Angle stable plate osteosynthesis for non-union of rib fractures

10.5580/9f9 ◽  
2007 ◽  
Vol 6 (2) ◽  
Injury ◽  
2015 ◽  
Vol 46 ◽  
pp. S99-S103 ◽  
Author(s):  
Sebastian Kuhn ◽  
Julia Greenfield ◽  
Charlotte Arand ◽  
Andrey Jarmolaew ◽  
Philipp Appelmann ◽  
...  

2018 ◽  
Vol 156 (06) ◽  
pp. 646-652 ◽  
Author(s):  
Matthias Königshausen ◽  
Valentin Rausch ◽  
Eileen Mempel ◽  
Alexander von Glinski ◽  
Christopher Ull ◽  
...  

Abstract Introduction Bilateral acute proximal humerus fractures are rare. There are no data available about these bilateral injuries. The aim of the study was to analyse bilateral proximal humerus fractures retrospectively in terms of incidence, complications and revisions. Methods All bilateral proximal humerus fractures were evaluated retrospectively using the institutionʼs database, with the focus on cause of the injury, fracture severity and the clinical course compared to published information on monolateral proximal humerus fractures. Bilateral posterior dislocation fractures were excluded, because these fractures are a separate entity. Results Between 2005 and 2016, n = 17 patients were primarily treated within our hospital for an acute proximal humerus fracture on both sides (n = 12 female, n = 5 male, average age: 68 years; overall 34 proximal humerus fractures). The general trauma mechanism was a fall on both arms (82% [18% polytrauma]). There were 65% displaced 3-/4-part proximal humerus fractures. Angle-stable plate osteosynthesis was performed predominantly (64%), followed by fracture prosthesis (18%; tension wiring: 3%; non-operatively: 15%). Overall, n = 10 patients (59%) or n = 18 (53%) proximal humerus fractures developed a complication, primarily with loss of reduction or implant loosening (44%). In n = 14 (78%) of the complications further operations were necessary. Alcohol abuse was increasingly found in 29% of the cases within the bilateral patient cohort compared to patients with monolateral fractures. Conclusion Bilateral proximal humerus fractures are mainly associated with comminuted displaced fractures and a higher complication rate in comparison to monolateral fractures after surgical treatment.


Author(s):  
Sabrina Sandriesser ◽  
Stefan Förch ◽  
Edgar Mayr ◽  
Falk Schrödl ◽  
Christian von Rüden ◽  
...  

Abstract Purpose Distal tibial fractures generally require post-operative weight-bearing restrictions. Especially geriatric patients are unable to follow these recommendations. To increase post-operative implant stability and enable early weight-bearing, augmentation of the primary osteosynthesis by cerclage is desirable. The purpose of this study was to identify the stabilizing effects of a supplemental cable cerclage following plate fixation of distal tibial spiral fractures compared to solitary plate osteosynthesis. Methods In eight synthetic tibiae, a reproducible spiral fracture (AO/OTA 42-A1.1c) was stabilized by angle stable plate fixation. Each specimen was statically loaded under combined axial and torsional loads to simulate partial (200 N, 2 Nm) and full (750 N, 7 Nm) weight-bearing. Tests were repeated with supplemental cable cerclage looped around the fracture zone. In a subsequent stepwise increased dynamic load scenario, construct stiffness and interfragmentary movements were analyzed. Results With supplemental cable cerclage, construct stiffness almost tripled compared to solitary plate osteosynthesis (2882 ± 739 N/mm vs. 983 ± 355 N/mm; p < 0.001). Under full weight-bearing static loads, a supplemental cerclage revealed reduced axial (− 55%; p = 0.001) and shear movement (− 83%; p < 0.001), and also lowered shear movement (− 42%; p = 0.001) compared to a solitary plate under partial weight-bearing. Under dynamic loads supplemental cerclage significantly reduced axial (p = 0.005) as well as shear movements (p < 0.001). Conclusion Supplemental cable cerclage significantly increases fixation stiffness and reduces shear movement in distal tibial spiral fractures. This stabilizing effect enables from a biomechanical point of view immediate mobilization without any weight-bearing restrictions, which may improve the quality of care of orthopedic patients and may trigger a change towards early weight-bearing regimes, especially geriatric patients would benefit from.


2017 ◽  
Vol 17 (2) ◽  
pp. 18-22
Author(s):  
Nabees Man Singh Pradhan ◽  
JA Khan ◽  
B Acharya ◽  
S Shrestha ◽  
R Tamrakar ◽  
...  

Introduction: Distal tibial fractures present as a major challenge for the orthopedic trauma surgeons. Most non-operative treatments result in non-union or malunion and needs prolonged immobilization of the knee and ankle joints, with resulting stiffness. Open reduction and internal fixation as well as external fixation has high rate of infection and non-union. Minimally Invasive Plate Osteosynthesis has been shown to have a better outcome and has been the procedure of choice in most distal tibial fractures since the introduction of the locking compression plate. The objective of the study is to review the outcome of Minimally Invasive Percutaneous Osteosynthesis (MIPO) in unstable distal tibial fractures.Methods: Charts of patients who underwent MIPO from the year 2008 to 2013 for unstable distal tibial fractures over five years at Patan Hospital and Om Hospital were reviewed. All displaced closed fractures and Gustillo Anderson Type I and II fractures were included in the study. Plates consisted of the anatomically contoured 4.5 mm LCP and 3.5 mm LCP-Pilon form plate. A simple uniplanar external fixator was used to retain the reduction till the plate was inserted and secured with locking screws. The outcome of MIPO in distal tibial fractures were followed up and evaluated.  Clinical and radiological assessments were performed at 6 weeks, and at 3, 6, 9, 12 and 24 months.Results: Of the 75 patients (45 male, 30 female) age ranging from 19 to 70 years (mean 47 years), 5 patients were lost to follow-up. 28 patients at 3 months, 32 at 6 months, and 8 at 9 months met the criteria for a healed fracture. Two patients required autologous bone grafting at 9 months for non-union ultimately resulting in the fracture union at 16 months. There was one malunion attributable to the loss of reduction during plate fixation. There were no deep infections, no soft tissue complications and no failures of fixation. The cause of fracture were RTA (n=35), fall from height (n=9), twisting of ankle as a result of fall from standing height (n=22), and others (n=11). The mean time for surgery from the time of injury was 5 (range, 2 to 14) days; the mean hospital stay was 10 (range, 7 to 21) days.Conclusion: MIPO is an effective treatment for closed, unstable fractures of the distal tibia, avoiding the complications associated with more traditional methods of internal fixation and/or external fixation.Journal of Society of Surgeons of NepalVol. 17, No. 2, 2014, Page: 7-11