scholarly journals A Comparative Evaluation of Smear Layer Removal Using Apical Negative Pressure (EndoVac), Sonic Irrigation (EndoActivator) and Er:YAG laser -An In Vitro SEM Study

Author(s):  
S Suman ◽  
P Verma ◽  
A Prakash-Tikku ◽  
R Bains ◽  
V Kumar-Shakya
2021 ◽  
Vol 22 (5) ◽  
pp. 527-531
Author(s):  
Saurabh Mankeliya ◽  
Neha Jaiswal ◽  
Rajnish K Singhal ◽  
Anushri Gupta ◽  
Vivek K Pathak ◽  
...  

2013 ◽  
Vol 14 (6) ◽  
pp. 1028-1035
Author(s):  
Sangeetha Vallikanthan ◽  
K Balakoti Reddy ◽  
Shreemoy Dash ◽  
Sowmya Kallepalli ◽  
N Chakrapani ◽  
...  

ABSTRACT Objectives The present study was conducted to compare the cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper). Materials and methods Sixty single rooted human maxillary anterior teeth decoronated at the cementoenamel junction were used. All the specimens were divided into four groups of 15 teeth each, group I—ProTaper rotary instrumentation done, group II—K3 rotary instrumentation done, group III—Stainless steel K-file instrumentation done, group IV—root canal irrigation without instrumentation. Root canal preparation was done in a crown down manner and 3% sodium hypochlorite was used as irrigant after each file followed by final rinse with 5 ml of 17% EDTA solution, then specimens were scanning electron microscopic (SEM) examination. Results Statistical analysis was done using one-way ANOVA followed by post hoc Tukey's HSD test. Group I showed highly statistical significant difference compared to other groups. There was no statistically significant difference considering smear layer at any levels among the groups with no smear layer formation in group IV. Conclusion ProTaper rotary instrumentation showed the maximum cleaning efficacy followed by K3 rotary instrumentation in the coronal, middle and apical thirds of the root canal. Clinical significance ProTaper rotary instruments are more efficient than hand and K3 rotary instruments during root canal treatment. How to cite this article Reddy KB, Dash S, Kallepalli S, Vallikanthan S, Chakrapani N, Kalepu V. A Comparative Evaluation of Cleaning Efficacy (Debris and Smear Layer Removal) of Hand and Two NiTi Rotary Instrumentation Systems (K3 and ProTaper): A SEM Study. J Contemp Dent Pract 2013;14(6):1028-1035.


2003 ◽  
Author(s):  
Aldo Brugnera, Jr. ◽  
Danilo M. Zanello Guerisoli ◽  
Melissa A. Marchesan ◽  
Julio C. Emboava Spano ◽  
Jesus Djalma Pecora

2003 ◽  
Author(s):  
Alexandre Capelli ◽  
Aldo Brugnera, Jr. ◽  
Fabio Heredia Seixas ◽  
Melissa A. Marchesan ◽  
Danilo M. Zanello Guerisoli ◽  
...  

2003 ◽  
Vol 1248 ◽  
pp. 269-271
Author(s):  
Aldo Brugnera ◽  
Danilo Mathias Zanello Guerisoli ◽  
Melissa A. Marchesan ◽  
Julio Cesar E. Spano ◽  
Jesus Djalma Pecora

Sign in / Sign up

Export Citation Format

Share Document