scholarly journals Implantable Collamer Lens for Correction of Refractive Errors in Patients with Keratoconus following Collagen Cross-Linking: One Year Follow-up

Author(s):  
Hassenien Safa Shuber

ABSTRACT Objective The purpose of this study is to assess the predictability, safety, efficacy and stability of correction of refractive errors in patients with keratoconus using Visian implantable collamer lens (ICL) following collagen cross-linking. Materials and methods This prospective, non-comparative study evaluated 20 eyes of 14 patients with keratoconus subjected to implantation of intraocular collamer lens at least 1 year following collagen cross-linking and stable refraction. Mean preoperative myopia was −8.43 ± 5.13 Diopters (D) (–3.5 to −20.0D and mean cylinder was −2.19 ± 1.28D (0.0 to −4.5D). The preoperative spherical equivalent (SE) was −9.52 ± 5.33D (–3.75 to −21.25D). During the 12 months follow-up, uncorrected visual acuity, best corrected visual acuity, refraction, intraocular pressure and vaulting are measured. Results At 12 months postoperatively, 90% of eye had refractive cylinder of <1.0D with (p = 0.003) and 20 (100%) eyes was within ±0.75D of sphere at 1 year (r2 = 0.99) and (p = 0.0085). The mean postoperative BCVA in decimal was 0.498 ± 0.232, while the mean preoperative BCVA was 0.484 ± 0.285. The safety index at 12 months was 1.02. The mean postoperative UCVA in decimal was 0.498 ± 0.232 and the mean preoperative BCVA is 0.484 ± 0.29 and the efficacy index at 12 months was 1.01. Conclusion Implantation of Visian Intraocular collamer lens is predictable, safe and effective way to correct refractive error in patients with keratoconus following collagen cross-linking. How to cite this article Shuber HS. Implantable Collamer Lens for Correction of Refractive Errors in Patients with Keratoconus following Collagen Cross-Linking: One Year Follow-up. Int J Kerat Ect Cor Dis 2014;3(1):29-35.

Author(s):  
Dimitrii Dementiev ◽  
Maria Sysoeva ◽  
Anna Shipunova

ABSTRACT Purpose To evaluate safety, efficacy, and stability of cross-linking (CLX) procedure as a method for keratoconus treatment in the I and II stage of disease. Materials and methods Twenty eyes of 15 patients (13 males, 2 females, average age 31 years) with keratoconus I stage (13 eyes) and II stage (2 eyes) (by Krumeich classi­fication) were treated by CLX procedure, using riboflavin Medio Cross for standard CLX); riboflavin Medio Cross TE for transepithelial CLX was used to treat keratectasia after previous keratorefractive surgery; in all the cases UV CBM X linker (Vega, CSO) was used. The study included evaluation of uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA) pre- and postoperative, pachymetry (central cornea thickness) (Visante OCT, Zeiss) pre- and postoperative, total astigmatism pre- and postoperative, using keratotopography (Atlas, Zeiss). Diagnosis and analysis have been performed at the International Center for Ophthalmology in Moscow, Russian ­Federation, since 2012 to 2014 years. Follow-up period was from 1 to 24 months. Results Average UCVA preoperative was 0.4 (Decimal), and average BCVA was 0.64. Average UCVA postoperative was 0.49; average BCVA was 0.66. Total astigmatism preoperative was 2.81 D; total astigmatism postoperative 2.80 D. Central cornea thickness (CCT) preoperative 454 mkm; CCT post­operative 447 mkm. Conclusion Cross-linking indicated safety, stability, and efficacy for treatment of I and II stage keratoconus at the end of follow-up period. Cross-linking is not effective in the treatment of II and III stage of disease. Further study is required. How to cite this article Dementiev D, Sysoeva M, Shipunova A. Two Years’ Experience in Keratoconus Treatment using Collagen Cross-linking. Int J Kerat Ect Cor Dis 2017;6(1):11-13.


