scholarly journals First Clinical Impressions on the Integrated Corneal Tomography and Corneal Deformation with Scheimpflug Imaging

Author(s):  
Jorge S Haddad ◽  
Eliza Barnwell ◽  
Karolinne M Rocha ◽  
George O Waring IV ◽  
Renato Ambrosio Jr

ABSTRACT The purpose of this study is to report the preliminary findings and the retrospective clinical impressions of the integrated corneal tomography and corneal deformation parameters with a dynamic ultra-high-speed Scheimpflug camera equipped with a noncontact tonometer. Twelve eyes of six patients were evaluated by the Scheimpflug imaging system of the Pentacam HR and Corvis ST (OCULUS Optikgeräte GmbH, Wetzlar, Germany) devices. The parameters used were the Belin/Ambrósio deviation (BAD-D) and Corvis biomechanical index (CBI), as well as the recently published tomographic and biomechanical index (TBI), combined with a detailed clinical data and evaluation of normal eyes and patients with different stages of corneal ectasia. How to cite this article Haddad JS, Barnwell E, Rocha KM, Waring IV GO, Ambrosio Jr R. First Clinical Impressions on the Integrated Corneal Tomography and Corneal Deformation with Scheimpflug Imaging. Int J Kerat Ect Cor Dis 2017;6(2):101-109.

2017 ◽  
Vol 33 (9) ◽  
pp. 625-631 ◽  
Author(s):  
Ryan N. Mercer ◽  
George O. Waring ◽  
Cynthia J. Roberts ◽  
Vishal Jhanji ◽  
Yumeng Wang ◽  
...  

Author(s):  
Isaac Ramos ◽  
Marcella Q Salomão ◽  
Fernando F Correia

ABSTRACT Purpose To test the ability of metrics derived from corneal response to noncontact tonometry (NCT) to distinguish between normal and ectatic cases. Materials and methods The prototype of CorVis ST (Oculus, Wetzlar, Germany) was used for assessing corneal biomechanical response using ultra-high-speed 8 mm horizontal Scheimpflug photography, taking 4,330 frames per second during NCT. Patients were stratified based on clinical data, including rotating Scheimpflug corneal tomography (Oculus Pentacam HR). Biomechanical data from one eye randomly selected of 177 patients with normal corneas (N) and from 79 patients with bilateral keratoconus (KC) were investigated. Group forme fruste keratoconus (FFKC) was composed of 20 eyes with normal topographic patterns from cases with ectasia detected in the fellow eye. Group keratoconus suspect (KCS) had 16 eyes from 16 patients with topographic patterns suspicious of KC but documented stability over 3 years and normal tomographic findings. A combination of deformation parameters using linear regression analysis (Prototype Factor 1, pF1) was created by the BrAIn (Brazilian Artificial Intelligence on Corneal Tomography and Biomechanics) study group in order to provide the best possible separation of KC and normals. Results Statistical significant differences were found for N × KC for several parameters, including first and second applanation times, deformation amplitude, and maximal concavity radius (Mann–Whitney, p < 0.001). However, the areas under the receiver operating characteristic curves (AUC) were lower than 0.90. The pF1 had AUC of 0.945 (IC 0.909–0.97; sensitivity = 87.3% and specificity = 89.3%). The pF1 had statistically significant differences between the ectatic (KC and FFKC) and nonectatic groups (N and KCS) (p < 0.05, Kruskall–Wallis Test with post hoc Dunn's test). Conclusion Corneal deformation response analysis by ultra- high-speed 8 mm horizontal Scheimpflug photography provides relevant data for distinguishing ectatic and nonectatic corneas but cannot be used independently to detect KC. This data may be integrated with corneal tomography data for enhancing sensitivity and specificity for screening ectasia. How to cite this article Salomão MQ, Correia FF, Ramos I, Luz A, Ambrósio R Jr. Corneal Deformation Response with Dynamic Ultra-high-speed Scheimpflug Imaging for Detecting Ectatic Corneas. Int J Kerat Ect Cor Dis 2016;5(1):1-5.


2021 ◽  
Vol 48 (1) ◽  
pp. 14-19
Author(s):  
Maria A. Henriquez ◽  
Isabel Gomez ◽  
Maythe Camino-Quezada ◽  
Luis Izquierdo ◽  
José Chauca ◽  
...  

2013 ◽  
Vol 76 (4) ◽  
pp. 229-232 ◽  
Author(s):  
Bruno Freitas Valbon ◽  
Renato Ambrósio-Jr. ◽  
Bruno Machado Fontes ◽  
Milton Ruiz Alves

2014 ◽  
Vol 129 (S1) ◽  
pp. S45-S50 ◽  
Author(s):  
J H Kim ◽  
J Rimmer ◽  
N Mrad ◽  
S Ahmadzada ◽  
R J Harvey

AbstractObjective:This study investigated the effect of Betadine on ciliated human respiratory epithelial cells.Methods:Epithelial cells from human sinonasal mucosa were cultured at the air–liquid interface. The cultures were tested with Hanks' balanced salt solution containing 10 mM HEPES (control), 100 µM ATP (positive control), 5 per cent Betadine or 10 per cent Betadine (clinical dose). Ciliary beat frequency was analysed using a high-speed camera on a computer imaging system.Results:Undiluted 10 per cent Betadine (n = 6) decreased the proportion of actively beating cilia over 1 minute (p < 0.01). Ciliary beat frequency decreased from 11.15 ± 4.64 Hz to no detectable activity. The result was similar with 5 per cent Betadine (n = 7), with no significant difference compared with the 10 per cent solution findings.Conclusion:Betadine, at either 5 and 10 per cent, was ciliotoxic. Caution should be applied to the use of topical Betadine solution on the respiratory mucosal surface.


2013 ◽  
Vol 72 (2) ◽  
pp. 99-102 ◽  
Author(s):  
Renato Ambrósio Jr ◽  
Isaac Ramos ◽  
Allan Luz ◽  
Fernando Correa Faria ◽  
Andreas Steinmueller ◽  
...  