corneal surface
Recently Published Documents


TOTAL DOCUMENTS

515
(FIVE YEARS 125)

H-INDEX

39
(FIVE YEARS 3)

2022 ◽  
Vol 11 (2) ◽  
pp. 329
Author(s):  
Marta P. Wiącek ◽  
Monika Kuśmierz-Wojtasik ◽  
Bogna Kowalska ◽  
Anna Machalińska

Background: Both pterygium ingrowth and excision determine alterations in corneal topography. The aim of this study was to evaluate the influence of pterygium removal combined with conjunctival autografts in addition to the use of human fibrin tissue glue on changes in corneal parameters as measured by 3-D swept-source anterior segment optical coherence tomography (AS-OCT) imaging. Methods: Sixteen eyes (16 patients) with pterygium that qualified for surgical treatment were enrolled in this study. Eye examination, slit lamp, and 3-D AS-OCT (CASIA 2) assessment were performed before the surgery and 7 days, 1 month, and 6 months after pterygium excision. Topographic parameters of both anterior and posterior surfaces of the cornea were analysed at each follow-up visit. Results: The gradual decrease in total astigmatism power from preoperative median 2.75 (6.15) D to 1.2 (1.1) D at 6-month follow-up (p = 0.034) was noted from the day 7 visit. Values were strongly influenced by variations of anterior cornea astigmatism. In contrast, a gradual total HOA reduction at the 1-month (from median 0.79 (1.3) D to 0.44 (0.27) D; p = 0.038) and at 6-month visits (0.25 (0.09); p = 0.001) was observed. Similarly, values were strongly influenced by variations of the anterior. Additionally, total average keratometry values increased from preoperative 44.05 (2.25) D to 44.6 (1.9) (p = 0.043) 1 month after the surgery. Conclusions: Significant steepening of the anterior cornea and a reduction in both astigmatism and HOA were observed after pterygium excision. The anterior corneal surface was an essential component of the total postoperative corneal topography values. Three-dimensional swept-source AS-OCT imaging seems to be a valuable tool for monitoring both the progression of the disease and postoperative effects in pterygium eyes.


2021 ◽  
Vol 44 (4) ◽  
pp. E46-54
Author(s):  
Michael Deng ◽  
Lina Lan ◽  
Tianhui Chen ◽  
Min Zhang ◽  
Jiahui Chen ◽  
...  

Purpose: To evaluate the distribution of the posterior-anterior corneal radius ratio (B/F ratio; posterior corneal radius/anterior corneal radius) in patients without corneal abnormalities, and to investigate which parameters affect this ratio. Methods: Five thousand eyes from 5,000 patients who underwent cataract surgery were recruited to this study. We explored the linear relationship between B/F ratio and 13 variables using Principal Component-Multivariate Linear Regression Analysis. Results: The B/F ratio was negatively correlated with the difference between simulated keratometry (SimK) and true net power (TNP), central corneal thickness, spherical aberration (SA), and posterior corneal astigmatism and positively correlated with posterior corneal radius, corneal posterior surface, axial length (AL) and anterior corneal radius. Several variables (central corneal thickness, difference between SimK and TNP and asphericity coefficient (Q-value) of the posterior corneal surface) had the highest loading on the final score. B/F ratio reflects the refractive state and anatomical structure of the cornea: thus, higher B/F ratios were associated with larger posterior corneal surface curvature radius, longer axial length, thinner central corneal thickness, lower high order aberrations of the cornea and SA, and the numerical difference between simK and TNP gradually reduced. In clinical practice, for patients with lower B/F ratio, special care should be taken in the choice of system used for intraocular lens (IOL) measurements.


2021 ◽  
Vol 20 (4) ◽  
pp. 140-143
Author(s):  
Kyong Jin Cho

The use of contact lenses for correcting refraction, suppressing myopia progression, and cosmetic purposes is increasing steadily. Contact lenses have various effects on the corneal surface and corneal infection can occur following obstruction of tear flow, micro-damage to corneal epithelial cells, corneal hypoxia, changes in corneal immunity, and exposure to contaminants. When a patient who used to wear contact lenses presents with keratitis, it is important to distinguish whether it is an infection; if it is an infection, it is important to find the causative strain and promptly treat it appropriately. Since improper lens care is related to infection, appropriate patient education is necessary, and the risk of contact lens infection should be reduced through regular ophthalmic examinations.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Yuan Wu ◽  
Shuhan Wang ◽  
Guiqin Wang ◽  
Shaozhen Zhao ◽  
Ruihua Wei ◽  
...  