2009 ◽  
Vol 19 (4) ◽  
pp. 535-543 ◽  
Author(s):  
Leopoldo Spadea ◽  
Massimo Saviano ◽  
Angela Di Gregorio ◽  
Domenico Di Lodovico ◽  
Fabio De Sanctis

Purpose To evaluate in a long-term period the effectiveness and safety of topographically guided two-step laser in situ keratomileusis (LASIK) and standard LASIK technique in the correction of refractive errors after successful penetrating keratoplasty (PKP) for keratoconus. Methods At least 2 years after PKP and 6 months after removal of all sutures, 15 eyes of 15 patients (Group 1; mean manifest refraction spherical equivalent (MRSE) −7.23 D ± 3.42 SD) were submitted to standard LASIK and 15 eyes of 15 patients (Group 2; mean MRSE −4.37 D ± 1.97 SD) to a topographically guided two-step LASIK procedure (first the flap and at least 2 weeks later the laser ablation). In all cases, a superior hinged corneal flap (160 μm/9.5 mm) was created. Results After a follow-up of 36 months, in Group 1 the mean uncorrected visual acuity (UCVA) was 0.51 logarithm of the minimum angle of resolution (logMAR) ± 0.41 SD and the mean best-corrected visual acuity (BCVA) was 0.03 logMAR ± 0.05 SD, with a mean MRSE of −1.57 D ± 2.65 SD. In Group 2, the mean UCVA was 0.28 logMAR ± 0.24 SD and the mean BCVA was 0.01 logMAR ± 0.03 SD, with a mean MRSE of −0.07 D ± 1.00 SD. In both groups, no complications were observed. Conclusions After a long follow-up period, both topographically guided two-step LASIK and standard LASIK could be considered effective and safe tools in the correction of refractive errors after successful PKP for keratoconus.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Sri Ganesh ◽  
Sheetal Brar

Purpose. To study the safety and clinical outcomes of ReLEx SMILE with accelerated cross-linking in individuals with thinner corneas, borderline topography, and higher refractive errors.Methods. Eligible patients first underwent SMILE procedure for correction of myopic refractive error. Following the removal of lenticule, 0.25% riboflavin in saline was injected into the interface and allowed to diffuse for 60 seconds. Finally, eye was exposed to UV-A radiation of 45 mW/cm2for 75 seconds through the cap. Total energy delivered was 3.4 J/cm2.Results. 40 eyes of 20 patients with mean age of 26.75 ± 5.99 years were treated. Mean follow-up was 12 months ± 28.12 days. Mean spherical equivalent (SE) was −5.02 ± 2.06 D preoperatively and −0.24 ± 0.18 D postoperatively. The mean central corneal thickness (CCT) and keratometry changed from 501 ± 25.90 µm to 415 ± 42.26 µm and 45.40 ± 1.40 D to 41.2 ± 2.75 D, respectively. Mean uncorrected visual acuity (UCVA) was 20/25 or better in all eyes. No eyes lost lines of corrected distant visual acuity (CDVA). There were no complications like haze, keratitis, ectasia, or regression.Conclusion. Based on the initial clinical outcome it appears that SMILE Xtra may be a safe and feasible modality to prevent corneal ectasia in susceptible individuals.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Rafic Antonios ◽  
Ali Dirani ◽  
Ali Fadlallah ◽  
Elias Chelala ◽  
Adib Hamade ◽  
...  

Purpose. To evaluate the long-term safety and clinical outcome of phakic Visian toric implantable collamer lens (ICL) insertion after corneal collagen cross-linking (CXL) in progressive keratoconus.Methods. This was a retrospective study of 30 eyes (19 patients), with progressive keratoconus, who underwent sequential CXL followed by Visian toric ICL implantation after 6 months.Results. At baseline, 6 eyes had stage I, 14 eyes stage II, and 10 eyes stage III keratoconus graded by Amsler-Krumeich classification. At 6 months after CXL, onlyK(steep) andK(max) decreased significantly from baseline, with no change in visual acuity or refraction. Flattening in keratometric readings was stable thereafter. There was significant improvement in mean uncorrected distance visual acuity (1.57 ± 0.56 to 0.17 ± 0.06 logMAR,P<0.001) and mean corrected distance visual acuity (0.17 ± 0.08 to 0.11 ± 0.05 logMAR,P<0.001) at 12 months after ICL implantation that was maintained at the 2-year follow-up. Mean cylinder power and mean spherical equivalent (SE) also decreased significantly after ICL implantation. A small hyperopic shift in SE (+0.25 D) was observed at 2 years that did not alter visual outcomes.Conclusions. Visian toric ICL implantation following CXL is an effective option for improving visual acuity in patients with keratoconus up to 2 years.


