Seismic Control of Slender Liquid Storage Tank Isolated by Variable Radius Friction Pendulum System under Far Fault Ground Motions

2019 ◽  
Vol 11 (12-SPECIAL ISSUE) ◽  
pp. 906-914
Author(s):  
Smeet Faldu ◽  
Rambha Thakur ◽  
Madhu Vanti
2016 ◽  
Vol 24 (7) ◽  
pp. 1264-1282 ◽  
Author(s):  
Saman Bagheri ◽  
Mostafa Farajian

There are several methods to reduce the seismic damages in liquid storage tanks. One of these methods is to use passive control devices, in particular seismic base isolators. Among the different base isolation systems, the Friction Pendulum System (FPS) whose period does not depend on the weight of the system is more appropriate for isolation of liquid storage tanks. The aim of this paper is to investigate the effects of peak ground acceleration (PGA) and pulselike characteristics of earthquakes on the seismic behavior of steel liquid storage tanks base isolated by FPS bearings. In addition, impact effects of the slider with the side retainer are investigated, as well as effects of tank aspect ratio, isolation period and friction coefficient. The obtained results of tanks with different aspect ratios indicate that the responses get more reduced due to isolation under far-field ground motions compared to near-fault ground motions. It is also seen that the response of a base isolated tank is affected when contact takes place with the side retainer of the FPS.


2020 ◽  
Vol 25 (1) ◽  
pp. 27-40
Author(s):  
Aruna Rawat ◽  
Vasant Matsagar ◽  
A. K. Nagpal

A seismic analysis of ground-supported, three-dimensional (3-D) rigid-base steel cylindrical liquid storage tank is investigated, using a coupled acoustic-structural finite element (FE) method for fluid-structure interaction (FSI). In this method, the contained liquid in the tank is modelled using acoustic elements and the cylindrical tank is modelled using shell elements. The impulsive and convective terms are estimated separately by using the appropriate boundary conditions on the free surface of the liquid. The convergence and validation studies of the proposed FE model are conducted by comparing the results reported in the literature. The parametric studies are performed for rigid and flexible tanks for the varying slenderness of the open roof tanks. The sloshing displacement and base shear time history responses are evaluated for the 3-D tanks subjected to harmonic unidirectional ground motions. Further, the results are compared with the commonly used two and three lumped-mass models of the tank. Moreover, the seismic response quantities of the tank subjected simultaneously to the bi-directional horizontal components of earthquake ground motion are also investigated using the 3-D FE model, and the response quantities are compared with the lumped-mass models. The results obtained from the 3-D FE model and lumped-mass model are in close agreement. The average percentage difference in the 3-D FE and lumped-mass models for maximum sloshing displacement prediction is 15 percent to 20 percent and that for the base shear is about 4 to 10 percent, in the case of the uni-directional harmonic ground motions. It is concluded that the sloshing displacement is not affected by the tank flexibility, but the impulsive hydrodynamic pressure and the impulsive component of the base shear increases with the tank flexibility.


Sign in / Sign up

Export Citation Format

Share Document