Objective. To compare the corneal asphericity and higher-order aberrations (HOAs) of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) with Smart Pulse Technology (SPT) assisted transepithelial photorefractive keratectomy (Trans-PRK) for myopia and myopic astigmatism correction. Methods. This prospective study analyzed 88 eyes of 44 patients treated with FS-LASIK and 64 eyes of 32 patients treated with Trans-PRK. All eyes had low to moderate myopia with or without astigmatism (spherical equivalent (SE) <−6.00 diopters). The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), SE, asphericity (Q value) of the anterior corneal surface, index of surface variance (ISV), corneal higher-order aberrations (HOAs), vertical coma (Z3−1), horizontal coma (Z31), and spherical aberration (Z40) over a 6 mm diameter central corneal zone diameter were evaluated preoperatively and 1, 3, and 6 months postoperatively. Results. At 6 months, the UDVA and SE were −0.14 ± 0.06 and 0.33 ± 0.33D in FS-LASIK and −0.15 ± 0.06 and 0.35 ± 0.37D in Trans-PRK. There was no difference between the two groups in the postoperative UDVA and SE ( P > 0.05 ). After FS-LASIK and Trans-PRK, the Q values in the 6, 7, 8, and 9 mm zones and ISV of the anterior corneal surface significantly increased ( P < 0.001 ). At 1, 3, and 6 months after surgery, corneal HOA, Z3-1, Z31, and Z40 in both groups were significantly increased compared with those before surgery, with statistically significant differences ( P < 0.001 ). At 1, 3, and 6 months after surgery, the Z3−1 of the Trans-PRK group was significantly lower than that of the FS-LASIK group ( P < 0.001 ). ΔHOA and ΔZ40 were dramatically correlated with the ΔQ value for both FS-LASIK and Trans-PRK procedures. The ΔQ was significantly correlated with the preoperative SE, AD, and AD/CCT after both two procedures (all P < 0.001 ). Conclusions. Both FS-LASIK and Trans-PRK caused the anterior corneal surface to become flatter, and the morphology of the corneal surface was irregular. Corneal HOAs were significantly increased after the two procedures. Trans-PRK using SPT introduced less corneal vertical coma than FS-LASIK. Corneal asphericity changes contributed to the corneal aberrations changes following FS-LASIK and Trans-PRK.


2021 ◽  
Vol 8 (12) ◽  
Author(s):  
Ziying Ran ◽  
Joshua Moore ◽  
Fan Jiang ◽  
Hongmei Guo ◽  
Ashkan Eliasy ◽  
...  

The aim of the study was to develop an automatic segmentation approach to optical coherence tomography (OCT) images and to investigate the changes in epithelial and stromal thickness profile and radius of curvature after the use of orthokeratology (Ortho-K) contact lenses. A total of 45 right eyes from 52 participants were monitored before, and after one month of, uninterrupted overnight Ortho-K lens wear. The tomography of their right eyes was obtained using optical OCT and rotating Scheimpflug imaging (OCULUS Pentacam). A custom-built MATLAB code for automatic segmentation of corneal OCT images was created and used to assess changes in epithelial thickness, stromal thickness, corneal and stromal profiles and radii of curvature before, and after one month of, uninterrupted overnight wear of Ortho-K lenses. In the central area (0–2 mm diameter), the epithelium thinned by 12.8 ± 6.0 µm (23.8% on average, p < 0.01) after one month of Ortho-K lens wear. In the paracentral area (2–5 mm diameter), the epithelium thinned nasally and temporally (by 2.4 ± 5.9 µm, 4.5% on average, p = 0.031). The stroma thickness increased in the central area (by 4.8 ± 16.1 µm, p = 0.005). The radius of curvature of the central corneal anterior surface increased by 0.24 ± 0.26 mm (3.1%, p < 0.01) along the horizontal meridian and by 0.34 ± 0.18 mm (4.2%, p < 0.01) along the vertical meridian. There were no significant changes in the anterior and posterior stromal radius of curvature. This study introduced a new method to automatically detect the anterior corneal surface, the epithelial posterior surface and the posterior corneal surface in OCT scans. Overnight wear of Ortho-K lenses caused thinning of the central corneal epithelium. The anterior corneal surface became flattered while the anterior and posterior surfaces of the stroma did not undergo significant changes. The results are consistent with the changes reported in previous studies. The reduction in myopic refractive error caused by Ortho-K lens wear was mainly due to changes in corneal epithelium thickness profile.


