scholarly journals Development of simplified soil pollution evaluation method using luminous bacteria for petroleum hydrocarbons 3

2020 ◽  
Vol 62 (4) ◽  
pp. 573-587
Author(s):  
Hajime SUGITA ◽  
Takeshi KOMAI
2016 ◽  
Vol 58 (4) ◽  
pp. 417-430
Author(s):  
Hajime SUGITA ◽  
Takeshi KOMAI ◽  
Yukari IMOTO ◽  
Junko HARA

2013 ◽  
Vol 55 (4) ◽  
pp. 329-347
Author(s):  
Hajime SUGITA ◽  
Takeshi KOMAI ◽  
Yukari IMOTO ◽  
Junko HARA ◽  
Hiroyuki IMAIZUMI

2020 ◽  
Vol 65 (2) ◽  
pp. 57-64
Author(s):  
Loredana Mihaela Şeute ◽  

The level of pollution with petroleum compounds was evaluated in Suplacu de Barcău area based on the assessment of total petroleum hydrocarbons (TPH) concentrations in soil. As source of contamination, one active and another inactive petroleum extraction wells were chosen, and the concentrations were determined by fluorescence spectrometry. The results indicated alarming exceedances of the intervention thresholds, especially in the area where the activity is stopped, thus indicating long-term accumulation of pollutant and persistence in soil. Keywords: petroleum hydrocarbons, soil pollution, TPH, fluorescence spectrometry


2013 ◽  
Vol 130 ◽  
pp. 72-79 ◽  
Author(s):  
J. Pinedo ◽  
R. Ibáñez ◽  
J.P.A. Lijzen ◽  
Á. Irabien

2019 ◽  
Vol 11 (2) ◽  
pp. 142-155
Author(s):  
Evgenia GURKOVA ◽  
◽  
Olga AYUNOVA ◽  
Artem VOLOBAEV ◽  
Olga KALNAYA ◽  
...  

Author(s):  
T. Oikawa ◽  
H. Kosugi ◽  
F. Hosokawa ◽  
D. Shindo ◽  
M. Kersker

Evaluation of the resolution of the Imaging Plate (IP) has been attempted by some methods. An evaluation method for IP resolution, which is not influenced by hard X-rays at higher accelerating voltages, was proposed previously by the present authors. This method, however, requires truoblesome experimental preperations partly because specially synthesized hematite was used as a specimen, and partly because a special shape of the specimen was used as a standard image. In this paper, a convenient evaluation method which is not infuenced by the specimen shape and image direction, is newly proposed. In this method, phase contrast images of thin amorphous film are used.Several diffraction rings are obtained by the Fourier transformation of a phase contrast image of thin amorphous film, taken at a large under focus. The rings show the spatial-frequency spectrum corresponding to the phase contrast transfer function (PCTF). The envelope function is obtained by connecting the peak intensities of the rings. The evelope function is offten used for evaluation of the instrument, because the function shows the performance of the electron microscope (EM).