scholarly journals Thrombus formation in the right atrium after surgical closure of atrial septal defect

2018 ◽  
Vol 28 (4) ◽  
pp. 242
Author(s):  
Muzaffer Kahyaoğlu ◽  
Ahmet Guner ◽  
Cetin Gecmen
2005 ◽  
Vol 8 (2) ◽  
pp. 96 ◽  
Author(s):  
Osman Tansel Dar�in ◽  
Alper Sami Kunt ◽  
Mehmet Halit Andac

Background: Although various synthetic materials and pericardium have been used for atrial septal defect (ASD) closure, investigators are continuing to search for an ideal material for this procedure. We report and evaluate a case in which autologous right atrial wall tissue was used for ASD closure. Case: In this case, we closed a secundum ASD of a 22-year-old woman who also had right atrial enlargement due to the defect. After establishing standard bicaval cannulation and total cardiopulmonary bypass, we opened the right atrium with an oblique incision in a superior position to a standard incision. After examining the secundum ASD, we created a flap on the inferior rim of the atrial wall. A stay suture was stitched between the tip of the flap and the superior rim of the defect, and suturing was continued in a clockwise direction thereafter. Considering the size and shape of the defect, we incised the inferior attachment of the flap, and suturing was completed. Remnants of the flap on the inferior rim were resected, and the right atrium was closed in a similar fashion. Results: During an echocardiographic examination, neither a residual shunt nor perigraft thrombosis was seen on the interatrial septum. The patient was discharged with complete recovery. Conclusion: Autologous right atrial patch is an ideal material for ASD closure, especially in patients having a large right atrium. A complete coaptation was achieved because of the muscular nature of the right atrial tissue and its thickness, which is a closer match to the atrial septum than other materials.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
I Marco Clement ◽  
R Eiros ◽  
R Dalmau ◽  
T Lopez ◽  
G Guzman ◽  
...  

Abstract Introduction The diagnosis of sinus venosus atrial septal defect (SVASD) is complex and requires special imaging. Surgery is the conventional treatment; however, transcatheter repair may become an attractive option. Case report A 60 year-old woman was admitted to the cardiology department with several episodes of paroxysmal atrial flutter, atrial fibrillation and atrioventricular nodal reentrant tachycardia. She reported a 10-year history of occasional palpitations which had not been studied. A transthoracic echocardiography revealed severe right ventricle dilatation and moderate dysfunction. Right volume overload appeared to be secondary to a superior SVASD with partial anomalous pulmonary venous drainage. A transesophageal echocardiography confirmed the diagnosis revealing a large SVASD of 16x12 mm (Figure A) with left-right shunt (Qp/Qs 2,2) and two right pulmonary veins draining into the right superior vena cava. Additionally, it demonstrated coronary sinus dilatation secondary to persistent left superior vena cava. CMR and cardiac CT showed right superior and middle pulmonary veins draining into the right superior vena cava 18 mm above the septal defect (Figures B and C). After discussion in clinical session, a percutaneous approach was planned to correct the septal defect and anomalous pulmonary drainage. For this purpose, anatomical data obtained from CMR and CT was needed to plan the procedure. During the intervention two stents graft were deployed in the right superior vena cava. The distal stent was flared at the septal defect level so as to occlude it while redirecting the anomalous pulmonary venous flow to the left atrium (Figure D). Control CT confirmed the complete occlusion of the SVASD without residual communication from pulmonary veins to the right superior vena cava or the right atrium (Figure E). Anomalous right superior and middle pulmonary veins drained into the left atrium below the stents. Transthoracic echocardiographies showed progressive reduction of right atrium and ventricle dilatation. The patient also underwent successful ablation of atrial flutter and intranodal tachycardia. She is currently asymptomatic, without dyspnea or arrhythmic recurrences. Conclusions In this case, multimodality imaging played a key role in every stage of the clinical process. First, it provided the diagnosis and enabled an accurate understanding of the patient’s anatomy, particularly of the anomalous pulmonary venous connections. Secondly, it allowed a transcatheter approach by supplying essential information to guide the procedure. Finally, it assessed the effectiveness of the intervention and the improvement in cardiac hemodynamics during follow-up. Abstract P649 Figure.


