Simultaneous method development and Validation by HPLC for Capecitabine and Oxaliplatin in mucoadhesive microspheres containing capsules

Author(s):  
Krishna Patel ◽  
Dipti Patel

A simple, specific and accurate reversed-phase high performance liquid chromatographic method was developed for the simultaneous determination of Capecitabine and Oxaliplatin, using a Hypersil BDS C18, 150x4.6 mm, 5μ column and a mobile phase composed of 10mM dipotassium hydrogen phosphate+0.1% TEA pH 5.0: Acetonitrile (50:50%v/v). The flow rate was 1.0 ml/min, and the detection wavelength was 245 nm. The injection volume was 20 μL. The retention times of Capecitabine and Oxaliplatin found 4.29 min and 5.52 min, respectively. Linearity was established for Capecitabine and Oxaliplatin in the range of 60-210μg/ml and 20-70 μg/ml, respectively. The percentage recoveries of Capecitabine and Oxaliplatin found to be in the range of 99.1-101.5% and 97.9-99.7 %, respectively. The proposed method validated for precision, accuracy, linearity range, and robustness. This method can successfully be employed for simultaneous quantitative analysis of Capecitabine and Oxaliplatin in the capsule.

Author(s):  
Kuntal Mukherjee ◽  
S. T. Narenderan ◽  
B. Babu ◽  
Survi Mishra ◽  
S. N. Meyyanathan

A simple, sensitive and rapid high performance liquid chromatographic method has been developed for the determination of Propofol. The main focus of the method was to determine Propofol in solution form as well as in marketed formulation. Chromatographic separation was achieved on Inertsil ODS-3V column (250mm x 4.6mm; 5µm) with a mobile phase consisting of methanol: water (85:15), with a flow rate of 1.0ml/min (UV detection at 270nm). Linearity was observed over the concentration range of 10-110µg/ml with a regression equation y=88048x + 44524 and having a regression value (R2) of 0.999. The LOD and LOQ values found to be 10ng and 100ng, respectively. No changes found in ruggedness and robustness studies. The percentage of recovery was found to be 95.25% to 101.81%. Validation studies revealed that the method was specific, accurate, precise, reliable, robust, reproducible and suitable for the quantitative analysis in its pharmaceutical formulations.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


Sign in / Sign up

Export Citation Format

Share Document