scholarly journals Development and validation of an high-performance liquid chromatographic, and a ultraviolet spectrophotometric method for determination of Ambroxol hydrochloride in pharmaceutical preparations

Author(s):  
Selvadurai Muralidharan ◽  
SokkalingamArumugam Dhanara ◽  
JayaRaja Kumar
2011 ◽  
Vol 2011 ◽  
pp. 1-4
Author(s):  
Selvadurai Muralidharan ◽  
Subramania Nainar Meyyanathan

A high-performance liquid chromatographic (HPLC) and a ultraviolet (UV) methods were developed and validated for the quantitative determination of Dexibuprofen (DI) in pharmaceutical dosage form. HPLC was carried out by reversed phase technique on a RP-18 column with a mobile phase composed of acetonitrile and 0.5% triethylamine (pH 7.5 adjusted with orthophosphoric acid (30 : 70, v/v)). UV method was performed with the λ max at 222.0 nm. Both the methods showed good linearity, reproducibility and precision. No spectral or chromatographic interferences from the tablet excipients were found in UV and HPLC. The method was successfully applied to commercial DEXIFEN tablets. Validation parameters such as linearity, precision, accuracy, and specificity were determined. The proposed method could be applicable for routine analysis of DI and monitoring of the quality of marketed drugs.


Author(s):  
Kuntal Mukherjee ◽  
S. T. Narenderan ◽  
B. Babu ◽  
Survi Mishra ◽  
S. N. Meyyanathan

A simple, sensitive and rapid high performance liquid chromatographic method has been developed for the determination of Propofol. The main focus of the method was to determine Propofol in solution form as well as in marketed formulation. Chromatographic separation was achieved on Inertsil ODS-3V column (250mm x 4.6mm; 5µm) with a mobile phase consisting of methanol: water (85:15), with a flow rate of 1.0ml/min (UV detection at 270nm). Linearity was observed over the concentration range of 10-110µg/ml with a regression equation y=88048x + 44524 and having a regression value (R2) of 0.999. The LOD and LOQ values found to be 10ng and 100ng, respectively. No changes found in ruggedness and robustness studies. The percentage of recovery was found to be 95.25% to 101.81%. Validation studies revealed that the method was specific, accurate, precise, reliable, robust, reproducible and suitable for the quantitative analysis in its pharmaceutical formulations.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


2009 ◽  
Vol 74 (12) ◽  
pp. 1455-1465 ◽  
Author(s):  
Valéria Guzsvány ◽  
Zsigmond Papp ◽  
Sanja Lazic ◽  
Ferenc Gaál ◽  
Luka Bjelica ◽  
...  

A simple first-order derivative spectrophotometric method was developed for the simultaneous determination of imidacloprid and 6-chloronicotinic acid (6-CNA). By using the zero-crossing approach, imidacloprid was determined at 249 nm and 6-CNA at 236 nm with detection limits of 0.32 and 0.17 ?g mL-1, respectively, and relative standard deviations not exceeding 1.2 % in the case of model systems. The proposed method was applied for the determination of imidacloprid and 6-CNA in commercial formulations. A conventional spectrophotometric method (at 270 nm) was also employed for the determination of the content of imidacloprid in the same commercial formulations. The results of the developed spectrophotometric methods were in good agreement with those obtained by the high-performance liquid chromatographic method.