2021 ◽  
pp. 112067212110637
Author(s):  
Rania S Elkitkat ◽  
Yasser Rifay ◽  
Hesham M Gharieb ◽  
Hossam Eldin A Ziada

Purpose To determine the normative and the cut-off values of various indices available in the MS 39 Anterior Segment Optical Coherence Tomography (MS-39 AS-OCT) for keratoconus (KC) diagnosis, and to detect the accuracy of the variable available parameters. Methods This cross sectional observational study was conducted at Dr Rifay Ophthalmology Center, Rabat, Morocco, on 172 eyes with KC (group 1) and 248 eyes of healthy controls (group 2). Participants were screened using MS-39 AS-OCT (CSO, Firenze, Italy). The investigated indices included: keratometric indices, pachymetric indices, elevation indices, Keratoconus Summary Indices (KSI), aberration indices, and epithelial mapping evaluation. Results Most of the studied indices were significantly different between both groups (P value <0.001). Twenty two indices had Area Under the Receiver Operating Curve (AUROC) values >0.950, eight of which were from the KSI. The indices with the highest AUROC values were: Root Mean Square (RMS) for the front corneal surface at 6 mm circle (AUROC = 0.996, and best cut-off >1.69 with sensitivity of 97.67% and specificity of 97.98%) and RMS per unit of area for the front surface at 6 mm circle (AUROC = 0.996, and best cut-off >0.06 with sensitivity of 97.67% and specificity of 97.98%). Epithelial thickness-derived metrics were not among the parameters with the highest accuracy. Conclusions This study presented the mean and the cut-off values for a plethora of parameters available in the MS-39 AS-OCT. The results of this study show that MS-39 AS-OCT is a valuable equipment for diagnosing keratoconic corneas, with a high accuracy detected for many parameters.


Molecules ◽  
2021 ◽  
Vol 26 (23) ◽  
pp. 7246
Author(s):  
Antonia Di Mola ◽  
Francesco Ferdinando Summa ◽  
Patrizia Oliva ◽  
Francesco Lelj ◽  
Stefano Remiddi ◽  
...  

The properties of mixtures of two polysaccharides, arabinogalactan (AG) and hyaluronic acid (HA), were investigated in solution by the measurement of diffusion coefficients D of water protons by DOSY (Diffusion Ordered SpectroscopY), by the determination of viscosity and by the investigation of the affinity of a small molecule molecular probe versus AG/HA mixtures in the presence of bovine submaxillary mucin (BSM) by 1HNMR spectroscopy. Enhanced mucoadhesive properties, decreased mobility of water and decreased viscosity were observed at the increase of AG/HA ratio and of total concentration of AG. This unusual combination of properties can lead to more effective and long-lasting hydration of certain tissues (inflamed skin, dry eye corneal surface, etc.) and can be useful in the preparation of new formulations of cosmetics and of drug release systems, with the advantage of reducing the viscosity of the solutions.


2021 ◽  
Vol 8 ◽  
Author(s):  
Qian Wang ◽  
Fei Yu ◽  
Ziqing Feng ◽  
Weihua Li ◽  
Naiyang Li ◽  
...  

Purpose: To evaluate corneal elevation changes in patients with allergic conjunctivitis (AC) and to analyze their correlations with ocular allergy signs and corneal biomechanical alterations.Methods: Thirty patients (30 eyes) with AC and twenty normal subjects (20 eyes) were included in this prospective study. All participants underwent a complete ocular examination, including corneal tomography by Pentacam and corneal biomechanics evaluation by Corvis ST. AC patients were evaluated for their eye rubbing frequency and ocular allergic signs.Results: The elevation at the thinnest location (TE) and the central location (CE), the elevation difference at the thinnest location (TED) and the central location (CED), and the mean value of elevation difference in the central 4 mm zoom (MED) of both the anterior and posterior corneal surface were significantly higher in the AC group than in the normal group (p &lt; 0.05 for all). In AC patients, only anterior corneal elevation parameters were positively correlated with eye rubbing frequency and ocular allergy sign severity (p &lt; 0.05 for all), while the tomography and biomechanical index (TBI) was positively correlated with the elevation parameters of both the anterior and posterior corneal surfaces (p &lt; 0.05 for all).Conclusion: AC patients carry an increased risk of corneal ectasia. Posterior corneal elevation parameters are sensitive and reliable predictors of keratoconus (KC) risk in AC patients.Clinical Trial Registration:https://clinicaltrials.gov/ct2/show/NCT04299399, identifier [NCT04299399].