2020 ◽  
pp. 1-3
Author(s):  
Christopher Herron ◽  
Daisuke Kobayashi

Abstract Transcatheter device closure of an atrial septal defect (ASD) may require an additional supportive technique in challenging cases. We report a 15-year-old male with moderate-sized ASD and severe scoliosis. In spite of adequate positioning of the Gore Cardioform ASD occluder, the device was pulled into the right atrium by a retrieval cord due to the acute release of strong tension between the delivery catheter and its device upon locking. This phenomenon was prevented by the use of Mullins sheath, resulting in a successful release of the device. The use of a Mullins sheath may be considered to deliver a Gore Cardioform ASD device in selected cases.


2017 ◽  
Vol 32 (8) ◽  
pp. 476-478 ◽  
Author(s):  
Rahul Kumar Bhukar ◽  
Deepak Gowda ◽  
Jinaga Nageswar Rao ◽  
Neelam Desai

2004 ◽  
Vol 14 (5) ◽  
pp. 481-487 ◽  
Author(s):  
Clifford L. Cua ◽  
Elizabeth E. Sparks ◽  
David P. Chan ◽  
Curt J. Daniels

Atrial arrhythmias are associated with enlarged atrial chambers and an increased duration of the P wave. Repair of atrial defects within the oval fossa is expected to normalize atrial size. Few studies, however, have evaluated electrical and morphological atrial features after repair. Our study was performed to determine if atrial abnormalities exist after surgical closure of such atrial septal defects, and whether early closure improves outcome. We recruited patients who had undergone surgical closure of a defect within the oval fossa, so-called “secundum” atrial septal defects. Electrocardiograms, signal averaged electrocardiograms, and echocardiograms were performed. Two-tailed test and Pearson correlation was utilized for statistical analysis. The population consisted of 20 patients and 27 controls, with the mean age of the patient being 11.25 ± 5.10 years, their age at surgery 6.55 ± 5.10 years, and the time since surgery 4.70 ± 2.61 years. The size of the right (23.88 ± 6.35 ml/m2 versus 18.84 ± 4.43 ml/m2) and left (21.91 ± 12.47 ml/m2 versus 17.72 ± 4.83 ml/m2) atrium were significantly larger in the patients. The duration of the P wave (108 ± 16 ms versus 96 ± 8 ms) and the duration of the PR interval (155 ± 18 ms versus 138 ± 23 ms) were longer. No correlation existed between age or interval since surgery with atrial sizes or measurements of the signal averaged electrocardiogram. We conclude that, despite surgical repair, abnormalities exist in patients with an atrial septal defect. Early surgery does not appear to prevent the atrial abnormalities.


2014 ◽  
Vol 17 (4) ◽  
pp. 234 ◽  
Author(s):  
Ling Yunfei ◽  
Li Dongxu ◽  
Luo Shuhua ◽  
Wang Yabo ◽  
Deep San ◽  
...  

We describe the case of a 19-year-old Chinese woman who nine months prior underwent repair of an atrial septal defect and came to our hospital with a right atrial mass attached to the anterior wall of the right atrium on transthoracic echocardiography. Pathologic examination revealed the mass was a mixed-type thrombosis with some unusual organization, which previously was not described in literature.


2018 ◽  
Vol 2018 ◽  
pp. 1-4 ◽  
Author(s):  
Yao Liu ◽  
Gai-Li Guo ◽  
Feng-Wen Zhang ◽  
Bin Wen ◽  
Wen-Bin Ou-Yang ◽  
...  

Objective. To assess the effectiveness of a novel ultrasound wire for echo-guiding percutaneous atrial septal defect (ASD) closure in a sheep model. Methods. After right lateral thoracotomy, ASDs were created in 20 sheep by transseptal needle puncture followed by balloon dilatation. Animals were evenly randomized into 2 groups to undergo ASD closure using echography as the only imaging tool with either COOK wire (control group) or new ultrasound wire (study group). The total procedural time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into the right atrium, frequency of arrhythmias, and 1-week rate of complications were compared between the two groups. Results. All animals survived defect creation procedures uneventfully. ASD devices were successfully implanted in all sheep. Compared with the control group, the study group had significantly (P<0.05) lower mean procedure time (15.36 ± 4.86 versus 25.82 ± 7.85 min), lower mean passing time (2.69 ± 0.82 versus 5.58 ± 3.34 min), lower frequency of the guide wire dropping into the right atrium (0% versus 40%), and lower frequency of atrial (4.41 ± 2.61 versus 9.60 ± 3.68) or ventricular premature contractions (0.75 ± 0.36 versus 1.34 ± 0.68), respectively, without serious complications up to one week. Conclusion. The novel ultrasound specialized guide wire was effective in echo-guiding percutaneous ASD closure.


Sign in / Sign up

Export Citation Format

Share Document