scholarly journals Comparison of Proseal Laryngeal Mask Airway with the I-Gel Supraglottic Airway During the Bailey Manoeuvre in Adult Patients Undergoing Elective Surgery

Author(s):  
Nishant Kalra ◽  
◽  
Akhilesh Gupta ◽  
Rajesh Sood ◽  
Mohandeep Kaur ◽  
...  
2018 ◽  
Vol 5 (3) ◽  
pp. 415-418
Author(s):  
Saranjit Singh ◽  
◽  
Sapna Bansal ◽  
Rahul Midda ◽  
Dhanwant Kaur ◽  
...  

2004 ◽  
Vol 101 (2) ◽  
pp. 340-343 ◽  
Author(s):  
Shinichi Kihara ◽  
Joseph R. Brimacombe ◽  
Yuichi Yaguchi ◽  
Noriko Taguchi ◽  
Seiji Watanabe

Background The authors compared the manufacturer's weight-based formula (size 3 for weight < 50 kg, size 4 for weight 50-70 kg, and size 5 for weight > 70 kg) with a sex-based formula (size 4 for women and size 5 for men) for selecting the appropriate size of ProSeal laryngeal mask airway. Methods Two hundred thirty-seven healthy, anesthetized, paralyzed adult patients (American Society of Anesthesiologists physical status I or II; age, 18-80 yr) were randomly allocated for weight- or sex-based size selection. An experienced user inserted the ProSeal laryngeal mask airway with the digital technique. The following were compared: ease of insertion, oropharyngeal leak pressure, ease of ventilation, gas exchange, location of gas leak, anatomic position, mucosal injury, and postoperative pharyngolaryngeal problems. Intraoperative and postoperative data collection were unblinded and blinded, respectively. Results Ease of insertion, anatomic position, gas exchange, mucosal injury, and postoperative pharyngolaryngeal problems were similar between groups. For the sex-based group, larger ProSeal laryngeal mask airways were selected more frequently (P < 0.0001), oropharyngeal leak pressure (P = 0.02) was higher, leak volume (P = 0.004) and leak fraction (P = 0.007) were lower, and oropharyngeal leaks (P = 0.03) were detected less frequently. Conclusion Size selection for the ProSeal laryngeal mask airway is equally effective using the manufacturer's weight-based formula or the sex-based formula in healthy, anesthetized, paralyzed adult patients, but leakage of small volumes of air from the mouth occurs less frequently with the sex-based formula.


Author(s):  
Smita R. Engineer ◽  
Digant B. Jansari ◽  
Saumya Saxena ◽  
Rahul D. Patel

<p class="abstract"><strong>Background:</strong> Supraglottic airway devices have been widely used as an alternative to tracheal intubation during general anesthesia both in adults and children. This study was carried out to compare classical laryngeal mask airway (LMA) and i-gel, regarding ease of insertion, adequate placement of device, ability to maintain ETCO<sub>2</sub> and SPO<sub>2</sub>, perioperative hemodynamic parameters and intra operative and postoperative complication.</p><p class="abstract"><strong>Methods:</strong> This prospective, randomized clinical study was done on 100 patients of either sex, age between 5 to 60 years, ASA grade I-III who underwent different surgical procedures under general anesthesia in supine position. After giving premedication, induction of anesthesia was done with inj. Propofol 2-3 mg/kg and inj. Succnylcoline 1.5-2 mg/kg. In “sniffing air” position, airway was secured with either LMA or i-gel. An effective placement of device was checked by a square wave capnography, normal chest expansion, SPO<sub>2</sub> &gt;95%, and absence of audible leak. Patients were observed for time and ease of insertion, number of attempts, perioperative hemodynamic changes and complications.</p><p><strong>Results:</strong> No statistically significant difference was reported between both the groups, regarding heart rate, BP, SPO<sub>2</sub> and ETCO<sub>2</sub>. Duration of insertion was more in group LMA. Insertion was easy and was possible in first attempt in 88% of patients without much manipulation in group i-gel.</p><p><strong>Conclusions:</strong> I-gel is a better alternative supraglottic airway device than LMA in view of ease of insertion with minimal manipulations and minimal complications. Hemodynamic parameters, SPO<sub>2</sub> and ETCO<sub>2 </sub>were maintained in both the groups. </p>


Sign in / Sign up

Export Citation Format

Share Document