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Dariusz Dobrowolski ◽  
Boguslawa Orzechowska-Wylegala ◽  
Bogumil Wowra ◽  
Ewa Wróblewska-Czajka ◽  
Maria Grolik ◽  
...  

Purpose. To analyse the recurrence of superficial neovascularisation after previous corneal surface reconstruction with cultivated corneal epithelial cells. Materials and Methods. Forty-eight eyes underwent autologous transplantation of cultivated corneal epithelium to treat partial or total limbal stem cell deficiency caused by chemical or thermal injury. The carrier for the epithelial sheets was a denuded amniotic membrane. Follow-up was conducted for up to 120 months. Recurrent revascularisation (measured in terms of clock hours affected) was evaluated with slit-lamp examination and the support of confocal microscopy. Results. During the long-term observation, only 7 eyes had stable epithelia with no neovascularisation from the conjunctiva. Nineteen eyes developed pathologic vessels in 1 quadrant, with additional 4 eyes developing them in 2 quadrants. Twelve patients developed subtotal or total conjunctivalisation of the corneal surface. They were referred for second cultivated epithelium transplantation (3 patients), allogenic keratolimbal transplantation (7 patients), or keratoprosthesis (2 patients). Six patients withdrew consent. The use of confocal scans of up to 100 µm in resolution enabled the detection of pathologic microvasculature originating from the conjunctiva and the exclusion of stromal vascular ingrowth. Conclusions. Local ingrowth of the conjunctiva is a common complication after the transplantation of cultivated epithelial cells. Severe and progressive vascularisation inevitably leads to graft failure. However, if local ingrowth stops before reaching the central cornea, the treatment even with this complication can be considered a success.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7636
Author(s):  
Alejandra Consejo ◽  
Arwa Fathy ◽  
Bernardo T. Lopes ◽  
Renato Ambrósio ◽  
Jr. Abass

To quantify the effect of levelling the corneal surface around the optical axis on the calculated values of corneal asphericity when conic and biconic models are used to fit the anterior corneal surface. This cross-sectional study starts with a mathematical simulation proving the concept of the effect that the eye’s tilt has on the corneal asphericity calculation. Spherical, conic and biconic models are considered and compared. Further, corneal asphericity is analysed in the eyes of 177 healthy participants aged 35.4 ± 15.2. The optical axis was determined using an optimization procedure via the Levenberg–Marquardt nonlinear least-squares algorithm, before fitting the corneal surface to spherical, conic and biconic models. The influence of pupil size (aperture radii of 1.5, 3.0, 4.0 and 5.0 mm) on corneal radius and asphericity was also analysed. In computer simulations, eye tilt caused an increase in the apical radii of the surface with the increase of the tilt angle in both positive and negative directions and aperture radii in all models. Fitting the cornea to spherical models did not show a significant difference between the raw-measured corneal surfaces and the levelled surfaces for right and left eyes. When the conic models were fitted to the cornea, changes in the radii of the cornea among the raw-measured corneal surfaces’ data and levelled data were not significant; however, significant differences were recorded in the asphericity of the anterior surfaces at radii of aperture 1.5 mm (p < 0.01). With the biconic model, the posterior surfaces recorded significant asphericity differences at aperture radii of 1.5 mm, 3 mm, 4 mm and 5 mm (p = 0.01, p < 0.01, p < 0.01 & p < 0.01, respectively) in the nasal temporal direction of right eyes and left eyes (p < 0.01, p < 0.01, p < 0.01 & p < 0.01, respectively). In the superior–inferior direction, significant changes were only noticed at aperture radii of 1.5 mm for both right and left eyes (p = 0.05, p < 0.01). Estimation of human corneal asphericity from topography or tomography data using conic and biconic models of corneas are affected by eyes’ natural tilt. In contrast, the apical radii of the cornea are less affected. Using corneal asphericity in certain applications such as fitting contact lenses, corneal implant design, planning for refractive surgery and mathematical modelling when a geometrical centre of the eye is needed should be implemented with caution.