Keratoconic Bi-aspheric Contact Lenses

Author(s):  
Ariela Gordon-Shaag ◽  
Philip Fine ◽  
Liat Gantz ◽  
Arige Gideon-Abousaid ◽  
Gad Serero

ABSTRACT Aim This observational clinical case series examined patients with keratoconus (KC) fit with keratoconic bi-aspheric (KBA) lenses to assess visual acuity (VA), wavefront aberrations, physiological fitting, subjective comfort, and manufacturer's fitting guidelines. Materials and methods Seven adult patients (11 eyes, four females, mean age: 34.15 ± 14.12) with nipple cones from the Hadassah Academic College contact lens clinic (Jerusalem, Israel) were fit with KBA lenses by modifying the initial base curve (BC) to obtain an acceptable physiological fit. The uncorrected and corrected distance (D) and near (N) Snellen VA and the ocular wavefront measurements, and responses to a self-administered five-point scale questionnaire were compared after 2 weeks of wear using paired two-tailed t-test or Mann-Whitney U test, as appropriate. Results Visual acuity and total root mean square (RMS) improved significantly with the lenses (DVAuncorrected = 0.04 ± 0.02, DVAcorrected = 0.66 ± 0. 22, NVAuncorrected = 0.34 ± 0.30, NVAcorrected = 0.95 ± 0.12). Subjects reported an average of 7.0 ± 2.7 hours of wear daily, with good scores in visual stability, satisfaction with VA and quality of vision, improvement of mood and quality of life, and low scores in foreign body sensation, pain, red eye, and itching during wear, and difficulty with lens removal. An average of two BC modifications from the diagnostic lens were necessary (0.16 mm steeper in nine eyes, 0.27 mm flatter in two eyes). Conclusion Keratoconic bi-aspheric lenses can provide 7 hours of comfortable wear, significantly improved VA and total RMS aberrations, alongside subjective satisfaction. Base curve modifications can be reduced by fitting a diagnostic lens 0.75 mm steeper than the flattest keratometry reading. How to cite this article Gantz L, Gordon-Shaag A, Gideon-Abousaid A, Serero G, Fine P. Keratoconic Bi-aspheric Contact Lenses. Int J Kerat Ect Cor Dis 2016;5(3):132-138.

2021 ◽  
Vol 20 (4) ◽  
pp. 135-139
Author(s):  
Dong Ho Lee

Prescribing rigid gas-permeable (RGP) lenses involves a series of processes that determine the most appropriate final lens through the trial use of test lenses based on the results of slit lamp microscopy, measuring refraction and corneal curvature, and corneal topography. The final prescription is reached by judging the dynamic lens movement, adequacy of the tear layer around the lens, corrected vision, and quality of vision. Various problems are encountered soon after prescribing lenses, including foreign body sensation, tear hypersecretion, decreased visual acuity, blurring, visual acuity change, redness, dryness, sudden pain, lens centering, and lens fallout. Here, we examine these problems and how to solve them.


Author(s):  
Jose M González-Méijome ◽  
Sofia Claudia Peixoto-de-Matos ◽  
Antonio Queiros ◽  
Jorge M Jorge ◽  
Alberto Diaz-Rey

ABSTRACT Purpose To evaluate optical quality and visual function in keratoconus patients corrected with RGP contact lenses and a novel special design of silicone hydrogel contact lens. Materials and methods Twelve eyes of six patients with keratoconus were enrolled to experience a new soft contact lens (Soft-K) for keratoconus made of a silicone-hydrogel material and the outcomes were compared to the performance with gas permeable lenses and spectacles. The three situations were compared for monocular and binocular high (100%) and low contrast (10%) ETDRS LogMAR visual acuity and contrast sensitivity function (CSF). Results On average, there was an improvement of more than two lines in visual acuity over spectacle correction and this is statistically significant for both gas permeable (GP) and Soft-K lens (p < 0.001). Visual acuity was not significantly different between GP and Soft-K lens for high contrast acuity but was slightly higher with GP lens for low contrast under binocular conditions. Monocular CSF showed a marked improvement with the Soft-K lens and GP, compared to spectacles correction, particularly for medium and high frequencies; conversely. Conclusion Soft-K silicone hydrogel soft contact lens produces a clinical and statistically significant improvement in visual acuity and contrast sensitivity function over spectacle correction. How to cite this article González-Méijome JM, Peixoto-de- Matos SC, Queiros A, Jorge JM, Diaz-Rey A. Quality of Vision with Spectacles, Special Silicone Hydrogel and Gas Permeable Contact Lenses in Keratoconic Patients. Int J Kerat Ect Cor Dis 2013;2(2):56-59.


2021 ◽  
Vol 18 (3) ◽  
pp. 518-526
Author(s):  
E. P. Tarutta ◽  
S. V. Milash ◽  
M. V. Epishina

