scholarly journals The Effect of Noise Exposure on Signal to Noise Ratio Changes of Distortion Product Otoacoustic Emissions (DPOAE) Examination in Rattus Norvegicus

Author(s):  
Tengku Siti Hajar Haryuna ◽  
Susi Mulyana
2005 ◽  
Vol 48 (5) ◽  
pp. 1165-1186 ◽  
Author(s):  
Tracy S. Fitzgerald ◽  
Beth A. Prieve

Although many distortion-product otoacoustic emissions (DPOAEs) may be measured in the ear canal in response to 2 pure tone stimuli, the majority of clinical studies have focused exclusively on the DPOAE at the frequency 2f1-f2. This study investigated another DPOAE, 2f2-f1, in an attempt to determine the following: (a) the optimal stimulus parameters for its clinical measurement and (b) its utility in differentiating between normal-hearing and hearing-impaired ears at low-to-mid frequencies (≤2000 Hz) when measured either alone or in conjunction with the 2f1-f2 DPOAE. Two experiments were conducted. In Experiment 1, the effects of primary level, level separation, and frequency separation (f2/f1) on 2f2-f1 DPOAE level were evaluated in normal-hearing ears for low-to-mid f2 frequencies (700–2000 Hz). Moderately high-level primaries (60–70 dB SPL) presented at equal levels or with f2 slightly higher than f1 produced the highest 2f2-f1 DPOAE levels. When the f2/f1 ratio that produced the highest 2f2-f1 DPOAE levels was examined across participants, the mean optimal f2/f1 ratio across f2 frequencies and primary level separations was 1.08. In Experiment 2, the accuracy with which DPOAE level or signal-to-noise ratio identified hearing status at the f2 frequency as normal or impaired was evaluated using clinical decision analysis. The 2f2-f1 and 2f1-f2 DPOAEs were measured from both normal-hearing and hearing-impaired ears using 2 sets of stimulus parameters: (a) the traditional parameters for measuring the 2f1-f2 DPOAE (f2/f1 = 1.22; L1, L2 = 65, 55 dB SPL) and (b) the new parameters that were deemed optimal for the 2f2-f1 DPOAE in Experiment 1 (f2/f1 = 1.073, L1 and L2 = 65 dB SPL). Identification of hearing status using 2f2-f1 DPOAE level and signal-to-noise ratio was more accurate when the new stimulus parameters were used compared with the results achieved when the 2f2-f1 DPOAE was recorded using the traditional parameters. However, identification of hearing status was less accurate for the 2f2-f1 DPOAE measured using the new parameters than for the 2f1-f2 DPOAE measured using the traditional parameters. No statistically significant improvements in test performance were achieved when the information from the 2 DPOAEs was combined, either by summing the DPOAE levels or by using logistic regression analysis.


2004 ◽  
Vol 194 (1-2) ◽  
pp. 87-96 ◽  
Author(s):  
Ana E Vázquez ◽  
Ana M Jimenez ◽  
Glen K Martin ◽  
Anne E Luebke ◽  
Brenda L Lonsbury-Martin

2004 ◽  
Vol 194 (1-2) ◽  
pp. 109-117 ◽  
Author(s):  
Claudia Candreia ◽  
Glen K Martin ◽  
Barden B Stagner ◽  
Brenda L Lonsbury-Martin

2015 ◽  
Vol 129 (12) ◽  
pp. 1174-1181 ◽  
Author(s):  
N Wooles ◽  
M Mulheran ◽  
P Bray ◽  
M Brewster ◽  
A R Banerjee

AbstractObjective:To examine whether distortion product otoacoustic emissions can serve as a replacement for pure tone audiometry in longitudinal screening for occupational noise exposure related auditory deficit.Methods:A retrospective review was conducted of pure tone audiometry and distortion product otoacoustic emission data obtained sequentially during mandatory screening of brickyard workers (n = 16). Individual pure tone audiometry thresholds were compared with distortion product otoacoustic emission amplitudes, and a correlation of these measurements was conducted.Results:Pure tone audiometry threshold elevation was identified in 13 out of 16 workers. When distortion product otoacoustic emission amplitudes were compared with pure tone audiometry thresholds at matched frequencies, no evidence of a robust relationship was apparent. Seven out of 16 workers had substantial distortion product otoacoustic emissions with elevated pure tone audiometry thresholds.Conclusion:No clinically relevant predictive relationship between distortion product otoacoustic emission amplitude and pure tone audiometry threshold was apparent. These results do not support the replacement of pure tone audiometry with distortion product otoacoustic emissions in screening. Distortion product otoacoustic emissions at frequencies associated with elevated pure tone audiometry thresholds are evidence of intact outer hair cell function, suggesting that sites distinct from these contribute to auditory deficit following ototrauma.


2021 ◽  
pp. 1-16
Author(s):  
Naomi F. Bramhall ◽  
Garnett P. McMillan ◽  
Amy N. Mashburn

Purpose Distortion product otoacoustic emissions (DPOAEs) and audiometric thresholds have been used to account for the impacts of subclinical outer hair cell (OHC) dysfunction on auditory perception and measures of auditory physiology. However, the relationship between DPOAEs and the audiogram is unclear. This study investigated this relationship by determining how well DPOAE levels can predict the audiogram among individuals with clinically normal hearing. Additionally, the impacts of age, noise exposure, and the perception of tinnitus on the ability of DPOAE levels to predict the audiogram were evaluated. Method Suprathreshold DPOAE levels from 1 to 10 kHz and pure-tone thresholds from 0.25 to 16 kHz were measured in 366 ears from 194 young adults (19–35 years old) with clinically normal audiograms and middle ear function. The measured DPOAE levels at all frequencies were used to predict pure-tone thresholds at each frequency. Participants were grouped by age, self-reported noise exposure/Veteran status, and self-report of tinnitus. Results Including DPOAE levels in the pure-tone threshold prediction model improved threshold predictions at all frequencies from 0.25 to 16 kHz compared with a model based only on sample mean pure-tone thresholds, but these improvements were modest. DPOAE levels for f 2 frequencies of 4 and 5 kHz were particularly influential in predicting pure-tone thresholds above 4 kHz. However, prediction accuracy varied based on participant characteristics. On average, predicted pure-tone thresholds were better than measured thresholds among Veterans, individuals with tinnitus, and the oldest age group. Conclusions These results indicate a complex relationship between DPOAE levels and the audiogram. Underestimation of pure-tone thresholds for some groups suggests that additional factors other than OHC damage may impact thresholds among individuals within these categories. These findings suggest that DPOAE levels and pure-tone thresholds may differ in terms of how well they reflect subclinical OHC dysfunction. Supplemental Material https://doi.org/10.23641/asha.13564745


Sign in / Sign up

Export Citation Format

Share Document