Author(s):  
Igor Kaiserman ◽  
Lily Karmona ◽  
Tzahi Sela ◽  
Oz Franco ◽  
Avi Shoshani ◽  
...  

ABSTRACT Purpose In this article, we present the results of eight eyes of patients who underwent combined same-day partial topography-guided surface ablation followed by accelerated collagen cross-linking (CXL) procedure at Care-Vision Laser Centers to achieve stabilization of corneal ectasia and enhance visual rehabilitation in keratoconus. Materials and methods A retrospective nonrandomized review of 8 eyes of 6 patients who underwent the Athens Protocol for progressive keratoconus. Each patient underwent topography-guided ablation followed by CXL procedure. Follow-up Follow-up was done on day 1, day 7, and then at 1, 3, 6, and 12 months. Results There was a rapid and significant improvement in uncorrected visual acuity and best-corrected visual acuity in 100% eyes, a reduction of keratometric values, and symmetry between vertical hemimeridians. Topographic evaluation showed a marked improvement in irregularity. There were no signs of keratoconic progression noted in any of the eyes on last follow-up. No adverse events were reported in any patient. Conclusion Simultaneous surface ablation + CXL seems to be a promising treatment capable of offering patients functional vision and halting progression of the disorder. Precis Simultaneous topography-guided custom ablation treatment and photorefractive keratectomy with CXL offers keratoconic patients intolerant to contact lenses both stabilization of the cornea and improved functional vision with spectacles correction. How to cite this article Karmona L, Sela T, Franco O, Shoshani A, Munzer G, Kaiserman I. Simultaneous Topography-guided Surface Ablation with Collagen Cross-linking for Keratoconus. Int J Kerat Ect Cor Dis 2016;5(2):71-76.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
A. M. Sherif ◽  
M. A. Ammar ◽  
Y. S. Mostafa ◽  
S. A. Gamal Eldin ◽  
A. A. Osman

Purpose.To evaluate effectiveness of simultaneous topography-guided photorefractive keratectomy and corneal collagen cross-linking in mild and moderate keratoconus.Methods. Prospective nonrandomized interventional study including 20 eyes of 14 patients with grade 1-2 keratoconus that underwent topography-guided PRK using a Custom Ablation Transition Zone (CATz) profile with 0.02% MMC application immediately followed by standard 3 mw/cm2UVA collagen cross-linking. Maximum ablation depth did not exceed 58 μm. Follow-up period: 12 months.Results.Progressive statistically significant improvement of UCVA from0.83±0.37logMAR preoperative, reaching0.25±0.26logMAR at 12 months (P<0.001). Preoperative BCVA (0.27±0.31logMAR) showed a progressive improvement reaching0.08±0.12logMAR at 12 months (P=0.02). MeanKmax reduced from48.9±2.8to45.4±3.1 D at 12 months (P<0.001), meanKmin reduced from45.9±2.8 D to44.1±3.2 D at 12 months (P<0.003), mean keratometric asymmetry reduced from3.01±2.03 D to1.25±1.2 D at 12 months (P<0.001). The safety index was 1.39 at 12 months and efficacy index 0.97 at 12 months.Conclusion. Combined topography-guided PRK and corneal collagen cross-linking are a safe and effective option in the management of mild and moderate keratoconus.Precis. To our knowledge, this is the first published study on the use of the CATz ablation system on the Nidek Quest excimer laser platform combined with conventional cross-linking in the management of mild keratoconus.


2020 ◽  
Vol 148 (1-2) ◽  
pp. 70-75 ◽  
Author(s):  
Svetlana Stanojlovic ◽  
Vedrana Pejin ◽  
Tanja Kalezic ◽  
Jelica Pantelic ◽  
Borivoje Savic

