR image is acquired in the so-called k-space. The small extent of the fluid gap for the cells in use is the second challenge. In this respect, a variant of the velocimetry technique is developed, which offers ultra high resolution in the gap direction, necessary for a detailed description of the flow profile in the banded state.  The refined methodology is applied in a thorough study of a certain wormlike micellar solution (‘10% CPCl’), which is known to exhibit spatiotemporal fluctuations and has been subject of numerous studies over the past 20 years. NMR results are supported by a recently developed 2D Rheo-USV (Ultrasonic Speckle Velocimetry) method, which offers an even higher temporal resolution. The two complementary methods show good agreement for averaged velocity profiles. In line with previous studies the fluid is found to follow a standard anomalous lever rule, which is characterized by a constant shear rate in the high viscosity band and a varying shear rate and proportion of the high shear rate band. In particular, the high resolution NMR variant allows a refined picture on the dynamics of the interface between the two bands. Furthermore, slip is observed for all investigated shear rates. The amount of slip, however, is found to strongly depend on the specifities of the Couette cells in use. Spatially and temporally resolved flow maps reveal various flow instabilities. Ultrasound measurements show vorticity structures in the order of the gap width. In the NMR case no such structures are observed due to the lower resolution in the axial direction. For higher shear rates the occurrence of turbulent bursts is detected for USV. No direct evidence of similar flow instabilities is found in the NMR case. Finally, broad distributions dominate the high shear rate band in temporally and spatially resolved velocity profiles, showing the fluctuative nature of the flow.</p>


2018 ◽  
Vol 5 (1) ◽  
Author(s):  
Marcio Da Silva Coutinho ◽  
Danielle Cristina Fernandes Da Silva ◽  
Gustavo Ribeiro Xavier ◽  
Norma Gouvêa Rumjanek ◽  
Paulo Jansen De Oliveira

The rheological behavior of the carboxymethylcellulose (CMC) / starch blends with and without zinc oxide (ZnO) have been investigated by controlled shear rate testing ramps. All blends showed high shear thinning flow behavior, (n=0,10 - 0,32) without ZnO and (n=0,10-0,29) with ZnO. The consistency index (K) and apparent viscosity (ηa,100 ) decreased with increasing amount of starch and with the addition of 1% wt ZnO. The results also showed that occurs an inversion in the elastic and viscous modulii behavior between 25 and 700C, obeying the Arrhenius equation. The study of activation energy showed that ZnO acts in the CMC phase, increase of viscosity of mixtures. The creep and recovery test indicated a decrease in the viscosity zero shear rate, indicating an increase of viscous character.  The phase angle results also confirm an increase of viscosity with addition of ZnO.


2021 ◽  
Author(s):  
◽  
Stefan Kuczera

<p>A flow phenomena called ‘shear banding’ is often observed for a certain class of complex fluids, namely wormlike micellar solutions. Wormlike micelles are elongated flexible self-assembly structures formed by the aggregation of amphiphiles, which may entangle into a dynamic network above a certain concentration threshold. The entanglement results in the sample having both solid-like (elastic) and liquid-like (viscous) properties, an ambiguity commonly found in complex fluids. Under certain shear conditions, the flow couples with the structure of the micellar network, leading to the formation of (shear) bands with differing viscosity.  The principle goal of this work is to address open questions regarding the temporal and spatial stability of shear banded flow. Shear banding is often studied in cylindrical Couette cells, where the fluid is sheared in a gap between differentially rotating concentric cylinders. For the sake of an accurate description of the flow in such a shear cell, the methodology for a 2D Nuclear Magnetic Resonance (NMR) velocimetry technique (known as PGSE-RARE), which offers high temporal and spatial resolution, is improved and refined. Two main challenges are identified and overcome. The first concerns the fact that the velocity imaging process operates on a Cartesian grid, whereas the flow in the Couette cell is of cylindrical symmetry. Numerical calculations and NMR simulations based on the Bloch equations, as well as experimental evidence, give insight on the appropriate selection of the fluid volume over which velocity information is accumulated and the preferred scheme through which the NMR image is acquired in the so-called k-space. The small extent of the fluid gap for the cells in use is the second challenge. In this respect, a variant of the velocimetry technique is developed, which offers ultra high resolution in the gap direction, necessary for a detailed description of the flow profile in the banded state.  The refined methodology is applied in a thorough study of a certain wormlike micellar solution (‘10% CPCl’), which is known to exhibit spatiotemporal fluctuations and has been subject of numerous studies over the past 20 years. NMR results are supported by a recently developed 2D Rheo-USV (Ultrasonic Speckle Velocimetry) method, which offers an even higher temporal resolution. The two complementary methods show good agreement for averaged velocity profiles. In line with previous studies the fluid is found to follow a standard anomalous lever rule, which is characterized by a constant shear rate in the high viscosity band and a varying shear rate and proportion of the high shear rate band. In particular, the high resolution NMR variant allows a refined picture on the dynamics of the interface between the two bands. Furthermore, slip is observed for all investigated shear rates. The amount of slip, however, is found to strongly depend on the specifities of the Couette cells in use. Spatially and temporally resolved flow maps reveal various flow instabilities. Ultrasound measurements show vorticity structures in the order of the gap width. In the NMR case no such structures are observed due to the lower resolution in the axial direction. For higher shear rates the occurrence of turbulent bursts is detected for USV. No direct evidence of similar flow instabilities is found in the NMR case. Finally, broad distributions dominate the high shear rate band in temporally and spatially resolved velocity profiles, showing the fluctuative nature of the flow.</p>