Purpose: to study the effect of bifocal soft contact lens (BSCL) with an ADD of 4 diopters on peripheral refraction (PR), optical and ergonomic eye parameters in children with myopia.Patients and methods. 26 patients (52 eyes) with myopia –3.09 ± 1.13 diopters at the age of 10.04 ± 1.5 years without correction and with correction by BSCL Prima BIO Bi-focal ( Okay Vision Retail, Russia). All patients underwent a horizontal and vertical PR study on an open field autorefractometer Grand Seiko WAM-5500 (Japan), wavefront aberrations were studied on OPD-Scan III aberrometer (Nidek, Japan), contrast sensitivity under mesopic conditions were studied on a Mesotest 2 instrument (Oculus, Germany) and visual productivity was studied using test tables.Results. The visual acuity of the distance with a BSCL correction of 0.98 ± 0.04 did not differ (p = 0.26) from the maximum visual acuity corrected by spherocylindrical glasses of 0.99 ± 0.04. BSCL induces myopic defocus in all peripheral zones, with a maximum value of 15° and a sharp decrease of 30°. Peripheral myopic defocus induced by the lens at a horizontal and vertical angle of 15 degrees did not depend on the initial degree of myopia. BSCL increases the total RMS from 0.07 ± 0.02 μm to 0.19 ± 0.07 μm in the 3 mm zone (p < 0.01) and from 0.27 ± 0.09 μm to 1.18 ± 0, 23 μm in the 6 mm zone (p < 0.01), mainly due to an increase in spherical aberration from –0.0005 ± 0.006 μm to 0.06 ± 0.01 μm (p < 0.01) and from 0.01 ± 0.09 μm to 0.58 ± 0.14 μm (p < 0.01) in the 3 mm and 6 mm zones, respectively. An increase in the overall RMS in BSCL reduces the quality of eye optics and contrast sensitivity under mesopic conditions, but does not impair visual productivity.Conclusion. BSCLs with a high ADD of 4 diopters are capable of inducing significant myopic peripheral defocus due to the induction of spherical aberration, while maintaining high visual acuity and not changing ophthalmic ergonomics, which makes them a pathogenetically substantiated method for correcting myopia and preventing its progression in children and adolescents.


The Eye ◽  
2020 ◽  
Vol 22 (130) ◽  
pp. 36-43
Author(s):  
Gulnara Andrienko

Corneal topography is the main method for assessing the regularity of the surface of the cornea. Corneal irregularity leads to a deterioration in its refractive properties and a decrease in the quality of vision. Learning the basics of corneal topography will help determine the choice of a color map for a specific situation, as well as understand and analyze the data associated with these maps. This article describes the main types of topographic maps, various patterns of corneal shape in normal and pathological conditions and how to use the data obtained to design and fit contact lenses. Despite the fact that images may vary depending on topographers used, the information presented in this article is universal.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El-Hennawi ◽  
Ehab F. Mossallam

Abstract Background This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification. Results The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was − 0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 ft) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 ft) and mean Uncorrected near visual acuity (UCNVA) was 0.87 ± 0.20 decimal (snellen equivalent 23 ft). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence. Trial registration Registration number and date: NCT04465279 on July 10, 2020.


2019 ◽  
Author(s):  
Fei Xia ◽  
Yang Shen ◽  
Tian Han ◽  
Jing Zhao ◽  
Hai-Peng Xu ◽  
...  

Abstract Background To investigate the long-term corneal stability and wavefront aberrations after small incision lenticule extraction (SMILE) for moderate and high myopia.Methods Prospective, non-consecutive case series. A total of 26 patients (42 eyes) who underwent SMILE from May 2010 to March 2013 at the Fudan University Eye and ENT Hospital (Shanghai, China) were enrolled. The periods of follow-up were 1 month, 1 year, 5 years and 7 years after surgery. The routine eye examinations included uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), manifest refraction and corneal topography.Results All surgeries were executed without any complications. At the final visit, a UDVA of 20/20 or better was achieved in 42 eyes (100%), 21 eyes (50%) exhibited no change in CDVA. 15 eyes (36%) gained one line, 6 eyes (14%) gained two lines, and no eyes lost CDVA lines. 93% and 100% of eyes were within ±0.5 D and ±1.00 D of the target refraction, respectively. A mean refractive regression of -0.17 D was observed between 1 month and 7 years postoperatively. Mean corneal front curvature (KMF) were significantly increased between pre- and post-SMILE surgery (P<0.0001). Higher-order aberrations (HOAs) and vertical coma were significantly increased after SMILE compared to those measured before surgery (all P<0.001). There were no significant differences in horizontal coma, trefoil and spherical aberration between pre- and post-SMILE surgery (all P>0.05).Conclusions SMILE is an effective, safe and stable procedure for myopia correction, with relatively constant corneal stability and wavefront aberrations.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Maria L. Salvetat ◽  
Marco Zeppieri ◽  
Flavia Miani ◽  
Paolo Brusini

Purpose. To compare the higher-order aberrations (HOAs) due to the anterior and posterior corneal surfaces in patients that underwent either Descemet-stripping-automated-endothelial-keratoplasty (DSAEK) or penetrating keratoplasty (PK) for endothelial dysfunction and age-matched controls. Methods. This retrospective, observational, case series included 28 patients after PK, 30 patients after DSAEK, and 30 healthy controls. A Scheimpflug imaging system was used to assess the HOAs due to the anterior and posterior corneal surfaces at 4 mm and 6 mm optical zones. Total, 3rd and 4th order HOAs were considered. Intra- and intergroup differences were assessed using the Friedman and the Kruskal-Wallis tests, respectively; paired comparisons were performed using Duncan's multiple range test. Results. Total, 3rd and 4th order HOAs due to both corneal surfaces at 4 mm and 6 mm optical zones were significantly higher in the PK group, intermediate in the DSAEK group, and lower in controls (). The most important HOAs components in both PK and DSAEK groups were trefoil and coma from the anterior corneal surface () and trefoil from the posterior corneal surface (). Conclusions. The optical quality of both corneal surfaces appeared significantly higher after DSAEK than after PK, which can increase the postoperative patient's quality of vision and satisfaction.


Sign in / Sign up

Export Citation Format

Share Document