Introduction/Objective. The aim of this study was to report visual, refractive, and tomographic outcomes of corneal collagen cross-linking (CXL) in pediatric keratoconus. Methods. This retrospective study included 17 eyes of 12 patients with progressive keratoconus who underwent epithelium-off CXL at the age ? 18 years. Following data were analyzed at baseline and postoperatively at one, three, six, nine, 12 months for all the patients, and annually where available: uncorrected distant visual acuity (UDVA) and best spectacle-corrected distant visual acuity (CDVA), refraction and corneal tomography. Results. Mean UDVA improved significantly from 0.52 ? 0.38 at baseline to 0.24 ? 0.29 logarithm of minimum angle resolution (log MAR) at one year (p = 0.011) and remained stable at two-year follow-up (0.21 ? 0.34 log MAR). Mean CDVA was 0.15 ? 0.21 at baseline and 0.06 ? 0.13 log MAR at one year (p = 0.248). Maximum keratometry showed a significant flattening of 1.30 ? 1.99 D (p = 0.011) after a year and remained stable two years after CXL. Minimum keratometry significantly decreased with a mean change of 1.34 ? 1.37 (p = 0.001). Mean reduction of corneal thickness after CXL was 55.35 ? 64.42 ?m (P=0.003). After a year, seven (42%) eyes showed Kmax regression, nine (53%) stabilization, and one (5%) progression. Conclusion. In our study CXL effectively prevented progression of keratoconus in 95% of pediatric patients after a year, while improving UDVA and keratometry values. One patient with eye rubbing behavior showed signs of keratoconus progression after CXL treatment.


2019 ◽  
pp. 112067211988787 ◽  
Author(s):  
Indra Prasad Sharma ◽  
Ramendra Bakshi ◽  
Monica Chaudhry

Aim: The aim of this study was to assess and compare the visual, refractive, and topographic outcomes of keratoconic eyes treated with corneal collagen cross-linking combined with and without same day intrastromal corneal ring segment over the first 12 months. Methods: This prospective randomized study analyzed 38 eyes of 30 consecutive keratoconus patients aged 26.21 ± 6.97 (range = 15–41) years. A total of 20 eyes were treated with collagen cross-linking alone, and 18 eyes underwent collagen cross-linking combined with simultaneous femtosecond laser-assisted intrastromal corneal ring segment. Visual acuity, manifest refraction, and corneal topography (using a rotating Scheimpflug topographer) were assessed and compared between the two groups at baseline, 6, and 12 months. Results: On an average follow-up duration of 12.2 ± 0.50 (range = 11–13) months, both collagen cross-linking alone and collagen cross-linking with simultaneous intrastromal corneal ring segment implantation were effective. However, collagen cross-linking plus intrastromal corneal ring segment resulted in an additional improvement of uncorrected distance visual acuity of 0.16 (95% confidence interval = 0.01 to 0.32) logarithm of the minimum angle of resolution units (p = 0.035), cylindrical power by 1.16 D (95% confidence interval = 0.25 to 2.06, p = 0.014), and spherical equivalent by 1.40 D (95% confidence interval = −2.71 to −0.08, p = 0.038) at 1 year. During the study period, no serious intraoperative or postoperative complications were noted in either group. Conclusion: One-year follow-up results suggest that collagen cross-linking with simultaneously combined intrastromal corneal ring segment implantation could yield an additive visual and refractive outcome. The combined procedure is safe and merits consideration for the treatment of progressive keratoconus to achieve better visual rehabilitation.


2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Arleta Waszczykowska ◽  
Piotr Jurowski

Purpose. To evaluate the long-term results of accelerated corneal cross-linking (CXL) in patients with progressive keratoconus.Methods. Sixteen patients underwent accelerated CXL at 6 mW/cm2for 15 minutes in one eye. The follow-up visits were scheduled on 7 days, 14 days, and 3, 12, and 24 months after the treatment.Results. There were no significant differences (P>0.05) between preoperative and 2-year postoperative mean values, respectively, in terms of uncorrected visual acuity, best spectacle-corrected visual acuity, maximum keratometryKmax⁡, minimum keratometryKmin⁡, corneal astigmatism, and corneal eccentricity index. We noted a significant flattening of the cornea in 18.7% of patients with a higher preoperativeKmax⁡value (>50 D) and its steepening in patients with a lowerKmax⁡value (<50 D) (6.25%). There was no significant difference in the central corneal thickness and the apical corneal thickness preoperatively and 2 years postoperatively. The mean demarcation line depth was282±11 μm. Persistent corneal haze was noted in 25% of patients.Conclusions. Accelerated CXL appears to be a relatively effective procedure for the treatment of keratoconus in 2-year follow-up.