2016 ◽  
Vol 138 (8) ◽  
Author(s):  
Gaku Tanaka ◽  
Ryuhei Yamaguchi ◽  
Hao Liu ◽  
Toshiyuki Hayase

For laminar flow in the side branch of a T-junction, periodic fluid vibrations occur with the Strouhal number independent of characteristic flow conditions. As the mechanics is unknown, an experiment was performed to establish the underlying cause in high-shear-rate flow. The fluid vibration appears along both the shearing separation layer and the boundary between two vortices immediately downstream of the side branch, where the shear rates are several orders larger than those further downstream. This vibration is caused by flow instability induced in two types of high-shear-rate flow confirming that is a universal phenomenon associated with the geometry of the T-junction.


2009 ◽  
Vol 74 ◽  
pp. 81-84 ◽  
Author(s):  
H. Berthet ◽  
H. Stone ◽  
F. Marty ◽  
B. Mercier ◽  
J. Jundt ◽  
...  

We present our efforts to design, manufacture, and characterize a capillary viscometer aimed at performing very high shear rate rheology of complex fluids, and fabricated using hybrid MEMS/microfluidic technology. We demonstrate that microfluidic and MEMS technologies can be combined to integrate fluidic channels with microfabricated stress and flow sensors, enabling rheological measurements at shear rates up to 500000s-1 and beyond.


1988 ◽  
Vol 2 (2) ◽  
pp. 159-167 ◽  
Author(s):  
K.R. Holme ◽  
L.D. Hall ◽  
R.A. Speers ◽  
M.A. Tung

2011 ◽  
Vol 106 (12) ◽  
pp. 1062-1068 ◽  
Author(s):  
Naoki Tsuji ◽  
Yuko Honda ◽  
Chikako Kamisato ◽  
Yoshiyuki Morishima ◽  
Toshiro Shibano ◽  
...  

SummaryEdoxaban is an oral, direct factor Xa (FXa) inhibitor under late-phase clinical development. This study compared the antithrombotic efficacy of edoxaban with that of an indirect FXa inhibitor, fondaparinux, in in vivo venous and arterial thrombosis models and in ex vivo perfusion chamber thrombosis model under low and high shear rates in rats. Venous and arterial thrombi were induced by platinum wire insertion into the inferior vena cava and by application of FeCl3 to the carotid artery, respectively. The perfusion chamber thrombus was formed by blood perfusion into a collagen-coated capillary at 150 s-1 (low shear rate) and 1,600 s-1 (high shear rate). Effective doses of edoxaban that reduced thrombus formation by 50% (ED50) in venous and arterial thrombosis models were 0.076 and 0.093 mg/kg/h, respectively. In contrast, ED50 of fondaparinux in the arterial thrombosis model (>10 mg/kg/h) was markedly higher compared to ED50 in the venous thrombosis model (0.021 mg/kg/h). In the perfusion chamber thrombosis model, the ratio of ED50 under high shear rate (1.13 mg/kg/h) to that under low shear rate (0.63 mg/kg/h) for edoxaban was 1.9, whereas that for fondaparinux was more than 66. While the efficacy of fondaparinux markedly decreased in arterial thrombosis and in a high-shear state, edoxaban exerted consistent antithrombotic effects regardless of flow conditions. These results suggest that shear rate is a key factor in different antithrombotic effects between edoxaban and fondaparinux.


Sign in / Sign up

Export Citation Format

Share Document