Analysis of Joint Behaviour in Vertical Bracings of Steel Frames for Multi-Storey Buildings

Author(s):  
A. A. Novoselov
Keyword(s):  
2011 ◽  
Vol 67 (5) ◽  
pp. 741-758 ◽  
Author(s):  
Concepción Díaz ◽  
Pascual Martí ◽  
Mariano Victoria ◽  
Osvaldo M. Querin
Keyword(s):  

2014 ◽  
Vol 13 (3) ◽  
pp. 267-274 ◽  
Author(s):  
Krzysztof Ostrowski ◽  
Aleksander Kozłowski

Rotation capacity is one of the joint parameters needed to be taken into account of the real joint behaviour in a global analysis. It has a special influence on the plastic design of steel frames. The results of the parametric study of the stiffened bolted end-plate beam-to-column connection have been presented in the paper. The main investigated parameters are: thickness of end plate “tp”, horizontal bolt spacing “w” and distance of the bolt to plate edge “cg1”. The analysis was performed with the use of finite element method, based on the numerical experiment plan.


Author(s):  
Marcos Henrique Bossardi Borges ◽  
Adelano Esposito ◽  
Herbert Gomes

1982 ◽  
Vol 315 (0) ◽  
pp. 48-60
Author(s):  
Tsuneyoshi NAKAMURA ◽  
Osamu OHTA ◽  
Koji UETANI

2020 ◽  
pp. 136943322097728
Author(s):  
Haoran Yu ◽  
Weibin Li

Reduced web section (RWS) connections and welded flange plate (WFP) connections can both effectively improve the seismic performance of a structure by moving plastic hinges to a predetermined location away from the column face. In this paper, two kinds of steel frames—with RWS connections and WFP connections—as well as different frames with welded unreinforced flange connections were studied through seismic fragility analysis. The numerical simulation was conducted by using multiscale FE modelling. Based on the incremental dynamic analysis and pushover analysis methods, probabilistic seismic demand analysis and seismic capability analysis were carried out, respectively. Finally, combined with the above analysis results, probabilistic seismic fragility analysis was conducted on the frame models. The results showed that the RWS connection and WFP connection (without double plates) have little influence on reducing the maximum inter-storey drift ratio under earthquake action. RWS connections slightly reduce the seismic capability in non-collapse stages and improve the seismic collapse resistance of a structure, which exhibits good structural ductility. WFP connections can comprehensively improve the seismic capability of a structure, but the seismic collapse resistance is worse than that of RWS connections when the structure has a large number of storeys. The frame with WFP connections has a lower failure probability at every seismic limit state, while the frame with RWS connections sacrifices some of its structural safety in non-collapse stages to reduce the collapse probability.


Sign in / Sign up

Export Citation Format

Share Document